• Title/Summary/Keyword: hydrogen refueling

Search Result 104, Processing Time 0.018 seconds

A Study on the Safety Enhancement of Hydrogen Tube Trailer (수소운송설비 안전성 강화 방안 고찰)

  • Woo-Il, Park;Yeong-Hun, Kim;In-Woo, Lee;Seung-Kyu, Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.59-64
    • /
    • 2022
  • Currently, 787 hydrogen tube trailer are in operation as of the end of October 2022, and a maximum of 340 kg is transported in a Type 1 seamless container at a pressure of up to 200 bar. The current safety management system and facility management are in good condition, but the system and facility structure improvement are needed to strengthen safety. Accordingly, this paper simulated and analyzed an accident case that occurred on the Daejeon-Dangjin highway on December 28, 2021 during the process of expanding the supply and operation of hydrogen tube trailer according to the hydrogen energy activation policy. Based on the results, suggestions were made on how to improve the safety of hydrogen tube trailer.

3D Explosion Analyses of Hydrogen Refueling Station Structure Using Portable LiDAR Scanner and AUTODYN (휴대형 라이다 스캐너와 AUTODYN를 이용한 수소 충전소 구조물의 3차원 폭발해석)

  • Baluch, Khaqan;Shin, Chanhwi;Cho, Yongdon;Cho, Sangho
    • Explosives and Blasting
    • /
    • v.40 no.3
    • /
    • pp.19-32
    • /
    • 2022
  • Hydrogen is a fuel having the highest energy compared with other common fuels. This means hydrogen is a clean energy source for the future. However, using hydrogen as a fuel has implication regarding carrier and storage issues, as hydrogen is highly inflammable and unstable gas susceptible to explosion. Explosions resulting from hydrogen-air mixtures have already been encountered and well documented in research experiments. However, there are still large gaps in this research field as the use of numerical tools and field experiments are required to fully understand the safety measures necessary to prevent hydrogen explosions. The purpose of this present study is to develop and simulate 3D numerical modelling of an existing hydrogen gas station in Jeonju by using handheld LiDAR and Ansys AUTODYN, as well as the processing of point cloud scans and use of cloud dataset to develop FEM 3D meshed model for the numerical simulation to predict peak-over pressures. The results show that the Lidar scanning technique combined with the ANSYS AUTODYN can help to determine the safety distance and as well as construct, simulate and predict the peak over-pressures for hydrogen refueling station explosions.

Current Status of Hydrogen Consumption and Promotion Plan for the Deployment of Fuel Cell Bus in Changwon City (창원시 수소버스 운행에 따른 수소소비 현황 및 보급 활성화 방안)

  • KANG, BOO MIN;KANG, YOUNG TAEC;KIM, MIN WOO;LEE, SANG HYUN;PARK, MIN-JU;JEONG, CHANG-HOON;JEONG, DAE-WOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.479-484
    • /
    • 2019
  • Environmental problems were related to human life from second industrial revolution. Recently, peoples are interested in solving global warming problem and improving air quality. Therefore, we request for eco-friendly vehicles such as fuel cell electric vehicles using eco-friendly hydrogen energy. In order to reduce particulate matter in Korea, we have established a plan to promote the deployment of eco-friendly vehicles. In this paper, we analyzed the average monthly charging status and hydrogen consumption by introducing fuel cell bus.

A Study on the Metal Wire for Hoop Wrapping of Type 2 High Pressure Tank (Type 2 고압용기 권선용 금속선재에 관한 연구)

  • HAN, JINMOOK;CHOI, SOOKWANG;LEE, SUNGHEE;CHO, KYUNGCHUL;HWANG, CHULMIN;JUNG, YOUNGUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.338-346
    • /
    • 2019
  • During last years, hydrogen refueling infrastructure test and devices research for hydrogen station presented a significant growth consisting of the commercialization of fuel cell electric vehicles (FCEVs). However, we still have many challenges for making commercial hydrogen stations such as increased safety and cost reduction. This study demonstrates the low cost hydrogen storage tank (type 2) and effective winding method for high pressure hydrogen storage. We use numerical analysis to verify stress changes inside the wire according to the winding condition. Also liner size, winding wire size and wire tension were studied for the safety and cost down. Results show that the stress of winding wire decreased with increased winding angle and increased the liner diameter. On the other hand, the stress of winding wire increased according to the increased wire thickness and tension.

Risk Assessment of High Pressure HCNG Refueling Station Explosion by Numerical Simulation (시내버스용 HCNG 고압가스 충전소의 폭발 위험성 해석)

  • Kang, Seung-Kyu;Kim, Young-Gu;Choi, Seul-Ki;Kwon, Jeong-Rak
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.113-113
    • /
    • 2014
  • This study has been conducted for evaluation of qualitative/quantitative risk of HCNG filling station. In case of fire explosion occurred because of hydrogen, CNG, and HCNG leaking on same conditions, maximum overpressure was measured as 30kPa for hydrogen, 3.5kPa for HCNG, and 0.4kPa for CNG. The overpressure of HCNG was measured 7.75 times higher than that of CNG, but it was only 11.7% compared with hydrogen. When the explosion was occurred, in case of hydrogen, the measured influential distance of overpressure was 59m and radiant heat was 75m. In case of CNG, influential distance of overpressure was 89m and radiant heat was 144m would be estimated. In case of 30% HCNG that was blended with hydrogen and CNG, influential distance of overpressure was 81m and radiant heat was 130m were measured. As the explosion occurred with the same sized container that had 350bar for hydrogen and 250bar of CNG and HCNG, the damage distance that explosive overpressure and radiant heat influenced CNG was seen as the highest. HCNG that was placed between CNG and hydrogen tended to be seen as more similar with CNG.

  • PDF

Optimization of Designing Barrier to Mitigate Hazardous Area in Hydrogen Refueling Stations (수소충전소 폭발위험장소 완화를 위한 확산차단벽 최적화 설계)

  • SEUNGHYO AN;SEHYEON OH;EUNHEE KIM;JUNSEO LEE;BYUNGCHOL MA
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.734-740
    • /
    • 2023
  • Hydrogen emphasis on safety management due to its high potential for accidents from wide explosive limits and low ignition energy. To prevent accidents, appropriate explosion-proof electrical equipment with installed to safe management of ignition sources. However, designing all facilities with explosion-proof structures can significantly increase costs and impose limitations. In this study, we optimize the barrier to effectively control the initial momentum in case of hydrogen release and form the control room as a non-hazardous area. We employed response surface method (RSM), the barrier distance, width and height of the barrier were set as variables. The Box-Behnken design method the selection of 15 cases, and FLACS assessed the presence of hazardous area. Analysis of variance (ANOVA) analysis resulting in an optimized barrier area. Through this methodology, the workplace can optimize the barrier according to the actual workplace conditions and classify reasonable hazardous area, which is believed to secure safety in hydrogen facilities and minimize economic burden.

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

A Study on Safety Improvement for Packaged Hydrogen Refueling Station by Risk Assessment (위험성 평가를 통한 패키지형 수소충전소 안전성 향상에 관한 연구)

  • KANG, SEUNGKYU;HUH, YUNSIL;MOON, JONGSAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.635-641
    • /
    • 2017
  • In this study, the components of packaged hydrogen filling station were analyzed and risk factors were examined. Risk scenarios were constructed and quantitative risk assessments were conducted through a general risk assessment program (phast/safeti 7.2). Through the risk assessment, the range of damage according to accident scenarios and the ranking that affects the damage according to the risk factors are listed, and scope of damage and countermeasures for risk reduction are provided. The quantitative risk assessment result of the packaged hydrogen filling station through this task will be used as the basic data for improving the safety of the packaged filling system and preparing safety standards.

Analysis of Flow Performance Factors According to Extreme Temperature Conditions of Hydrogen Inflow of FCEV Charging System Check Valve (FCEV 충전 시스템 체크밸브의 수소 유입 극한 온도 조건에 따른 유동 성능 인자 분석)

  • SEUNG HUN OH;HYUN KYU SUH
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.514-525
    • /
    • 2023
  • This study conducted numerical simulations with the purpose of analyzing the impact of variations in outlet pressure conditions under extreme temperature conditions on the fluid dynamics and performance of a check valve utilized in hydrogen refueling systems. Under the extreme temperature conditions, changes in outlet pressure conditions of the check valve were investigated to analyze velocity distributions, pressure distributions, and temperature distributions in the operational and connection regions. The analysis results indicated that changes in outlet pressure had a significant influence on the internal temperature variation of the check valve. Furthermore, due to density variations in the connection region caused by the cooling effect of excessively cooled hydrogen, a bias in the primary flow direction towards the lower part of the valve outlet was observed in the outlet area. Through a comparison of the results of the valve's inherent flow performance, represented by the flow coefficient, it was observed that when the pressure difference between the inlet and outlet was below 0.37 MPa, sufficient flow was not ensured.

Study on the Optimum Capacity Analysis for Hydrogen Fueling Station in Korea (국내 수소충전소의 적정 용량 분석)

  • HAN, JA-RYOUNG;PARK, JINMO;LEE, YOUNG CHUL;KIM, SANG MIN;JEON, SO HYUN;KIM, HYOUNG SIK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.649-656
    • /
    • 2017
  • At present, hydrogen is emerging as a future energy source based on environment-friendly aspect, creation of new industry, and enhancement of domestic energy security. In accordance with it, the world's leading automobile companies are focusing on the development and commercialization of hydrogen electric vehicle technology, and each country is strengthening its hydrogen fueling station deployment strategy for its own country. Furthermore, the supply of hydrogen fueling stations is actively promoting under national support. More than 500 hydrogen fueling stations are being constructed, operated and planned around the world. The introduction of hydrogen energy is also progressing in Korea, by announcing road-map to supply hydrogen electric vehicles and hydrogen fueling stations by year. However, there is insufficient discussion on the capacity of hydrogen fueling station in Korea. Therefore, this study suggests the optimum capacity of hydrogen fuelling station for domestic hydrogen economy.