• Title/Summary/Keyword: hydrogen generation

Search Result 805, Processing Time 0.023 seconds

Economic Analysis and Comparison between Low-Power and High-Power SOEC Systems (저출력 및 고출력 SOEC 시스템의 경제성 분석 비교)

  • TUANANH BUI;YOUNG SANG KIM;DONG KEUN LEE;KOOK YOUNG AHN;YONGGYUN BAE;SANG MIN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.707-714
    • /
    • 2022
  • Hydrogen production using solid oxide electrolysis cells (SOEC) is a promising technology because of its efficiency, cleanness, and scalability. Especially, high-power SOEC system has received a lot of attention from researchers. This study compared and analyzed the low-power and high-power SOEC system in term of economic. By using revenue requirement method, levelized cost of hydrogen (LCOH) was calculated for comparison. In addition, the sensitivity analysis was performed to determine the dependence of hydrogen cost on input variables. The results indicated that high-power SOEC system is superior to a low-power SOEC system. In the capital cost, the stack cost is dominant in both systems, but the electricity cost is the most contributed factor to the hydrogen cost. If the high-power SOEC system combines with a nuclear power plant, the hydrogen cost can reach 3.65 $/kg when the electricity cost is 3.28 ¢/kWh and the stack cost is assumed to be 574 $/kW.

Hydrogen Peroxide Generation of DSA for Electro-Fenton Reaction and Removal of Rhodamine B (Electro-Fenton 반응을 위한 불용성 전극의 과산화수소 생성과 Rhodamine B의 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.175-182
    • /
    • 2008
  • This study investigates the optimal conditions for electrogenerated hydrogen peroxide production and the application of the electro-Fenton process using DSA electrodes. The influences of parameters for the hydrogen peroxide generation such as electrode materials, electrolyte concentration, current, pH, air flow rate and electrode distance were investigated using a laboratory scale batch reactor. The relative performance for hydrogen peroxide generation of each of the six electrodes is : Ru-Sn-Ti > Ru-Sn-Sb > Ru > Ir > Pt > Sn-Sb. Optimum NaCl dosage, current and air flow rate were 2.0 g/l, 12.5 A and 2 l/min, respectively. When the pH is low, hydrogen peroxide concentration was high. Electrode distance dos not effect to a hydrogen peroxide generation. A complete color removal was obtained for RhB (200 mg/l) at the 8 min mark of the electro-Fenton process under optimum operation conditions of $Fe^{2+}$ 0.105 g/l and 5.0 A. The electro-Fenton process increased initial reaction and decreased final reaction time. However the effect was not high.

Effects of Co-P Catalysts on Hydrogen Generation Properties from Alkaline $NaBH_4$ Solution (알칼리 $NaBH_4$ 용액의 수소발생특성에 미치는 Co-P 촉매의 영향)

  • Cho, Keun-Woo;Kwon, Hyuk-Sang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.4
    • /
    • pp.379-385
    • /
    • 2005
  • Effects of Co and Co-P catalysts on the hydrolysis of alkaline $NaBH_4$ solution were investigated. Co and Co-P catalysts were prepared on Cu substrate by electroplating. Hydrogen generation rate of Co-P catalyst was much faster than that of Co catalyst, demonstrating that Co-P had higher intrinsic catalytic activity for the hydrolysis of $NaBH_4$ than Co. Hydrogen generation properties of Co-P catalysts largely depended on cathodic current density and electroplating time because they influenced on the P concentration of the Co-P catalysts. Maximum hydrogen generation rate of Co-P catalyst was 1066 ml/min.g-catalyst in 1 wt.% NaOH + 10 wt.% $NaBH_4$ solution at $20^{\circ}C$, which was obtained at cathodic current density of $0.01\;A/cm^2$ for 130 s.

The Effects of Nozzle Shapes and Pressures on Boundary Layer Flashback of Hydrogen-Air Combustor (수소 전소용 연소 노즐 형상과 연소실 압력이 경계층 역화에 미치는 영향)

  • WON JUNE LEE;JEONGJAE HWANG;HAN SEOK KIM;KYUNGWOOK MIN;MIN KUK KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.776-785
    • /
    • 2022
  • Hydrogen combustion in modern gas-turbine engine is the cutting edge technology as carbon-free energy conversion system. Flashback of hydrogen flame, however, is inevitable and critical specially for premixed hydrogen combustion. Therefore, this experimental investigation is conducted to understand flashback phenomenon in premixed hydrogen combustion. In order to investigate flashback characteristics in premixed hydrogen (H2)/air flame, we focus on pressure conditions and nozzle shapes. In general, quenching distance reduces as pressure of combustion chamber increases, causing flashback from boundary layer near wall. The flashback regime for reference and modified candidate configurations can broadly appear with increasing combustion chamber pressure. The later one can improve flashback-resist by compensating flow velocity at wall. Also, improved wall flow velocity profile of suggested contraction nozzle prevents entire flashback but causes local flashback at nozzle exit.

A Study on the Efficiency of Hydrogen-Oxygen Mixture Gas Generation Stack (수소-산소 혼합가스 발생 스택의 효율 연구)

  • Lee, Sang-Ho;Moon, Il-Sik;Kim, Chang-Hee;Kang, Kyoung-Soo;Park, Chu-Sik;Bae, Ki-Kwang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.409-417
    • /
    • 2006
  • The characteristics of hydrogen-oxygen mixture gas generation stack was experimentally studied in terms of efficiency. For this purpose, the mixture gas generation stack was fabricated by connecting 7 cells in series following the Tero Ranta report. In order to avoid the instrument inaccuracy, all measuring equipments were re-tested and calibrated by Korea Laboratory Accreditation Scheme (KOLAS) certified laboratories. Since the amount of produced gas is most crucial in determining the efficiency, two gas collecting methods such as bottle trap method and wet gas meter method were adopted. From the experimental results, it was found that both KOH fume and steam evaporated along with hydrogen-oxygen mixture gas, and these by-product gases could cause the misestimation of the stack efficiency. The current, voltage, and energy efficiencies of the hydrogen-oxygen mixture gas generation stack was evaluated based upon the stack efficiency calculation method summarized in this work.

A study on the channel design of bipolar plate of electrolytic cell of hydrogen gas generation system by flow dynamic simulation (수소가스발생 장치의 전해조 분라판의 유로설계에 관한 전산모사 연구)

  • Jo, Hyeon-Hak;Jang, Bong-Jae;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.152-156
    • /
    • 2010
  • This study is focused on the channel design of bipolar plate in the electrode of hydrogen gas generator. The characteristics of hydrogen gas generation was studied in view of efficiency of hydrogen gas generation rate and a tendency of gas flow through the riv design of electrode. Since the flow rate of generated gas is the most crucial in determining the efficiency of hydrogen gas generator, we adopted the commercial analytical program of COMSOL $Multiphysics^{TM}$ to calculate the theoretical flow rate of hydrogen gas from the outlet of gas generator.

Study on Reduction of Curtailment of Renewable Generation based on Green Hydrogen Sector Coupling (그린수소 기반 섹터 커플링 통한 재생에너지 출력제한 경감효과 연구)

  • Jeon, Wooyoung;Kim, Jin-yi;Lee, Seongwoo
    • New & Renewable Energy
    • /
    • v.18 no.2
    • /
    • pp.50-59
    • /
    • 2022
  • The Korean government announced the "1st Basic Plan for the Transition to Hydrogen Economy" in 2021 and declared the establishment of a hydrogen industry ecosystem by 2040. To build a low-carbon power system, resources that can efficiently accommodate renewable energy are required, and green hydrogen is considered a potential solution. This study analyzed the economic feasibility of green hydrogen-based sector coupling to reduce curtailment of renewable generation in the Jeju power system by 2025 under the scenario of with or without HVDC#3. The result showed that HVDC#3 significantly reduced the frequency of curtailment from 16.1% to 3.0%. In addition, green hydrogen-based sector coupling was an economically feasible option as result showed an IRR of 4.86% when HVDC#3 was connected and 11.45% when it was not under the condition of achieving 50% curtailment reduction. This study shows that the higher the level of renewable energy deployment, the more delayed the HVDC connection between Jeju and the main land, and the lower the SMP, the more economically feasible the green hydrogen-based sector coupling is. Furthermore, this study suggests that the policy goal of completely reducing curtailment is not economically efficient.

Ammonia-fueled Solid Oxide Fuel Cell Recirculation Systems for Power Generation (암모니아 활용 고체산화물 연료전지 재순환 발전 시스템)

  • JIN YOUNG PARK;THAI-QUYEN QUACH;JINSUN KIM;YONGGYUN BAE;DONGKEUN LEE;YOUNGSANG KIM;SUNYOUP LEE;YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.40-47
    • /
    • 2024
  • Ammonia is drawing attention as carbon free fuel due to its ease of storage and transportation compared to hydrogen. This study suggests ammonia fueled solid oxide fuel cell (SOFC) system with electrochemical hydrogen compressor (EHC)-based recirculation. Performance of electrochemical hydrogen pump is based on the experimental data under varying hydrogen and nitrogen concentration. As a result, the suggested system shows 62.04% net electrical efficiency. The efficiency is 10.33% point higher compared to simple standalone SOFC system (51.71%), but 0.02% point lower compared to blower-based recirculation system (62.06%). Further improvement in the EHC-based SOFC recirculation system can be achieved with EHC performance improvement.

Hydrogen Generation by Electrical Discharge through Metal/Water System

  • G. J. Kang;S. Y. Cha;Lee, W. M.;Park, Y. M.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.111-114
    • /
    • 1996
  • Hydrogen generation by dissociation of water is described. The major force for the dissociation comes from the oxidation potential of the reactive metal reacting with water whereas the minor role is played by electrical discharge which helps sustain the reaction. A premixed reactive metal/water system undergoes a fast hydrogen generation upon the ignition by an electrical pulse. In another method the reactive metal can be fed into the discharge. Some characteristics of the methods are discussed.

  • PDF

The Hydrogen Production from the Hydrolysis of Mg-Graphite Pellet for Military Fuel Cells (군용 연료전지 적용을 위한 Mg-Graphite 펠렛의 가수분해 반응을 이용한 수소생산)

  • Park, Minsun;Yu, Minkyu;Kim, Jongsoo;Kwon, Hyuksang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.160-166
    • /
    • 2015
  • On board hydrogen generation from the hydrolysis of an active metal is very attractive due to its economical, convenient, and safe reasons. A Mg-graphite pellet has been designed as a hydrogen source for portable fuel cell. Mg (1 g) + 0.10 g graphite pellet showed an excellent hydrogen generation rate that is equivalent to 15.8 ml/g.min from its hydrolysis. The hydrogen generation rate of the pellet is significantly increased due to the galvanic corrosion by galvanic cells between Mg anode and graphite cathode in a 10.wt. % NaCl solution at a room temperature.