• 제목/요약/키워드: hydro power device

검색결과 22건 처리시간 0.022초

지중 전력 선로 편단접지 시스템에서의 병행지선 및 SVL 설치방안 (Installation Methodology of Parallel Ground Conductor and SVL for Single Point Bonding System on Underground Power Cable)

  • 하체웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.119-121
    • /
    • 2008
  • In underground power cable system, the device for limiting over-voltage is needed when transient over-voltage break out between sheath and ground. For this reason, the SVL(Sheath Voltage Limiter) has been applied on weak points. But the broken SVLs which are installed on the single point bonding system on underground cable are frequently found. In this paper, EMTP(Electromagnetic Transient Program) is utilized to analyze effects on the installation methodology of the parallel ground conductor and SVL for the single point bonding system on the underground cable. The result shows that the proposed installation methodology can be applied for single point bonding system and contribute for power system stabilization.

  • PDF

CFD를 통한 휴대용 수평축 수차의 성능해석 (Performance Analysis of a Portable Horizontal Axis Hydro Turbine by Computational Fluid Dynamics)

  • 박지훈;백상화;최현준
    • 해양환경안전학회지
    • /
    • 제26권5호
    • /
    • pp.561-568
    • /
    • 2020
  • 본 논문에서는 상용코드인 ANSYS CFX를 통한 해양레저 스포츠 및 야외 활동 시 사용 가능한 휴대용 수평축 수차의 유입유속(U) 및 주속비(TSR, Tip Speed Ratio) 변화에 따른 성능해석을 수행하였으며, 해석결과 및 유동장 분석을 통해 설계에 대한 검토 및 장치의 성능을 확인하였다. 또한, 추가적으로 블레이드의 피치각도(αpitch) 변화에 따른 성능해석을 통해 수차의 성능개선에 필요한 데이터를 획득하고자 하였다. 본 논문의 연구 결과 수치해석 케이스 중 주속비 4인 경우, 모든 유입속도 및 블레이드 피치 각도에서 가장 높은 성능을 보였으며, 설계 유속 이하의 일부 조건에서도 설계 출력인 30 W 이상의 출력을 보였다. 그리고 수치해석 케이스 중 가장 높은 출력과 출력계수는 유입유속 1.5 m/s, 블레이드 피치 각도 3°, 주속비 4에서 보였으며, 출력 약 85 W, 출력계수 약 0.30이었다.

전력 계통 축약을 위한 등가 제어기 모델에 관한 연구 (A study on equivalent control device model for power system reduction)

  • 이한민;노규민;장병훈;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.273-275
    • /
    • 1999
  • This paper presents a dynamic equivalencing method in large electric power system for stability analysis. This method of modeling simplified equivalents for parts of the network outside the study area is to evaluate the stability of a study area modeled in detail. Generators are closely coupled in an electrical sense tend to swing together in groups during disturbances, and this behavior can be exploited to reduce the size of the power system model. The characteristics of generators swing together are referred to as coherency Coherency groups whose generators state trajectory are similar to the other generators state trajectory in the same coherency group by a certain disturbance. In this paper, procedures for forming dynamic equivalents of control devices of coherency-based generating units are proposed and the aggregation of the control devices such as excitation system and governor-turbine system is accomplished by this method. This method can deal with the aggregation of the same type of control devices and combination of hydro and steam unit or the many types of excitation systems. etc. This method is shown to be efficient in reducing the number of control device of generating units with small error in the study group by result of case study presented latter part of this paper.

  • PDF

수력발전소 IED의 디지털 보호 알고리즘에 관한 연구 (A Study on Digital Protection Algorithm of IED for Hydroelectric Generating Unit)

  • 박철원
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.149-156
    • /
    • 2014
  • Generator of hydroelectric generating unit is to be protected by the digital protection IED. Now, any IED of large capacity for hydro power plant was not developed by domestic technology. This is because it is required for the generator of the high reliability technology and considered as due to the sale of the market of IED device is small. However, the protection IED must be develop by domestic technology to meet the advanced needs of the construction and replacement of electrical equipment in accordance with the new power plant development. In this paper, a digital algorithms for protection IED of large size of hydroelectric generating unit were designed. The algorithms consist of the stator protection, anti-motoring, overexcitation and loss of excitation. The performance of the algorithms were evaluated by using the simulation data collected from the PSCAD/EMTDC software. From test results, it can be seen that the developed algorithms were not maloperation.

PHASE-B PRE-SIMULATION USING BORON AND GADOLINIUM AS POISON IN THE MODERATOR SYSTEM FOR WOLSONG-1

  • Kim, Sung-Min;Kim, Hyeong-Taek;Donnelly, Jim;Marleau, Guy
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.551-560
    • /
    • 2012
  • The Wolsong-1 (W-1) Phase-B pre-simulations were carried out in preparation for tests to be conducted for the restart of the reactor after a major refurbishment project that included replacement of the pressure tube. These pre-simulations for Wolsong-1 Phase-B differ from those in the past that were performed for the Wolsong-1,2,3,4 tests in that these tests use the WIMS/DRAGON/RFSP-IST code suite for verification of the tests and gadolinium instead of the traditional PPV/MULTICELL/RFSP code system and boron as poison in the moderator system. The use of gadolinium is deemed not to have domestically accumulated experience gained from the previous Phase-B tests. Thus, it is appropriate to conduct a study in order to gain a correct understanding and interpretation of potential differences in test results stemming from using gadolinium rather than boron. Although the calibration of the reactivity device will not be noticeably different using boron and gadolinium at a constant moderator temperature, the temperature dependency of the neutronic behavior due to the presence of gadolinium in the moderator system might be pronounced. The results of the pre-simulations using gadolinium revealed that the moderator temperature reactivity coefficients indeed showed significant differences in comparison with those with boron. In order to secure the validity of the analysis results, the newly acquired WIMS/DRAGON/RFSP-IST code suite was verified against the W-2,3,4 Phase-B test results. The results of the new code suite verifications revealed some overall improvements in accuracy; justification of the use of the code can be claimed for the validation of the W-1 Phase-B test results.

자동동기검출회로 성능진단에 관한 연구 (A Study of In-Depth Diagnosis Method for Automatic Synchronizing Circuits)

  • 박호철;천영식;장기준;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.582-584
    • /
    • 1999
  • Generator has synchronized with power Network after build-up output voltage. In order to prevent a current surge when synchronizing, the conditions such as identical no-load voltages identical no-load frequencies and identical phase positions must be met between generator voltage and network voltage. Hydro-Pump generators or Gas-turbine generators, Co-generation Generators that serve peak load of network are synchronized many times. So, Automatic Synchronizing Circuits are very important service. This report apply Diagnosis methods the Automatic Synchronizing Circuits(Device) by developing simulator.

  • PDF

원자력발전소의 안전등급 FPGA 확인 및 검증 방법 (Verification and Verification Method of Safety Class FPGA in Nuclear Power Plant)

  • 이동일
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.464-466
    • /
    • 2019
  • 원자력 발전소에 사용되는 제어기는 높은 신뢰도를 요구한다. 한국형 디지털 원자력 발전소인 APR1400 (Advanced Power Reactor 1400)을 비롯하여, 과거 많은 원자력 발전소에 FPGA (Field Programmable Gate Array)와 CPLD (Complex Programmable Logic Device, 이하 FPGA로 통칭)가 포함된 제어기가 적용되고 있다. 적용 초기에는 FPGA를 일반적인 IC (Integrated Circuit)처럼 기기검증 및 성능시험으로만 검증을 하였다. 이후 90년대에 들어 FPGA검증에 대한 연구가 시작되면서, FPGA가 칩이 되기 전까지를 소프트웨어로 간주하여 IEEE 1012-2004를 적용하여 소프트웨어 확인 및 검증을 하였다. 현재에는 유럽표준인 IEC 62566을 적용하여 많은 검증을 하고 있다. 이 방법은 현재까지 가장 현명한 방법으로 평가 받고 있다. 이유는 기존의 검증 방법에서 문제가 되었던 SoC (System on Chip)의 특징을 검증하는 방법을 충분히 적용하였기 때문이다. 하지만, IEC 62566은 유럽 표준으로 아직 미국에서는 채택을 하지 않고 있으며, FPGA에 대해서는 IEEE 1012를 적용하는 것을 유지하고 있다. IEEE 1012-2004나 IEC 62566은 기술 표준으로 실무에서는 다양한 방법을 적용하여 기술 표준을 충족시켜서 적용하고 있다. 이 논문에서는 SoC의 검증 방법이 적용된 원자력 안전등급 FPGA에 대한 검증 방법의 절차 및 중요사항에 대해 설명하고자 한다.

  • PDF

3D Numerical Investigation on Reservoir System for an Overtopping Wave Energy Convertor

  • Jin, Jiyuan;Liu, Zhen;Hong, Key-Yong;Hyun, Beom-Soo
    • 한국항해항만학회지
    • /
    • 제36권2호
    • /
    • pp.97-103
    • /
    • 2012
  • Overtopping Wave Energy Convertor (OWEC) is an offshore wave energy convertor, which comprises the circular ramp and reservoir. It collects the overtopped waves and converting water pressure head into electric power through the hydro-turbines installed in the vertical duct, which is fixed in the sea bed. The performance of OWEC can be represented by the operating water heads of the device, which depends on the amount of the wave water overtopping into the reservoir. In the present paper, the reservoir with the duct connecting to the sea water are studied in the 3D numerical wave tank, which has been developed based on the computational fluid dynamics software Fluent 6.3. Both the overtopping motion and the discharges of the reservoir are investigated together, and several shape parameters and incident wave conditions are varied to demonstrate their effects on the performance of OWEC.

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

리튬이온 배터리의 분리막 손상 요인별 방전펄스의 검출과 분석 (Detection and Analysis of Discharge Pulses by Failure Mechanisms of the Separator inside Lithium-Ion Batteries)

  • 임승현;이경렬;김남훈;김동언;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.327-332
    • /
    • 2021
  • Lithium-ion batteries (LIBs) have become a main energy storage device in various applications, such as portable appliances, renewable energy facilities, and electric vehicles. However, the poor thermal stability of LIBs may cause explosion or fire. The thermal runaway is the result of a failure of the separator inside LIB. Damages like tearing, piercing, and collapsing of the separator were simulated in a mechanical, an electrical, and a thermal way, and small discharge pulses of a few mV were detected at the time of separator damages. From the experimental results, this paper provided a method that can identify the separator failure before thermal runaway in the aspect of a potential explosion and fire prevention measures.