• Title/Summary/Keyword: hydride generation

Search Result 62, Processing Time 0.036 seconds

Arsenic Speciation Aanalysis in Bamboo Salts by Hydride Generation-ICP-AES (수소화물 발생-유도결합 플라즈마 원자 방출 분광법을 이용한 죽염중의 비소 종분리 분석)

  • Yu, Byung-Kyu;Lyu, Mu-Sang;Sun, Yle-Shik;Cho, Ki-Sung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.5
    • /
    • pp.674-680
    • /
    • 2012
  • As(III) and As(V) were analyzed in bamboo salts by hydride generation ICP-AES. In order to quantify the total amount of As in bamboo salts, $AsH_3$ was producted by reacting with 6 mol/L hydrochloric acid and $NaBH_4$, which was then analyzed by hydride generation ICP-AES. As(V) was quantified simultaneously after selectively quantifying As(III). As(III) was quantified by determining the total amount of As and then correcting for the amount of As(III). To improve the reliability of the analysis we repeated the experiment several times to check the detection limit, quantification limit, and measurements of our testing methods. According to the result of our quantification analysis of As existing in bamboo salt, the range of total As content was 0.05 mg/kg~0.2 mg/kg and As(V) was over 90% of the total As.

Separation and Sensitive Determination of Sb Species using Yeast Bonded Bio-column with Continuous Hydride Generation (이이스트 고정 bio칼럼을 이용한 Sb의 화학종분리 및 연속적 수소화물발생법에 의한 감도개선)

  • Lee, Jeong-Ok;Kwon, Hyo-Shik;Pak, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.6
    • /
    • pp.696-700
    • /
    • 2010
  • Yeast is immobilized upon $100{\mu}m$ CPG(controlled pore glass bead) to separate $Sb^{3+}$ and $Sb^{5+}$. Continuous hydride generation is performed after the bio-column. The optimum conditions are 0.8 M nitric acid as an eluent with the flow rate of 1.0 mL $min^{-1}$ and the optimum conditions for the generation of hydride are 2 M HCl, 3% (w/v) $NaBH_4$ with the flow rate of 0.83 mL $min^{-1}$, Ar carrier gas flow rate of 50 mL $min^{-1}$. Two species are separated at 112 and 354 seconds each. The sensitivity is enhanced by 10 times for $200{\mu}L$ of sample and the detection limits are 3.0 ppb and 7.0 ppb for $Sb^{3+}$ and $Sb^{5+}$, respectively. When compared with the standard samples, this method showed accurate results.

Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry (Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석)

  • Cheon, Mi-Hee;Kim, Chul;Lee, Hyun-Joo;Kang, Lim-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.399-406
    • /
    • 2003
  • This study was conducted to find out the analysis condition of selenium(Se) in oil refinery wastewater with a high concentration of Se using the atomic absorption spectrometry with hydride generation system (HG-AAS). From various experiments that reduced Se(VI) to Se(IV), the optimum pretreatment condition was determined to be a sample volume of 10 mL, HCl 10 mL, with a 30 min heating time in a water bath. In oil refinery wastewater, as the concentration of organics and constitution became higher, the recovery rates of Se decreased. Therefore, three acid digestion methods ($HNO_3/HClO_4$ digestion, $KMnO_4$ digestion, and microwave acid digestion) were tested on the recovery rates of Se in reference to the digestion of organics, petroleum and oxidation from organic Se(org.), Se(IV) to Se(VI). The experiment results showed that the average recovery rate of Se was the highest in microwave acid digestion, although all of the digestions were more than 90%. In consequence, the pretreatment procedure of microwave digestion followed by HCl addition was the most suitable for selenium analysis in oil refinery wastewater by using HG-AAS.

Determination of Selenium in Milk by ICP-OES (ICP-OES를 이용한 우유의 Selenium 분석)

  • 김효중;박종길;신정걸;백영진
    • Food Science of Animal Resources
    • /
    • v.23 no.4
    • /
    • pp.356-360
    • /
    • 2003
  • The purpose of this paper was to determine the quantity of selenium in milk by inductively coupled plasma optical emission spectrometry. The sample was digested in teflon vessel containing nitric-hydrogen peroxide acid mixture. After digestion, the sample is treated with additional hydrochloric acid. Total selenium was reduced with sodium borohydride and concentrated hydrochloric acid in a simplified hydride generation(HG) manifold. The optimum conditions of HG are 2 M for HCl, 1.5% for NaBH$_4$, 1.2 mL/mim for sample flow. Recovery rates by the standard addition method were 88.0% at 10 ppb and 92.2% at 10 ppm. The relative standard deviations were 4.8 and 3.2%, respectively. This method showed a good accuracy and precision. And so it was highly suitable for determination of small quantity of selenium in milk.

Feasibility of Energy Generation from Chemical Reaction between Hydrogen Peroxide/Hydride (고농도 과산화수소와 수소화물의 지속적인 반응에 대한 연구)

  • SEO, SEONGHYEON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.3
    • /
    • pp.271-277
    • /
    • 2015
  • The present paper discusses about noble idea on various reactions including hydrides, hydrogen peroxide and nano-sized metal powders, which do not emit toxic materials as well as carbon dioxide. Here in this paper, the very first-ever concept that heat energy can be generated from the direct reaction between sodium borohydride and hydrogen peroxide is presented. Sodium hydride as fuel can supply hydrogen reacting with oxygen provided by the decomposition of hydrogen peroxide solution. Solid sodium borohydride can be resolved in water and treated as liquid solution for the easy handling and the practical usage although its solid powder can be directly mixed with hydrogen peroxide for the higher reactivity. The thermodynamic analysis was conducted to estimate adiabatic reaction temperatures from these materials. The preliminary experiment on the reactions conducted using sodium borohydride powder and hydrogen peroxide water solution revealed that the self-propagating reaction can occur and that its reactivity increases with an increase of hydrogen peroxide concentration.

Determination of Selenium in Foods by HG-AAS (HG-AAS에 의한 식품 중의 셀렌의 정량에 대한 연구)

  • Ki-Won Cha;Sang-Ho Park;Jae-Sung Choi
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.12
    • /
    • pp.891-897
    • /
    • 1994
  • A method has been investigated for the determination of Selenium in Ginseng radix, Ganoderma Lucidum and Garlic using hydride generation atomic absorption spectrometry (HG-AAS). The effects of several acids and sodium tetrahydroborate concentration and their flow rate on the determination of Selenium for the hydride generation were investigated. The method of sample decomposition was also investigated using various mineral acids, such as nitric, perchloric and sulfuric acid in the closed system and foreign ion effects were studied. In the optimum conditions, we obtained calibration curve in the range 0-40 ppb. The analytical data of Garlic, Ganoderma Lucidum and Ginseng radix are 289, 296, 198 ppb, respectively.

  • PDF

Ultra-trace Arsenic Determination in Urine and Whole Blood Samples by Flow Injection-Hydride Generation Atomic Absorption Spectrometry after Preconcentration and Speciation Based on Dispersive Liquid-Liquid Microextraction

  • Shirkhanloo, Hamid;Rouhollahi, Ahmad;Mousavi, Hassan Zavvar
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3923-3927
    • /
    • 2011
  • A noble method for pre-concentration and speciation of ultra trace As (III) and As (V) in urine and whole blood samples based on dispersive liquid-liquid microextraction (DLLME) has been developed. In this method, As (III) was complexed with ammonium pyrrolidine dithiocarbamate at pH = 4 and Then, As (III) was extracted into the ionic liquid (IL). Finally, As (III) was back-extracted from the IL with hydrochloric acid (HCl) and its concentration was determined by flow injection coupled with hydride generation atomic absorption spectrometry (FI-HGAAS). Total amount of arsenic was determined by reducing As (V) to As (III) with potassium iodide (KI) and ascorbic acid in HCl solution and then, As (V) was calculated by the subtracting the total arsenic and As (III) content. Under the optimum conditions, for 5-15 mL of blood and urine samples, the detection limit ($3{\sigma}$) and linear range were achieved 5 ng $L^{-1}$ and 0.02-10 ${\mu}g\;L^{-1}$, respectively. The method was applied successfully to the speciation and determination of As (III) and As (V) in biological samples of multiple sclerosis patients with suitable precision results (RSD < 5%). Validation of the methodology was performed by the standard reference material (CRM).

Preliminary Study on Reaction Mechanism for Energy Generation using Hydride and Hydrogen Peroxide (수소화물과 과산화수소를 적용한 에너지 생성 메커니즘 연구)

  • Seo, Seong-Hyeon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.300-303
    • /
    • 2012
  • Global warming has been a serious problem due to excessive emissions of carbon dioxide from the increase of energy consumption. The present study investigates an energy generation mechanism that does not produce carbon dioxide and oxides of nitrogen. A reaction mechanism including sodium borohydride and hydrogen peroxide has been introduced and as a result, thermal energy can be generated from combustion of hydrogen with oxygen. Sodium borohydride dissolved in water reacting with liquid hydrogen peroxide may reveal maximum adiabatic reaction temperature of 1795 K at a mixture ratio of 0.89.

  • PDF

Probabilistic Integrity Assessment of CANDU Pressure Tube for the Consideration of Flaw Generation Time (결함발생 시점을 고려한 CANDU 압력관 결함의 확률론적 건전성평가)

  • Kwak, Sang-Log;Lee, Joon-Seong;Kim, Young-Jin;Park, Youn-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.155-160
    • /
    • 2001
  • This paper describes a probabilistic fracture mechanics (PFM) analysis based on Monte Carlo (MC) simulation. In the analysis of CANDU pressure tube, it is necessary to perform the PFM analyses based on statistical consideration of flaw generation time. A depth and an aspect ratio of initial semi-elliptical surface crack, a fracture toughness value, delayed hydride cracking (DHC) velocity, and flaw generation time are assumed to be probabilistic variables. In all the analyses, degradation of fracture toughness due to neutron irradiation is considered. Also, the failure criteria considered are plastic collapse, unstable fracture and crack penetration. For the crack growth by DHC, the failure probability was evaluated in due consideration of flaw generation time.

  • PDF

Semi-Automatic Hydride Generation and Atomic Absorption Determination of Bismuth with in situ Concentration in a Graphite Furnace

  • Yong-Keun Lee;Dong Soo Lee;Byung Mok Yoon;Hoon Hwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.290-295
    • /
    • 1991
  • A semi-automatic method for the determination of dissolved bismuth at parts per trillion levels is described. The method involves bismuthine generation, in situ collection of bismuthine in a graphite furnace, and atomic absorption detection. In order to facilitate semi-automation of bismuthine generation and separation from aqueous solution, Gore-tex microporous PTEE membrane is used. The absolute detection limit, taken as three times the standard deviation of the instrument noise is 2 pg. The precisions are 3.1% for 100 pg and 1.9% for 1 ng of bismuth, respectively. As many as 90 measurements can be made in an hour.