• Title/Summary/Keyword: hydraulic oil

Search Result 399, Processing Time 0.026 seconds

Stick-Slip Pressure Variations in a Cylinder of Telescopic Boom (Telescopic Boom의 Stick-Slip에 의한 Cylinder의 압력변화)

  • Kim, Shin;Lee, Hyung-Jik;Jung, Jae-Youn
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • In many dynamic systems, there are unwanted oscillation which may arise the reduction of performance. Especially in low sliding speed condition, the stick-slip is an important issue because it because unstable motion as well as inaccurate position control in the system. Most previous works on the stick-slip are, however, only concerned with simple modeling under the condition of constant normal force. The normal force and the amount of hydraulic oil are variable with a cylinder stroke in the telescopic boom. This paper presents the pressure variations during stick-slip with the cylinder of telescope boom. Pressure variations by stick-slip has a similar pattern to that of single mass-spring model. The stick-slip is gradually decreased by means of increased flow rate.

A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(1) (피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동 ${\cdot}$ 소음에 미치는 영향에 관한 연구(1))

  • Park, Sung-Hwan;Lee, Jin-Kul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.74-82
    • /
    • 1999
  • To meet the needs of the hydraulic excavator of large capacity, tandem axial type piston pump which is high pressure and high speed have been developed. But inevitably we can not help facing the problem of noise at that time. In order to reduce the noise of this pump, many researchers have been studying the problem of oil distribution manner. But they are not interested in the symmetric structure of tandem type pump. So, focusing on the symmetric structure of tandem type pump, this paper analyzed unbalanced force developed in the pump chamber and verified the effect of the pumping phase of the piston on vibration and noise of the tandem axial type piston pump theoretically.

  • PDF

A study on the force control of a servo actuator with built-in MR Valve (MR 밸브 내장형 서보 액추에이터의 힘 제어에 관한 연구)

  • Ahn K.K.;Song J.Y.;Kim J.S.;Ahn Y.K.;Park J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • A servo actuator with a valve using MR (Magneto-Rheological) fluid is proposed for fluid control systems. The MR fluid is well known as a functional fluid whose apparent viscosity is controlled by the applied magnetic field strength. The pressure in the MR cylinder can be controlled by the applied magnetic field strength. Good points of the MR cylinder are more simple, compact and reliable structure than a conventional oil hydraulic cylinder. The experimental results show that the MR cylinder could be used as a servo actuator.

  • PDF

New Multi-Function Sizing Centre (MFC)

  • Rundel, Albert;Rauch, Peter
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.745-746
    • /
    • 2006
  • This lecture introduces new press, adapter and control concepts to size multi-level sintered components. The essential thing here is that the advantages of the multi-plate technology have been applied to the sizing adapter concept. Thus, the new concept meets the demands for a modern P/M manufacture and offers sufficient potential to size any future, complex sintered components such as synchronizer hubs, oil pump wheels and VCT parts with highest precision. Furthermore, it outlines a new flexible concept for the parts transfer, including feeding, orientation and lubrication while responding to the high demands on process stability and short change-over times.

  • PDF

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

Performance Analysis and Optimum Design Method of Positive Displacement Turbine for Small Hydropower (소수력발전용 용적형수차의 성능해석과 최적설계법에 관한 연구)

  • Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.514-521
    • /
    • 2007
  • There has been considerable interest recently in the topic of renewable energy. This is primarily due to concerns about environmental impacts. Moreover, fluctuating and rising oil prices, increases in demand, supply uncertainties and other factors have led to increased calls for alternative energy sources. Small hydropower, especially using water supply system, attracts high attentions because of relatively lower cost and smaller space requirements to construct the plant. Moreover. newly developed positive displacement turbine has high acceptability for the system. Therefore, the purpose of this study is focused on the examination of the performance characteristics and proposition of a optimum design method of the turbine for the improvement of the performance. The results show that newly proposed optimum design method for the turbine has high accuracy of performance prediction and good applicability for the performance improvement of the turbine.

A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System (커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구)

  • Lee, Choon-Tae
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

엔진 오일의 공기 혼입과 윤활 특성

  • 최재권
    • Tribology and Lubricants
    • /
    • v.11 no.4
    • /
    • pp.1-12
    • /
    • 1995
  • 여러 가지 필수적인 윤활유 성상과 함께 요즘 개발된 엔진에서 요구되는 중요한 특성 중 하나가 윤활유 내의 공기 혼입(aeration) 문제이다. 만일 윤활유 내에 공기가 일정 한도 이상 혼입되면 윤활유가 수행하는 일반 기능 중 하중을 분산시키는 압력 분산 작용과 윤활 작용 및 마찰열을 식혀 주는 냉각 작용이 제대로 되지 않아 엔진 수명과 내구성에 심각한 문제를 초래한다. 특히 현재 밸브 소음 저감 및 정비성 향상을 위해 대부분의 엔진에서 채용하고 있는 hydraulic valve lash adjuster(HLA)에 미치는 영향이 가장 심각하다. HLA는 그 작동 특성이 엔진 오일의 비 압축성을 이용하고 있기 때문에 만일 HLA 내부의 고압실에 공기가 오일에 섞여 들어간다변 밸브 시스템 강성이 떨어지게 되어 오히려 HLA 사용 목적에 반해 밸크 이상 거동에 의한 소음이 유발될 뿐만 아니라 심하면 밸브가 파단되는 심각한 현상이 초래되기도 한다. 상기한 바와 같이 aeration 현상은 경우에 따라 매우 심각한 문제를 유발하기도 하며 엔진이 고속 고출력화 하면서 그 특성은 더욱 관심사가 되어 왔다. 따라서 엔진 각 부분의 올바른 기능과 신뢰성 확보를 위해 aeration의 특징 발생 원인 및 대책을 살펴보고 특히 oil aeration이 HLA와 엔진 베어링에 미치는 영향에 대해 분석 고찰해 봄으로써 그 특성을 이해하고자 한다.

Life Prediction for High Pressure Hose of Power Steering System by Impulse Pressure Test (충격 압력을 받는 파워스티어링 시스템의 고압호스 수명 예측)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Park, Jong-Won;Lee, Jong-Hwang;Jeong, Won-Wook;Im, Young-Han;Hwang, Kwon-Tae;Lee, Young-Shin;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • The hydraulic hose can be divided with the low pressure, the medium pressure, and the high pressure hose according to the applied pressure. The power steering system in a passenger car can be divided with the high pressure and the low pressure hose. This study deals with the life prediction for high pressure hose to be given impulse pressure which was generated in turning the car. To adjust with external and internal condition, impulse pressure and oil temperature need to be controlled with impulse test system. The result, which is only controlled with the pressure and oil temperature, adapted Calibrated Accelerated Life Test(CALT) method to predict the life of the high pressure hose and analyzed the swagging part by finite element method during the impulse test.

The Lateral Current Force Coefficient in the Real Ship Towing Test (실선 예인실험을 통한 여객선형의 유압횡력계수 고찰)

  • Jung, Chang-Hyun;Nam, Taek-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.373-379
    • /
    • 2016
  • Hydraulic forces on a vessel are changed according to the depth/draft ratio (h/d) during berthing or towing in a lateral direction. It is well known that lateral current force coefficient is dependent on the kinds of vessel in question. However, not much research exists about the characteristics of general ships, except for oil tankers, as suggested by the Oil Companies International Marine Forum (OCIMF). In this paper, lateral current coefficient related to h/d is analyzed in comparison with theoretical values and experiments with a 93m passenger ship. The estimated total resistance on the ship was 14.0 tons under an h/d of 1.6 with a lateral current force coefficient of 1.9. This was found to be similar to the measured value of 13.8 tons on the towing line in actual experiments. Resistances on the ship under an h/d of 3.0 was calculated to be 19.9 tons with a lateral current force coefficient of 1.3. Therefore, the lateral current force coefficient was expected to be 1.3 under an h/d of 3.0, in experiments measured value 20.0 tons. And the discharging currents did not affect the towing force if the towing line was over 30 m, since the towing resistance showed a similar tendency for changes in line length from 30 m to 60 m.