• 제목/요약/키워드: hydraulic model test

검색결과 546건 처리시간 0.028초

Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사 (Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D)

  • 김선주;박기춘
    • 한국농공학회논문집
    • /
    • 제49권5호
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

성덕댐 여수로 수리모형실험 연구 (Hydraulic Model Test for Seongduk Dam Spillway)

  • 장석환;최병규;구본웅;김성택
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1313-1317
    • /
    • 2006
  • In this study, various hydraulic phenomena were analyzed from the dam model experiments and the analyzed results were compared with existing computation results. Sungduk dam model structures were constructed using Froude similarity law by 1:50 scale. From the measurements of hydraulic phenomena at spillway channel, an improvement method was trying to be suggested over shortcoming of existing design plan. The result of model experiment showed no big difference with that of each part's numerical interpretation. Sidewall overflows were observed, as water conveyance occurred due to the linear characteristics of spillways, which raised the necessity for improving the linear forms of spillways. Also, it was judged to be necessary improving load pressure and establishing protective structures at the riverbed grounds of downstream channels.

  • PDF

특정 사축식 피스톤 유압서보모터의 개발 및 성능분석 (A Developmental Study of Bent Axis Piston Type Hydraulic Servo Motor for Military Applications)

  • 이대옥;김학성;안태영;김고도;김기수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.279-287
    • /
    • 1994
  • This paper is prepared as a developmental study of tited axis pistion type hydraulic motor for military applications. The high power precision hydraulic motor requires more advanced techniques to design, analyze, manufacture, test and evaluate. We are trying to build a HW/SW technology base about hydraulic motor by accomplishing this study completsly. We manufactured four perproduction model and performed the test and evaluation with the developmental specifications and test equipments. These results will be used in performance analysis and estimation, and the advanced model development for the military and commercial hydraulic motors.

  • PDF

수리모형실험과 FLOW-3D를 이용한 배수갑문 통수능력 검토 (Estimation of Gate Discharge Capacity by Physical Model Test and FLOW-3D)

  • 박병준;이상화
    • 한국해안·해양공학회논문집
    • /
    • 제20권2호
    • /
    • pp.168-175
    • /
    • 2008
  • 군장 국가산업단지(장항지구) 조성공사 후 단지를 가로지르는 솔리천 하구에 새로 건설될 배수갑문 설계안에 대해 축척모형을 제작하고 현장과 동일한 수리조건을 적용한 수리모형실험을 수행하여 통수능력을 검토함과 동시에 결과의 신뢰도 확보를 위해 상용 3차원 전산유체역학 코드인 FLOW-3D를 이용하여 수치모의를 실시하였다. 수리모형실험과 수치모의에서는 얻어진 통수능은 유사한 결과를 보여주었다.

유압펌프 및 모터 피스톤 조립체의 수명예측을 위한 가속실험 모델 (Accelerated Life Test Model for Life Prediction of Piston Assemblies in Hydraulic Pump and Motor)

  • 이용범;김형의;유영철;박종호
    • 유공압시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.14-22
    • /
    • 2005
  • The safety factor of hydraulic piston pumps & motors due to high pressurization, high speedization and low weight/volume realization to enhance the output density shows a tendency to decrease. Therefore more effective test methods are necessary to predict the exact life. The failure of hydraulic pumps & motors operating in high pressure and high speed mainly occurs in piston-shoe assemblies, and the major failure mode is wearout of the shoe surface. The sensitive parameters in the endurance life test are speed, pressure and temperature, and the failure production increases in proportion to the operating time. In this research, the authors propose the combined accelerated life test model using the analysis method of the combined accelerated life test results of piston-shoe assemblies by applying simultaneously high speed, high pressure and high temperature in accordance with variation of speed, pressure and temperature to reduce the life test time.

  • PDF

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

모형시험에 의한 준설점토지반의 표층안정기법 연구 (A Study on the Shallow Improvement Method for Dredged Clay Fills by the Model Tests)

  • 김석열;노종구;이영철;권수영;김승욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.569-576
    • /
    • 2002
  • Recently, the hydraulic fill method is commonly used in many reclamation projects due to lack of fill materials. The method of hydraulic fill in reclamation is executed by transporting the mixture of water-soil particles into a reclaimed land through dredging pipes, then the dredged soil particles settle down in the water or flow over an out flow weir with the water. In the present study, to compare the soil and sand-mat mixed method with sand-air jet method for shallow improvement of hydraulic fills at southern seashore, the model tests were performed. Through the model test results, the behavior of surface as disturbance of desiccation crust is analyzed.

  • PDF

경사식방파제의 피복재 안정성에 대한 비교 실험 (Hydraulic Model Test for Armor Stability of Rubble-Mound Breakwaters)

  • 이종인
    • 한국해안해양공학회지
    • /
    • 제15권4호
    • /
    • pp.249-258
    • /
    • 2003
  • 본 연구에서는 사석, cube및 tetrapod를 대상으로 불규칙파를 적용하여 경사식방파제의 피복재 안정성에 대한 2차원 실험을 수행하였다. 파복재 중량산정식으로는 Hudson식과 van der Meer식을 대상으로 하였으며, Hudson식은 규칙파, van der Meer식은 불규칙파를 적용한 실험으로부터 얻어진 식이다. 본 연구의 목적은 실험결과를 이용하여 Hudson식과 van der Meer식을 비교 검토하는 것이다

ESTIMATION TECHNIQUE Of AIR CONTENT IN TUTOMATIC TRANSMISSION FLUID BY MEASURING EFFECTIVE BULK MODULUS

  • Cho, Baek-Hyun;Lee, Hyoun-Woo;Oh, Jong-Sun
    • International Journal of Automotive Technology
    • /
    • 제3권2호
    • /
    • pp.57-62
    • /
    • 2002
  • It is well known that the entrained air in oil causes appreciable reduction in the stiffness of hydraulic systems. It makes the response delay of the systems and sometimes destroys the stability. Because the hydraulic systems of automatic transmissions are operated in relatively low pressure and high temperature, it is very important to analyze the effects of the air included in automatic transmission fluid. However, it is difficult to derive the generalized model to describe the effective bulk modulus theoretically or measure it in actual operating conditions of automatic transmissions. This paper reviews previous studies of the air effects in hydraulic systems and the measurement techniques of the effective bulk modulus in operating conditions. Based on this work, the theoretical model with moderate complexity and the measurement technique of the effective bulk modulus considering entrained air effect at real operating conditions are suggested. Our paper also shows that the quantity of the entrained air in the automatic transmission fluid can be estimated from the experimental results.

자연 수리자극을 이용한 소유역 규모 대수층 수리전도도 특성화: 지구통계 진화전략 역산해석 기법의 적용 가능성 시험 (Feasibility Test for Hydraulic Conductivity Characterization of Small Basin-Scale Aquifers Based on Geostatistical Evolution Strategy Using Naturally Imposed Hydraulic Stress)

  • 박은규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권4호
    • /
    • pp.87-97
    • /
    • 2020
  • In this study, the applicability of the geostatistical evolution strategy as an inverse analysis method of estimating hydraulic properties of small-scale basin was tested. The geostatistical evolution strategy is a type of data assimilation method that can effectively estimate aquifer hydraulic conductivity by combining a global optimization model of the evolution strategy and a local optimization model of the ensemble Kalman filtering. In the applicability test, the geometry, hydraulic boundary conditions, and the distribution of groundwater monitoring wells of Hanlim-Eup were employed. On the other hand, a synthetic hydraulic conductivity distribution was generated and used as the reference property for ease of estimation quality assessment. In the estimations, two different cases were tested where, in Case I, both groundwater levels and hydraulic conductivity measurements were assumed to be available, and only the groundwater levels were available, in Case II. In both cases, the reference and estimated hydraulic conductivity fields were found to show reasonable similarity, even though the prior information for estimation was not accurate. The ability to estimate hydraulic conductivity without accurate prior information suggests that this method can be used effectively to estimate mathematical properties in real-world cases, many of which little prior information is available for the aquifer conditions.