• 제목/요약/키워드: hydraulic loading

검색결과 346건 처리시간 0.025초

강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향 (Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall)

  • 어성욱;김건하;손봉호
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.

역 유동층 생물막 반응기에서 수리학적 부하가 생물막 성상에 미치는 영향 (Effect of Hydraulic Loading on Biofilm Characteristics in an Inverse Fluidized Bed Biofilm Reactor)

  • 김동석;최윤찬
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.221-228
    • /
    • 1995
  • Stability of reactor and effect on biofilm characteristics were investigated by varying the hydraulic residence time in an inverse fluidized bed biofilm reactor(IFBBR). The SCOD removal efficiency was maintained above 90 % in the HRT range of 12hr to 2hr, but the TCOD removal efficiency was dropped down to 50% because of biomass detachment from overgrown bioparticles. The reactor was stably operated up to the conditions of HRT of 2hr and F/M ratio of 4.5kgCOD/$m^3$/day, but above the range there was an abrupt increase of filamentous microorganisms. The optimum biofilm thickness and the biofilm dry density in this experiment were shown as $200\mu\textrm{m}$ and $0.08 g/cm^3$, respectively. The substrate removal rate of this system was found as 1st order because the biofilm was maintained slightly thin by the increased hydraulic loading rate.

  • PDF

Packed Column 에어레이터에서 매질로 이용한 발포스티로폼 입자의 산소 전달 효과 (Effects of Oxygen Transfer Rate of a Polystyrene Foam Bead Media in a Packed Column Aerator)

  • 박정환;김유희;조재윤
    • 한국양식학회지
    • /
    • 제13권3호
    • /
    • pp.267-275
    • /
    • 2000
  • 이 연구는 값싸고 높은 비 표면적을 제공할 수 있는 발포스티로폼 입자를 packed column 에어레이터의 산소전달 매질로 이용 가능성을 알기 위하여 매질의 깊이와 수리학적부하량에 따른 산소 전달 특성과 효율을 조사 하였다. 이용된 발포스티로폼 입자는 직경 2.5 mm의 구형이었으며, 비표면적이 1350 $m^2$/$m^3$으로 일반적으로 이용되는 매질에 비해 약 3.7~7.0배 더 넓은 비표면적을 제공할 수 있다. 이 매질을 직경 10 cm, 높이 1 m의 내부 관찰이 용이한 아크릴 관으로 제작한 packed column 에어 레이터에 0, 4.5, 9그리고 18 cm의 매질을 채워 넣고, 수온 20, 25 및 3$0^{\circ}C$에 대해 수리학적 부하량을 2, 4 및 5.6 $m^3$/$m^2$/min로 각각 달리하여 산소전달특성을 실험한 결과(Exp. 1),모든 실험 수온에서 수리학적 부하량이 증가함에 따라 표준산소전달률이 증가하였으나 매질의 깊이는 9 cm 까지는 증가하다가 18 cm에서는 감소하였다. 표준산소전달률은 매질 깊이 9 cm에서 수리학적 부하량이 5.6 $m^3$/$m^2$/min일 때 가장 높았다. 그러나 수리학적 부하량이 증가함에 따라 펌프의 소모 전력이 증가하여, 단위소모 전력당 표준에어레이션 효율은 매질의 깊이 9 cm에서 수리학적부하량 2 $m^3$/$m^2$/min일 때 가장 높았다. 따라서 모든 수리학적 부하량에서 매질의 깊이 9 cm 일 때 표준산소전달률과 표준에어레이션 효율이 가장 좋았다. 이 매질을 직경 20 cm, 높이 2 m의 PVC관으로 제작한 packed column 에어레이터에 깊이를 0, 9, 18, 27 및 36 cm로 넣고 순환여과식 시설 내에 실험실 규모의 적용실험을 통해 에어레이터의 효율을 조사하였는데 (Exp.2), 실험 수온 27$^{\circ}C$에서, Exp. 1에서와 동일한 3개의 수리학적 부하량에서 산소 전달률을 측정한 결과, Exp. 1에서와 같이 수리학적 부하량과 매질의 깊이의 증가에 따라 산소 전달률이 증가하였으며, 매질의 깊이가 가장 깊은 36 cm에 대해, 수리학적 부하량이 2 $m^3$/$m^2$/min 일때, 2 kg 02 kg $O_2$/kW-hr의 가장 높은 표준에어레이션효율을 나타내었다. 위의 두 실험 결과에 따라 packed column 에어레이터에서 발포스티로폼 입자를 산소전달 매질로 이용하여 산소 전달률을 증가시킬 수 있다는 것을 확인할 수 있었다.

  • PDF

압축과 전단 하중을 받는 인공 암석 절리의 수리적 거동에 관한 실험적 연구 (An Experimental Study for the Hydraulic Behavior of Artificial Rock Joint under Compression and Shear Loading)

  • 이희석;박연주;유광호;이희근
    • 터널과지하공간
    • /
    • 제10권1호
    • /
    • pp.45-58
    • /
    • 2000
  • 다양한 하중 조건하의 암석 절리에 대한 수리적 거동을 규명하기 위해서 수리전단 시험이 가능한 주기 전단시험 시스템을 설계, 제작하였다. 실험실에서 인공 절리 시료에 대한 압축,전단 조건하의 수리 시험을 실시하였다. 시험 전의 시료에 대한 3차원 간극 측정을 통해 절리의 간극 분포 특성을 규명하였다. 수직응력에 따른 투수계수 변화는 기존 수리 모델과 잘 일치하였다. 전단 하중하의 수리적 거동은 초기에는 팽창 특성을 따랐으며, 팽창의 증가에 따라 투수계수가 커겼다. 전단이 진행됨에 따라 유동률은 충전물 생성과 간극의 엇갈림으로 인해 다소 일정해졌다. 주기전단 하의 수리 거동 역시 돌출부 손상과 충전물 생성의 영향을 받았다. 또한 압축과 전단 하중하의 수리 간극과 역학 간극의 관계가 조사, 비교되었다.

  • PDF

라이닝-지반 수리상호작용이 해저터널에 미치는 영향 (Effect of hydraulic lining-ground interaction on subsea tunnels)

  • 신종호;박동인;주은정
    • 한국터널지하공간학회 논문집
    • /
    • 제10권1호
    • /
    • pp.49-57
    • /
    • 2008
  • 라이닝 작용수압과 유입량은 지하수 수위 아래 혹은 하 해저터널 설계시 중요하게 고려되어야할 수리요소이다. 이 요소들은 수심, 심도, 수리경계조건의 영향을 받는다. 본 논문에서는 각 설계요소가 라이닝하중과 유입량에 미치는 영향을 수치해석적 도구를 이용하여 살펴보았다. 수심영향해석은 심도 30 m에 건설된 마제형 터널에 대하여 수심과 라이닝/지반 상대투수계수 비를 다양하게 변화시켜 조사하였고, 심도영향 해석은 수심 60 m의 터널에 대하여 심도 및 라이닝/지반 상대투수계수 비를 변화시켜 해석하였다. 해석결과 수리경계조건과 상관없이 수심 및 심도가 증가함에 따라 지반하중이 증가하였다. 이는 배수터널은 침투력의 영향으로, 비배수 터널은 정수압의 영향으로 수두가 증가함에 따라 지반하중이 증가함을 보여준 것이다. 수심, 심도의 증가에 따라 유입량은 선형적으로 증가하였으며, 라이닝/지반 상대투수계수비와 유입량관계는 펼쳐진 S자 곡선(stretched S-curve)형태로 나타남을 확인하였다.

  • PDF

유압식 마찰시험기의 성능 평가에 관한 실험적 비교 연구 (An experimental comparison study on performance evaluation for hydraulic pin-on-disk type tribotester)

  • 서만식;이상욱;구영필;조용주
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.285-291
    • /
    • 1998
  • A hydraulic pin-on-disk type tribotester was developed and it's performance was investigated experimentally. The estimate of the performance was accomplished by comparing those of the pneumatic and the dead-weight loading method. The reliability to the performance was conformed. By hydraulic loading method more accra'ate friction coefficient could be got.

  • PDF

혐기성 생물막법에 의한 유기성 배수의 처리 (Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process)

  • 김용대;정경훈
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

유압식 마찰시험기의 성능 평가에 관한 실험적 비교 연구 (An Experimental Comparison Study on Performance Evaluation for the Hydraulic Pin-on-disk Type Tribotester)

  • 서만식;구영필;조용주
    • 한국정밀공학회지
    • /
    • 제16권5호통권98호
    • /
    • pp.194-199
    • /
    • 1999
  • For the purpose of improving accuracy in friction and wear test, a hydraulic pin-on-disk type tribotester was developed and its performance was evaluated experimentally. The performance estimation of the tribotesrer was accomplished by comparing both the consistency of the applied normal load and the robustness of the control against the mechanical disturbances with those of the pneumatic and the dead weight loading method respectively. The developed hydraulic pin-on-disk type tribotester showed the better reliability in the performance and the hydraulic loading method provided the more accurate friction coefficient.

  • PDF

유압식 어로 윈치 시뮬레이터의 동적 거동 특성 (Dynamic Characteristics of a Hydraulic Fishing Winch Simulator)

  • 이대재
    • 한국수산과학회지
    • /
    • 제37권4호
    • /
    • pp.330-336
    • /
    • 2004
  • To meet the increasing demand from various fishing fields for training of fishing equipment operators, a fishing winch simulator was designed to train maritime students in the correct and safe operation of hydraulic winches under various load conditions related to fishing operations. The aim of this study is to describe the basic dynamic characteristics of the newly developed hydraulic fishing winch simulator and particularly to analyze the mechanical responses produced on the winch operation controls. The winch simulator consists of two winch units, a computer control and data acquisition system, a control consol and other associated mechanisms. When one winch is in hauling mode, the other one will always be in loading mode. The revolution speed of the hauling winch was controlled by a proportional directional control valve, and the braking torque of the loading winch was controlled by a proportional pressure control valve. The simulation experiments indicated that the dynamic characteristics of the hauling winch followed the braking response characteristics of the loading winch. The tests also showed that the warp speed and tension linearly depend on the pressure differential across the motor of the loading winch controlled by operating the proportional pressure control valve during the hauling operation. The experience gained from various training courses showed that the fishing winch simulator was very realistic and it was valuable for training novice winch operators. The results of the winch simulation exercise were recorded and used to evaluate the training on the operation and handling of the winch system. From these test results, we concluded that the tension acting on the warp during hauling operations can successfully be simulated by controlling the pressure differential across the motor with step changes of the control input signal to the proportional pressure control valve of the loading winch.

흡수성 바이오필터 시스템의 오수처리 특성 및 효율 (Sewage Treatment Characteristics and Efficiencies of Absorbent Biofilter Systems)

  • 전기설;권순국;김성배
    • 한국농공학회논문집
    • /
    • 제46권5호
    • /
    • pp.131-139
    • /
    • 2004
  • In this study, on-site sewage treatment tests were conducted using the Absorbent Biofilter System (ABS) under different hydraulic loading rates to examine its treatment characteristics and efficiencies and to determine its feasibility as a small on-site sewage treatment system in a rural area. Results showed that the removal rates of BOD and SS were satisfactory at hydraulic loading rates of 100~150 cm/day, meeting the Korean effluent water quality standards for the riparian zone (10 mg/L). In the case of nutrients (N, P), however, the system did not perform well, necessitating further improvement for nutrient removal. A comparative analysis indicated that as a small on-site sewage treatment system, the ABS would be more suitable than other treatment systems in terms of performance stability, maintenance requirement, and cost-effectiveness and could be applied as an alternative treatment system in Korean rural areas.