• Title/Summary/Keyword: hydraulic connection

Search Result 69, Processing Time 0.026 seconds

Hydrological Studies on the flood and Risk of failure of the Hydraulic Structures(Ⅰ) -On the annual maximum series- (水利構造物의 破壞危險度와 設計洪水量에 관한 水文學的 硏究(Ⅰ) -年最高値 系列을 中心으로-)

  • Lee, Soon-Hyuk;Park, Myeong-Keun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.27 no.2
    • /
    • pp.23-37
    • /
    • 1985
  • This studies were carried out to get characteristics of frequency distribution, probable flood flows according to the return periods, and the correlation between return periods and those length of records affect the Risk of failure in the annual maximum series of the main river systems in Korea. Especially, Risk analysis according to the levels were emphasized in relation to the design frequency factors for the different watersheds. Twelve watersheds along Han, Geum, Nak Dong, Yeong San and Seom Jin river basin were selected as studying basins. The results were analyzed and summarized as follows. 1. Type 1 extremal distribution was newly confirmed as a good fitted distribution at selected watersheds along Geum and Yeong San river basin. Three parameter lognormal Seom Jin river basin. Consequently, characteristics of frequency distribution for the extreme value series could be changed in connection with the watershed location even the same river system judging from the results so far obtained by author. 2. Evaluation of parameters for Type 1 extremal and three parameter lognormal distribution based on the method of moment by using an electronic computer. 3. Formulas for the probable flood flows were derived for the three parameter lognormal and Type 1 extremal distribution. 4. Equations for the risk to failure could be simplified as $\frac{n}{N+n}$ and $\frac{n}{T}$ under the condition of non-parametric method and the longer return period than the life of project, respectively. 5. Formulas for the return periods in relation to frequency factors were derived by the least square method for the three parameter lognormal and Type 1 extremal distribution. 6. The more the length of records, the lesser the risk of failure, and it was appeared that the risk of failure was increasing in propotion to the length of return periods even same length of records. 7. Empirical formulas for design frequency factors were derived from under the condition of the return periods identify with the life of Hydraulic structure in relation to the risk level. 8. Design frequency factor was appeared to be increased in propotion to the return periods while it is in inverse proportion to the levels of the risk of failure. 9. Derivation of design flood including the risk of failure could be accomplished by using of emprical formulas for the design frequency factor for each watershed.

  • PDF

A Study on the Field Application of Automatic Grouting System (자동화 그라우팅 기법의 현장적용성에 관한 연구)

  • Do, Jongnam;Park, Junghwan;Choi, Dongchan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2012
  • In Korea, grouting has been mostly designed and constructed by experiences without expert knowledge and theoretical study. So there are a lot of problems related to the quality and safty of grouting. Therefor, in this paper the quality management skills and method were discussed through out by using the auto-grouting method and field test of grouting for the construction. Through the limit water injection test of the soil, it make the optimum injection pressure and injection speed of grouting, and through the lugeon test of the rock, it make assess the permeability of before and after grouting. In order to prevent the hydraulic fracture of soil and break away from the grouts if it apply four kinds of mode of grouting stop criteria, injection effects can be improved. From the above characteristcs designers evalute the fitness values of injection pressure(p), injection speed(q) and grouting penetration time(t). So far, to record and manage pressure(p) and speed(q) of grouting autographic devices such as intergation flow-meter usually record data in a roll of paper. Intergration flow-meter can record grouting flow quantity exactly, but the recorded pressures differ from the any basis such as intitial, intermediate and final point. Therefore, it has been argued that is a need of reliable method to describe the connection between the pressure recorded by an intergration flow-meter and the special properties of the grouting target ground. auto-grouting method can describe the reliable connection between the grouting pressure and the special properties of the grouting target ground. So, in this paper by using auto-grouting method, it is expected that to secure basis of quality control techniques construction.

Structural and Layout Design Optimization of Ecosystem Control Structures(1) -Characteristics of Mooring Force and Motion Control of the Longline Type Scallop Culturing Facility- (생태계 제어 시설물의 설계 및 배치 최적화(1) -연승식 양식시설의 계류력 특성 및 동요저감에 관한 연구-)

  • RYU Cheong-Ro;KIM Hyeon-Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.35-48
    • /
    • 1995
  • To develop the optimal design method for the longline type scallop culturing facilities in the open sea numerical calculations and hydraulic model experiments are carried out for the stability and function optimization. Using the results for the motion and tension of the facilities, stable design concepts and effects of motion control system by vertical anchor and resistance discs art discussed. The results of this study that can be applied to the design are as follows: 1) Total external forces by design wave $(H_{1/3}\;=\;6,7\;m,\;T_{1/3}\;=\;12sec)$ at the coastal waters of Jumunjin for unit facility (one main line) are estimated to 5-20 tons, and required anchor weights are 10-40 tons in the case of 2-point mooring system. Though the present facilities are stable to steady currents, but is unstable to the extreme wave condition of return period of 10 years. 2) The dimensions and depth of array systems must be designed considering the ecological environments as well as the physical characteristics including the mooring and holding forces that are proportional to the length and relative depth of main line to wave length, and the number of buoys and nets. 3) Oscillation of the facility is influenced by water particle motion and the weight of hanging net, and is excited at both edge, especially at the lee side. To reduce the motion of the nets, the vertical anchoring system and the resistence disc method are recommended by the experimental results, 4) The damage of rope near the anchor by abrasion should be prevented using the ring-type connection parts or anchor chains.

  • PDF

Development study of ground water management system making use of GIS ( Well analysis program, connection program of ground water modeling ) (GIS를 이용한 지하수관리시스템 개발 연구 (관정분석 프로그램, 지하수모델링 연계프로그램))

  • 이병호;김양빈;설민구;송양권;송무영
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.235-248
    • /
    • 2002
  • Ground water development skill growth and life circumstances improvement increase ground water use. So managerial difficulties and various problems about ground water occur. Poor ground water management organization, lack of management person, thoughtless development add ground water pollution and lack of water volume. And local excessive developments or abandoned well occur. This paper presents ground water management system model making use of GIS and helps effective management by realizing necessary analysis functions in ground water management system and ground management methods. Local information of ground water recorded and development data, site examination data made D/B. And linearment analysis data making use of a satellite image data, hydraulic test data, the quality of water examination data, these local characteristic values made out thematic maps and making use of these data can form elementary data of ground water modeling It makes easy to understand environmental development conditions and pollution source conditions about new ground water development location, linearment growth, DRASTIC, the quality of water examination. Ground water management system making use of these functions can choose right location of ground water.

  • PDF

Assessments of Hydraulic Properties of Geotextiles with Fiber Composition Factors (섬유 구성인자에 의한 지오텍스타일의 수리학적 특성 평가)

  • Jeon, Han-Yong;Chung, Jin-Gyo;Chang, Yong-Chai
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • The effects of fiber composition factors of 14 geotextiles which are thickness, porosity, fiber length and diameter etc. on the transmissivity were examined and in-plane permeability of geotextiles under thickness change, transmissivity, confined load were analyzed by the constitutive equations. And the effects of laminar structure on the permittivity of laminar geotextile composites which were manufactured with fiber packing densities were assessed. Transmissivities were increased with thickness of geotextiles and in-plane permeability coefficients were increased with porosity and fiber diameter. The effects of porosity were decreased with normal stress and slightly increased with fiber length. Transmissivities were increased with fiber diameter and showed same tendensy for the same fiber length. Permittivities of laminar geotextile composites were influenced by the waterhead loss in the inner interface and the connection shape of these composites to water path was interpreted as bell mouth type or soft flux pipe type.

  • PDF

Application of Umbilical System for Launch Vehicle (우주 발사체 엄빌리칼 시스템의 현황 및 적용사례)

  • Kim, Dae Rae;Lim, Chankyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.21-25
    • /
    • 2017
  • The umbilical system used for launch vehicle is to connect all ground supply lines (Pneumatic, hydraulic and electrical) to launch vehicle and disconnect those at few second before launch vehicle lift-off (or simultaneously with launch vehicle lift-off). During launch preparation stage, all umbilical shall be securely connected and also at separation stage, separation of all umbilical line shall be guaranteed. Therefore finding an appropriate connection force is a key factor on development of umbilical system. According to these design requirement, various kind of umbilical system has been developed from early stage of space development till today. In this paper, various kind of umbilical system developed so far is introduced according to its feature and operational concept. Also, umbilical system used for KSLV-II is introduced

  • PDF

Text Mining Analysis on the Research Field of the Coastal and Ocean Engineering Based on the SCOPUS Bibliographic Information (해안해양공학 연구 분야의 SCOPUS 서지정보 Text Mining 분석)

  • Lee, Gi Seop;Cho, Hong Yeon;Han, Jae Rim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.1
    • /
    • pp.19-28
    • /
    • 2018
  • Numerous research papers have been accumulated due to the development and computerization of bibliometrics. This made it difficult to review all of the related papers published worldwide to conduct the study. However, due to the development of Natural language processing techniques, the tendency analysis of published research papers has become easier. In this study, text mining analysis using the statistical computing language R was carried out based on the bibliographic information of SCOPUS DB (Data Base) in the field of coastal and ocean engineering. As expected, the term 'wave' predominates, and it was confirmed that numerical analysis and hydraulic experiments were still dominant from the terms 'numerical model', 'numerical simulation', and 'experimental study'. In addition, recent use of the term 'wave energy' related to marine energy has been recognized. On the other hand, it was quantitatively confirmed that the frequency of connection between 'wave', and 'height' or 'energy' prevailed, and suggested the possibility of high resolution analysis by detailed field and period in the future.

Influence Analysis on the Number of Ruptured SG u-tubes During mSGTR in CANDU-6 Plants (중수로 증기발생기 다중 전열관 파단사고시 파단 전열관 수에 대한 영향 분석)

  • Seon Oh Yu;Kyung Won Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • An influence analysis on multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout is performed to compare the plant responses according to the number of ruptured u-tubes under the assumption of a total of 10 ruptured u-tubes. In all calculation cases, the transient behaviour of major thermal-hydraulic parameters, such as the discharge flow rate through the ruptured u-tubes, reactor header pressure, and void fraction in the fuel channels is found to be overall similar to that of the base case having a single SG with 10 u-tubes ruptured. Additionally, as the conditions of low-flow coolant with high void fraction in the broken loop continued, causing the degradation of decay heat removal, the peak cladding temperature (PCT) would be expected to exceed the limit criteria for ensuring nuclear fuel integrity. However, despite the same total number of ruptured u-tubes, because of the different connection configuration between the SG and pressurizer, a difference is foud in time between the pressurizer low-level signal and reactor header low-pressure signal, affecting the time to trip the reactor and to reach the PCT limit. The present study is expected to provide the technical basis for the accident management strategy for mSGTR transient conditions of CANDU-6 plants.

Feasibility of Granular Activated Charcoal as a Detector in Fluorescent Tracer Tests (입상 활성탄을 이용한 형광물질 추적자시험 적용성 연구)

  • Lee, Jin-Yong;Hwang, Hyoun-Tae;Yi, Myeong-Jae;Kim, Yong-Cheol;Yum, Byoung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.86-93
    • /
    • 2007
  • In recent tests using tracer have been frequently conducted by fluorescent tracers. In this study, granular activated charcoal (GAC) as a detector for the fluorescent tracers (rhodamine WT and uranine) was investigated through laboratory and field tests. In the laboratory tests, tracer concentrations of rhodamine WT and uranine determined by the GAC were slightly different from those of standard solutions but they were excellent in linearity. Results show that GAC is excellent as tracer detector when concentration of the fluorescent tracers is greater than 10 & micro; g/L whileas no obvious differences in mixed solutions of the two tracers due to interferences. Compared to conventional methods of water sampling, field results shows a high potential of GAC as a tracer in the field. Our results also show that wet analysis is better for the lower concentrations of tracers whileas dry analysis is good for high concentrations of tracers. This study demonstrates that fluorescent tracer detection using the GAC is very useful and economical for a hydraulic connection between target areas and very longer period of the tracer test.

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF