• 제목/요약/키워드: hydraulic boundary

검색결과 278건 처리시간 0.024초

지하수 유동 모텔을 이용한 지하수위 변동법의 적용성 분석

  • 구민호;이대하
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.28-31
    • /
    • 2002
  • The water level fluctuation (WLF) method is a conventional method for quantifying groundwater recharge by multiplying the specific yield to the water level rise. A 2-D unconfined flow model with a time series of the recharge rate is developed. It is used for elucidating the errors of the WLF method which is implicitly based on the tank model where the horizontal flow in the saturated zone is ignored. Simulations show that the recharge estimated by the WLF method is underestimated for the observation well near the discharge boundary. This is due to the fact that the hydraulic stress resulting from the recharge is rapidly dissipating by the horizontal flow near the discharge boundary Simulations also reveal that the recharge was significantly underestimated with increase in the hydraulic conductivity and the recharge duration, and decrease in the specific yield.

  • PDF

The Lubrication Characteristics of the Vane Tip Under Pressure Boundary Condition of Oil Hydraulic Vane Pump

  • Cho Ihn-Sung;Oh Seok-Hyung;Song Kyu-Keun;Jung Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1716-1721
    • /
    • 2006
  • The Lubrication Mode of line contacts between the vane and the camring in an oil hydraulic vane pump has been investigated. First, the variations of the radial force of a vane were calculated from previous measurements of dynamic internal pressure in four chambers surrounding a vane. Next, the lubrication modes were distinguished with Hooke's chart, which is an improvement over Johnson's chart. Finally, the influence of the boundary conditions in the lubrication region on the fluid film lubrication was examined by calculating the film pressure distributions. The results showed that the lubrication mode of the vane tip exists in the rigid-variable-viscosity region, and that discharge pressure higher than 7 MPa greatly affects the oil film pressure in the small and the large arc section because of the Piezo-viscous effect.

The Lubrication Characteristics of the Vane Tip Under Inlet Pressure Boundary Conditions for an Oil Hydraulic Vane Pump

  • Cho Ihn-Sung;Oh Seok-Hyung;Jung Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2179-2186
    • /
    • 2005
  • The lubrication modes of line contact between the vane and the camring in an oil hydraulic vane pump have been investigated. First, variations of the radial acting force of a vane were calculated from previously measured results of the dynamic internal pressure in four chambers surrounding a vane. Next, distinctions of the lubrication modes were made using Hooke's chart, which represents an improvement over Johnson's chart. Finally, the influence of boundary conditions in the lubrication region on fluid film lubrication was examined by calculating film pressure distributions. The results show that the lubrication modes of the vane tip are a rigid-variable viscosity region. This region discharges pressure higher than 7 MPa, and exerts a great influence on oil film pressure in the large arc section due to the Piezo-viscous effect.

지하수-터널 수리상호작용에 따른 터널의 장기거동 연구 (A study on the long-term behavior due to the hydraulic interaction between ground water and tunnel)

  • 신종호;신용석;안상로;박동인
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.239-248
    • /
    • 2006
  • The interaction between ground water and structure is complicated behavior which cannot be easily investigated In the laboratory and monitored in the fields. In this study numerical simulation of the interactive behavior was performed using sophisticated coupled-finite element method. Hydraulic behavior of structure is modeled using solid elements with finite Permeability. Recovery of ground water table in the long-term is considered by controlling hydraulic boundary conditions. The results showed that the interaction effect is significant. Particularly non-symmetry in the lining permeability resulted in highly unbalanced pore water pressure which may cause detrimental effects on inner linings of tunnels acting as drains.

  • PDF

가변구조이론을 이용한 편로드 유압실린더의 디지탈제어 (A study on digital control of the single-rod hydraulic cylinder using variable)

  • 이교일;김동춘
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1133-1138
    • /
    • 1991
  • A control of nonlinear system is motivated by the fact that all real plants are nonlinear systems and model identification introduces parameter errors. The purpose of this study is to design a Discrete Variable Structure Controller(DVSC) for single-rod hydraulic cylinder system. The model contains uncertain parameters which we known to lie upper and lower bounds. In the design of DVSC, the boundary layer concept was adopted to reduce cattering. The DVSC was evaluated through digital computer simulation and compared with a VSC (analog controller).

  • PDF

CORE THERMAL HYDRAULIC BEHAVIOR DURING THE REFLOOD PHASE OF COLD-LEG LBLOCA EXPERIMENTS USING THE ATLAS TEST FACILITY

  • Cho, Seok;Park, Hyun-Sik;Choi, Ki-Yong;Kang, Kyoung-Ho;Baek, Won-Pil;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1263-1274
    • /
    • 2009
  • Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer.

천층터널 주변의 흐름거동 및 수치 해석적 모델링기법 연구 (A study on the flow behavior around shallow tunnels and its numerical modelling)

  • 신종호;최민구;강소라;남택수
    • 한국터널지하공간학회 논문집
    • /
    • 제10권1호
    • /
    • pp.37-47
    • /
    • 2008
  • 터널 설계 및 시공시 지하수 영향에 대한 정확한 이해가 필요하며, 이를 위해 터널 주변의 흐름거동을 파악하는 것이 중요하다. 본 연구에서는 지하수 아래 건설된 배수형 천층터널에 대한 모형실험을 실시하여 주변 지하수 흐름조건과 지반의 토피고에 따른 터널 주변의 지하수 흐름거동을 조사하였다. 실험결과 정상류/부정류의 지하수 흐름조건은 터널내 유입량이나 도달시간에는 영향을 미칠 수 있으나, 터널 주변 흐름거동에는 큰 영향을 미치지 못함을 확인할 수 있었다. 또, 토피고가 증가할수록 배수공이 위치한 터널 하부로의 유선 집중현상이 뚜렷하게 관찰되었다. 모형실험에 대한 수치해석결과, 배수형 천층터널 주변의 흐름거동을 수치해석으로도 재현 가능함을 확인하였다. 배수형 천층터널의 경우 수리경계조건이 터널주면 유출이 아닌 배수공 유출로 모사하는 것이 보다 타당함을 보였다.

  • PDF

정압주입시험을 이용한 지하수유동차원 해석 (Flow Dimensional Analysis for Constant Pressure Injection Test)

  • 이은용
    • 지질공학
    • /
    • 제3권2호
    • /
    • pp.149-165
    • /
    • 1993
  • 지하매질의 유동특성을 알기 위한 직접적인 방법은 아직도 현장수리시험에 의존하고 있다. 열극암반에서 유동모델의 개념정립을 위하여는 열극체계분포와 특히, 수리시험해석결과가 중요시되고 있다. 국내에서 수행되고 있는 수리시험은 조사공구간별에 따른 수리전도도를 방사상의 정상류로 가정하여 결과를 해석하고 있다. 또한 시험대상 매질을 균질한 대수층 또는 단순한 기하학적 형태의 매질로 간주하며 구간별 투수량계수는 시험구간을 가로지르는 각 열극의 투수량계수의 합과 같다고 가정한다. 국내 기존의 수리시험 및 해석방법으로는 수리학적 경계면의 영향(boundary effects)이나 유동로의 기하학적 형태(flow geometry)에 대한 자료를 얻기가 힘들며, 일정한 조사공 주변을 벗어나면 투수성열극의 연결성에 대한 정보를 구할 수 없다. 열극특성을 고려한 지하수유동 해석을 위하여 단일공 정압주입시험을 실시하였으며, 비정상류해석방법을 통하여 유동차원(flow dimension)에 대한 분석을 시도하였다. 시추시에는 단일패커시험을 일정구간별로 시행하였으며, 조사공의 시추후에는 이중패커에 의한 구간별 시험을 실시하였다. 비정상류해석으로 구한 수리전도도값은 정상류해석의 결과와 큰 차이(10배 이내)는 없었으나, 정압하에서 도출된 유동량변화곡선에서 유동차원분석이 가능하였다. 상부구간(<10m 깊이)의 단일 및 이중패커시험결과는 모두 정상류의 유동차원이 나타났으며, 이는 영향반경의 경계면이 open system임을 알 수 있다. 15m 깊이에서 도출된 유동량변화곡선은 1차원 유동상태에서 3차원(구상유동)으로 변화하였다. 하부구간(25m 깊이)의 시험결과는 closed system 특성이 관찰되었으며, 이는 조사구간에서 연결된 열극이 수리적으로 격리되어 있음을 알 수 있다. 현장수리시험으로부터 보다 많은 자료를 도출하기 위하여는 무엇보다도 수리시험장비의 보완이 필요하다. 특히 조사구간을 완벽하게 분리할 수 있는 패커장비와 미세한 유동량변화를 계측할 수 있는 유량계의 확보가 필수적이며, 조사구간의 압력변화를 자동기록할 수 있는 계측기기가 필요하였다.

  • PDF

대수층 축열 에너지(ATES) 시스템 모델에서 지하수 유동 영향에 의한 지반내 온도 분포 예측 시뮬레이션 (Simulation of thermal distribution with the effect of groundwater flow in an aquifer thermal energy storage (ATES) system model)

  • 심병완
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having the effect of groundwater movement, understanding of thermohydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated by using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.001 are shaped circular, and the center is moved less than 5 m to the direction of groundwater flow in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of east boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

경사식 방파제의 수리특성 결정을 위한 수치해석 (Numerical Analysis on the Determination of Hydraulic Characteristics of Rubble Mound Breakwater)

  • 박현주;전인식;이달수
    • 한국해안해양공학회지
    • /
    • 제14권1호
    • /
    • pp.19-33
    • /
    • 2002
  • 경사식 방파제의 설계에 필요한 정보를 제공할 목적으로 수리특성들의 계산을 비교적 쉽게 수행하기 위한 수치해석기법의 수립을 시도하였다. 수치해석은 방파제 외부의 파동장과 내부 공극매체에서의 파동장을 결합시킴으로써 반사율, 전달율(월파전달율과 투과전달율) 그리고 개체내부의 간극수압을 계산하는 것이다. 외부 파동장은 장파가정의 근사 이론을, 내부 파동장은 경계요소법을 이용하여 해석하였다. 수치해석결과를 수리실험결과와 비교한 결과, 반사율과 전달율은 허용오차 범위내에서 비교적 잘 일치하는 것으로 나타났다. 또한, 간극수압은 정량적으로는 다소의 차이를 보이나 정성적으로는 대체적으로 유사한 성향을 보이는 것으로 나타났다. 정량적 차이를 극복하기 위하여 전사면에서의 비선형 파동장에 의한 동수압을 직접 계측하여 수치해석에 입력하는 방안을 제시하였다