• 제목/요약/키워드: hydraulic actuator control

검색결과 214건 처리시간 0.031초

표준형 발전소용 터빈 밸브 작동기 성능 분석 시스템 개발 (The development of turbine valve actuator efficiency analysis system for the standard power plants)

  • 노재희;김상협;이동일;양천규;신을영;정재원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.537-541
    • /
    • 2002
  • This paper is about the development of the turbine valve actuator efficiency analysis system for the standard power plants. We developed hydraulic power unit and turbine valve actuator controller. We designed control algorithm for turbine valve actuator, implemented and verified it at the industrial plants.

  • PDF

비대칭형 유압 실린더를 사용한 능동현가 시스템에서의 궤한 선형화와 최적제어기법을 이용한 이득계획제어기 설계 (Gain-scheduled controller design of an Active Suspension System with an Asymmetric Hydraulic Cylinder using Feedback linearization technique & optimal)

  • 장유진;김상우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.452-454
    • /
    • 1998
  • Asymmetric cylinders are usually used as an actuator of active suspensions. The conventional optimal controller design does not include actuator dynamics as a state. and force controller is needed to track the desired force. But the actuator is not ideal, so performance of an active suspension system is degraded. In this paper, we take account nonlinear actuator dynamics and obtain a linear model using a feedback linearization technique then apply optimal control method. For real time application, gain-scheduling method is used. Effectiveness of proposed method is demonstrated by numerical simulation of 1/4 car model.

  • PDF

PLC를 이용한 ER밸브-FHA의 제어특성에 관한 연구 (A Study on the Control Characteristics of FHA by Using PLC)

  • 장성철;홍순남
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.331-336
    • /
    • 2013
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. As the strength of the electric field increases, more clusters in flow are made and these clusters are thought to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system. Using the manufactured pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller(PLC).

DOB를 이용한 제철설비용 강인 서보 제어시스템 구현 (Design of the Robust Servo Control System for Steel Making Plant using Disturbance Observer Algorithm)

  • 김동삼;허윤제;정완균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.693-696
    • /
    • 2003
  • Among many servo control systems in steel making plant, AGC system in hot rolling mill is very important to get a accurate strip thickness for good quality. AGC (Auto Gauge Control) system controls the roll gap to maintain the required thickness by using the variation of roll force and the measure of output thickness. In this paper, a simulator of AGC system which unifies both hydraulic servo control system and AGC algorithm is suggested. After proving the concurrence of algorithms between the simulator and real system, main actuator system is added. Instead of usual PI system used in present system, DOB control scheme is applied and shows the effect of disturbance attenuation well.

  • PDF

유체기구를 이용한 유압계통의 충격치제어에 수탄되는 반응지연에 관한 연구 (A Study on the Associated Response Lag in Shock Control of Hydraulic System Using Fluid Device)

  • 이주성;이계복
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1488-1495
    • /
    • 2002
  • The response time represents how fast a system responds to a given disturbance at the system boundary. Flow restricting devices for controlling transients can result in a decrease in the peakm pressure, but may change response time. Response lag in a hydraulic system leads to inefficient working cycle and operator discomfort. The experiments were conducted in order to get information on the parameters which exert appreciable influence on the response time. The experimental apparatu including a hydraulic actuator, orifice and a hydraulic pump was an idealization of a bucket hydraulic shifting system. Experimental results show that the response time depends on operating pressure and flow rate. The effects of orifice type and size on the response time are quantified.

NEW MODELING AND CONTROL OF AN ASYMMETRIC HYDRAULIC ACTIVE SUSPENSION SYSTEM

  • Kim, Wanil;Sangchul Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.490-495
    • /
    • 1998
  • In this paper an asymmetric hydraulic actuator which consists of single acting cylinder and servo valve is modeled for a quarter car active suspension system. This model regards the force as an internal state rather than a control input. The control input of the model is the sum of oil flows that pass through the valve's orifices. The resulting dynamic equation in the state space ap-pears a feedback connection of a nominal linear time in-variant term with a nonlinear bounded uncertain block. Since this model makes it possible to eliminate the force control phase, analysis and controller design are made straightforward and simple. Well known LQR method is then applied. Simulation and test rig experiment show the effectiveness of this approach in modeling and control.

  • PDF

구조물 진동제어를 위한 전자석구동 HMD의 응용에 관한 연구 (A study on the Application of Electromagnetic Type HMD for Vibration Control of Structure)

  • 최현;정정교;김두훈;이상조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.280-285
    • /
    • 2000
  • With recent development of technology of high stiffness material and the structural design, the construction of high rise structures such as tall building, tower has increased. The more flexible and slender structure is vulnerable to the internal and external dynamic loads induced by earthquake, wind and traffic load. There have been great effort and many researches to minimize the influence of dynamic loads on the structure. The traditional and stable method, the application of the passive damper, is not able to comply with various dynamic loads, while the mass damper which active control technology is integrated can effectively comply with load types. Therefore, the application of active control of huge structures with AMD(Active mass damper) or HMD(Hybrid Mass damper) is increasing. Up to now, most of actuators are servomotor and hydraulic actuator. But it is known that the electromagnetic actuator applies non contacting control force, which makes the control system easier with no characteristic change depending on time. In this paper, Hybrid mass damper with electromagnetic actuator was designed and applied to building scaled structure. The performance of designed HMD tested by shake table test is included.

  • PDF

유압구동식 4족보행 로봇의 설계 및 제어 (Design and Control of a Hydraulic Driven Quadruped Walking Robot)

  • 김태주;원대희;권오흥;박상덕;손웅희
    • 로봇학회논문지
    • /
    • 제2권4호
    • /
    • pp.353-360
    • /
    • 2007
  • This paper proposes the trot gait pattern generation and online control methods for a quadruped robot to carry heavy loads and to move fast on uneven terrain. The trot pattern is generated from the frequency modulated pattern generation method based on the frequency modulated oscillator in order for the legged robots to be operated outdoor environment with the static and dynamic mobility. The efficiency and performance of the proposed method are verified through computer simulations and experiments using qRT-1/-2. In the experiments, qRT-2 which has two front legs driven by hydraulic linear actuators and two rear casters is used. The robot can trot at the speed up to 1.3 m/s on even surface, walk up and down the 20 degree inclines, and walk at 0.7 m/s on uneven surface. Also it can carry over 100 kg totally including 40 kg payload.

  • PDF

유연성 포인팅 시스템의 진동모드 보상을 위한 2단계 슬라이딩 모드 제어기 (Two-Stage Sliding Mode Controller for Bending Mode Suppression of a Flexible Pointing System)

  • 박장현;김경완;이교일;김학성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.971-976
    • /
    • 1996
  • A flexible pointing system mounted on top of a vehicle suffers from performance degradation due to bending vibrations as the vehicle runs on a bump course. In order to improve the pointing performance, the pointing structure's vibrations should be suppressed. In this paper, a nonlinear controller is designed to control the tip position of the pointing system while actively suppressing the vibrations. To cope with high order dynamics and nonlinearities of the plant and hydraulic actuating system, a two-stage sliding mode controller is devised. The desired actuating pressure is obtained in the first stage and then the in put current In the hydraulic servo system is computed to generate the pressure. The simulation results show the effectiveness of this scheme and improvements in pointing accuracy.

  • PDF

IMV를 사용한 유압굴삭기 붐 동작의 에너지 절감 (Energy Saving in Boom Motion of Excavators using IMV)

  • 허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권3호
    • /
    • pp.1-7
    • /
    • 2017
  • Energy consumption of conventional hydraulic excavators controlled by MCV is considerable when negative load is applied because the meter orifice and meter-out orifice are machined in one spool. Therefore, IMV is introduced to save energy use of hydraulic excavators, but existing hydraulic excavators have various advantages so it is difficult to make a clear comparison. In this study, we compare the use of an existing MCV excavator that has many advantages such as negative control, and IMV for boom up and down operation, and if IMV is used to save energy, we will examine the cause. If possible, for comparability under the same conditions, both systems use pressure balance valves to minimize power consumption when not using power in the actuator. The orifice area at each notch of each valve is calculated, and energy saving is verified by comparing the two systems through simulation.