• 제목/요약/키워드: humidity control characteristic

검색결과 24건 처리시간 0.022초

무기질 도료의 조습성능에 관한 연구 (A study on humidity control characteristics of inorganic paint)

  • 허정용;최창호;이윤규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1225-1230
    • /
    • 2008
  • Recently the building material have been developed with the concept of controlling the indoor environment as well as the concept of emitting contaminants less. So, a lot of products with humidity control characteristics put it on the market. However, objective evaluation to these products doesn't work out. Thus consumers cannot obtain accurate information to these products. Therefore, we selected inorganic paint in the functionality materials and evaluated its humidity control characteristic in this research. We divided by four stages and evaluated this inorganic paint. The 1st and 2nd third experiments were executed on a natural condition and the fourth experiment was executed with humidity had been raised by using the humidifier.

  • PDF

Pottier소자를 이용한 열전 제습기 설계 및 구현 (Design and implementation of thermoelectric dehumidifier using pottier module)

  • 장재철;양규식
    • 한국정보통신학회논문지
    • /
    • 제3권3호
    • /
    • pp.671-679
    • /
    • 1999
  • 본 논문에서는 습도를 세어하기 위해 습도센서를 사용하여 습도를 측정 제습 입력값과 비례 제어를 위해 범용 $\mu$-processorPIC16C54와 Thermoelectric module을 사용하여 구현하였다. Pottier Module 모델에 따라 크기와 특성이 다양하고 Module의 종류에 따라 그에 따른 적절한 열저항을 유지할 수 있도록 하는 방열판 선택 또한 매우 중요한 설계 요소이다. 열전소자를 사용하여 전자제습기를 구현함으로써 국부공간의 무소음, 무진동, 저에너지 소모에 의한 효과적인 제습을 할 수 있음을 확인할 수 있었다.

  • PDF

Laser 프린터용 고압 가변 전원특성에 관한 연구 (A Study on the Characteristic of Variable High Voltage Power Source for Laser Printer)

  • 채영민;조종화;권중기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.110-114
    • /
    • 2003
  • In this paper, a new self-oscillated type high voltage charger controller circuit is proposed, which has variable constant current source characteristics to improve charge characteristic of charger roller. The proposed control method enables high quality printing characteristics regardless of the circumstance change such as ambient temperature or humidity by changing the current reference signal. To verify the proposed control method various experiments are performed.

  • PDF

Laser 프린터용 고압 순시 전류제어형 전원특성에 관한 연구 (A Study on the Characteristic of High Voltage Type Instantaneous Current Source for Laser Printer)

  • 채영민;조종화;권중기;한상용
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.105-111
    • /
    • 2004
  • 본 논문에서는 온도나 습도 등 주변 환경변화와 무관하게 항상 최적의 레이저 프리터의 출력특성을 유지하기 위한 OPC(Organic Photo Conductor)용 고압 전류형 전원특성에 관한 논문이다. 제안된 제어방식은 기존의 정전압 제어방식이 가지는 단점인 온도나 습도 및 OPC의 분포저항 변화에 따른 출력전류 변동으로 OPC 표면에 일정한 전위를 형성하는 것이 용이하지 않은 단점을 개선하고, 주변환경 변화요인을 프린터 주제어기에서 감지하여 최적의 출력전류 기준신호를 출력하고, 이 기준신호에 따라 최종 출력전류가 제어되어 일정한 화상상태가 유지되도록 제어하는 제어방식으로 실험을 통하여 제안된 제어방식의 타당성을 검증하였다.

병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계 (Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital)

  • 조문택;이충식;백종무
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.127-134
    • /
    • 2011
  • 본 논문에서는 온도와 습도 및 냉 난방을 조절하여 건물 내의 쾌적한 환경을 제공하기 위한 승압쵸퍼와 PWM 전압형 인버터로 구성된 태양광 발전 시스템을 제안하였다. 이 시스템은 안정된 변조를 위해 원칩 마이크로프로세서를 사용하여 동기신호와 제어신호로 처리하였다. PWM 전압형 인버터와 위상의 동기를 위하여 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 연계할 수 있게 하였으며, 건물이나 병원 등 특정 건물의 온도 및 습도센서에 적용하여 양호한 동특성을 얻을 수 있었다. 또한 시스템에 적용한 결과 고역률과 저고조파 출력을 유지함으로써 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어하여 좋은 결과를 얻을 수 있었다.

문화재 전시 공간에 대한 활성탄의 습도 제어 및 유해가스 제거 효과 연구 (The Effects of Humidity Control Capability and Removal Toxic Gases of Activated Carbon to the Display Environment of Cultural Properties)

  • 강새롬;최유리;강대일
    • 보존과학회지
    • /
    • 제30권2호
    • /
    • pp.235-241
    • /
    • 2014
  • 본 연구에서는 활성탄의 문화재 전시 환경에 대한 습도 및 유해물질 제어 능력을 확인하고자 하였다. 흡 방습 성능 실험 결과, 저습과정(RH $30{\rightarrow}55{\rightarrow}30%$)에서는 박물관에서 주로 사용되는 Silica계 조습제에 비해 활성탄의 흡습량이 많은 반면 방습량은 적었다. 흡습속도는 활성탄이 Silica계 조습제에 비해 빠르고 방습속도는 Silica계 조습제가 빨랐다. 중습과정(RH $50{\rightarrow}75{\rightarrow}50%$)에서는 활성탄에 비해 Silica계 조습제의 흡습량이 근소하게 많았으며 방습량은 비슷하게 나타났다. 흡 방습 속도는 활성탄의 흡습 속도가 Silica계 조습제에 비해 빠르고 방습속도는 큰 차이를 보이지 않았다. 유해물질 흡착 실험에서는 활성탄을 적용한 환경이 Silica 계 조습제를 적용한 환경에 비해 Formaldehyde의 농도가 낮았다.

여름철, 파프리카 재배온실에서 실내환경조절 시스템과 건구온도 분포에 관한 연구 (A study on Distribution of Dry Bulb Temperature and Indoor Environment Control System of Paprika Greenhouse in Summer Season)

  • 공성훈
    • 태양에너지
    • /
    • 제19권1호
    • /
    • pp.59-65
    • /
    • 1999
  • The zone of greenhouse in Korea increase on a scale yearly. Particularly, greenhouse take up a important value on the agriculture economy. Greenhouse of scale, material, heating system, and drain is progressing to industrialization. The dry bulb temperature, humidity, photosynthesis and so forth are necessary to maintain environment control of greenhouse. The dry bulb temperature among them greatly affects growing of a plant. The purpose of this study is to analyzed the indoor environment control system and the characteristic of dry bulb temperature distribution on a large scale greenhouse in summer season.

  • PDF

액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구 (Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System)

  • 이수동;박문수;정진은;최영석
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Electrostatic suspension of glass plate

  • Jeon, Jong-Up;Woo, Shao-Ju;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.267-270
    • /
    • 1996
  • This paper reports about the successful suspension of a glass plate by electrostatic forces. In order to implement a stable suspension, the electrostatic forces exerted on the glass plate are actively controlled on the basis of the gap lengths between the glass plate and the stator electrodes. In this paper, the dynamic model of the suspension system and the influence of the resistivity of glass on the system stability are described, followed by stator electrode design, the experimental apparatus and a stabilizing controller. Experimental results show that the glass plate can be suspended at a gap length of about 0.3 mm. The influence of air humidity on the suspension initiation time, and the lateral dynamic characteristic are also described.

  • PDF

Noise Reduction of Muffler by Optimal Design

  • Oh, Jae-Eung;Cha, Kyung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제14권9호
    • /
    • pp.947-955
    • /
    • 2000
  • This paper proposes an optimal design scheme to improve the muffler's capacity of noise reduction of the exhaust system by combining the Taguchi method and a fractional factorial design. As a measuring tool for the performance of a muffler, the performance prediction software which is developed by Oh, Lee and Lee (1996) is used. In the first stage of a design, the length and radius of each component of the current muffler system are selected as control factors. Then, the $L_{18}$ table of orthogonal arrays is adopted to extract the effective main factors. In the second stage, the fractional factorial design is adopted to take interactions into consideration, which the $L_{18}$ table of orthogonal arrays can not consider. For an optimal design, the $L_{27}$ table of orthogonal arrays with main and interaction effects is proposed and the noise factors such as temperature, background noise and humidity are analyzed for more efficient design simultaneously.

  • PDF