• Title/Summary/Keyword: humidity condition

Search Result 1,057, Processing Time 0.508 seconds

Crystal form of SKP1080 (SKP1080의 결정형)

  • Sohn, Young-Taek;Lee, Kyoung-Ee
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.289-293
    • /
    • 2000
  • Three polymorphic modifications and one amorphous form were prepared by recrystallization under various conditions and characterized by DSC and X-ray crystallography. At $37{\pm}0.5^{\circ}C$, the polymorphic modifications showed significant differences in the dissolution rate. The dissolution rate of Mod. 4, amorphous form, was faster than that of other polymorphic modifications. When all modifications were stored at 52% RH, 95% RH, and in silica gel desiccator, amorphous form was transformed at 95% humidity condition.

  • PDF

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

A study on the Architectural Condition and Cases of BIPV-module for Roof (지붕일체형 PV모듈의 건축특성 및 적용사례 분석연구)

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.49-56
    • /
    • 2006
  • The roof among the outer surfaces of buildings is an optimum place to install PV since it is the best favorable part in the building to be exposed to day light. Especially, in case of module of BIPV for Roof, it should have essentially the functions of both electricity generation and roof-finish as a construction material. The followings are the results of the study which has analyzed the architectural conditions and applications thereof at the job site. -The aesthetic function of BIPV module is very important because the roof, mostly located at the top of the buildings, is easily recognized and affects outer interior design of the building a lot. -The heat proof of BIPV for Roof could affect the energy consumption through the roof having a wide area. -For architectural condition to the weather, the roof has to ensure the stability of the weather, humidity proof, and airtightness to the wind respectively. -For architectural condition of the structure, endurance by physical power such as stability of both combining and fixing and transfer of load should be ensured. -For residents protection, it has also architectural functions to secure for the space and shield ozone, UV and noxious substances. -Through its practical applications, It is already confirmed that there are various types of BIPV modules overseas and its application has been proved successfully.

Changes in the Characteristics of Textile Products according to the Storage Environmental Condition for Sustainable Care (섬유제품의 지속가능한 관리를 위한 보관환경에 따른 특성변화 연구)

  • Kim, Jeong-Hwa;Lee, Sun-young;Lee, Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.3
    • /
    • pp.390-406
    • /
    • 2022
  • This study aims to establish the optimal environmental conditions for storing textile products. Four textile products (cotton, wool, nylon, cotton/polyurethane) were used to produce experimental fabrics according to artificial contamination and washing conditions. Each fabric was subjected to three environmental conditions (A: 20-25℃/20% RH, B: 20-25℃/50% RH, C: 30-35℃/65% RH) for 4-12 weeks. Changes in textile characteristics include tensile strength, wrinkle recovery rate, and odor intensity. Results show that the change in tensile strength for the four test fabrics slightly decreased with a storage time of 4 to 12 weeks. The wrinkle recovery rate of the fabrics was the lowest under the C condition. UV exposure causes a substantial decrease in the tensile strength of the textiles. The change in odor characteristics was the highest for the odor intensity in the C condition. For storing textile products for sustainable management, it is desirable to maintain a temperature of 20 to 25℃ with a relative humidity of 50% RH or less and to provide ventilation in an enclosed storage space that can also block UV rays.

Changes of Storability and Quality Characteristics of 'Autumn Sense' Hardy Kiwifruit According to Ethylene Treatment and Storage Condition (에틸렌 처리와 저장조건에 따른 '오텀센스' 다래의 저장성 및 품질특성 변화)

  • Oh, Sung-Il;Kim, Chul Woo;Kim, Mahn-Jo
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.3
    • /
    • pp.368-374
    • /
    • 2014
  • This study was investigated the changes of storability and quality characteristics of 'Autumn Sense' hardy kiwifruit according to ethylene treatment and storage condition. In the results of investigation of changes in hardy kiwifruit quality during storage period, hardness of ethylene treated hardy kiwifruit during 48 and 96 hours was rapidly decreased, but soluble solid content was rapidly increased with the passing of storage period in all treatment groups. The total acid was estimated from 0.7 to 1.4% with storage period in all treatment groups. In the results of investigation of the weight loss rate, ethylene treated hardy kiwifruit during 48 hours was the highest 30.9% in storage at $20^{\circ}C$ and lowest 5.9% in storage at $2^{\circ}C$ with a relative air humidity of about 90% during storage at 24 days. Ethylene treated hardy kiwifruit during 96 hours was decrease 29.4% in storage at $20^{\circ}C$, 20.7% in storage at $4^{\circ}C$, 12.1% in storage at $2^{\circ}C$, and 6.0% in storage at $2^{\circ}C$ with a relative air humidity of about 90% during storage at 22 days. The taste of hardy kiwifruit during storage was reduced to increase in all treatment groups. Particularly, storage at $20^{\circ}C$ was rapidly reduced to increase in the early storage and storage at $2^{\circ}C$ with a relative air humidity of about 90% was decrease after storage at 18 days. The rotten rate during storage was increased in all treatment groups, storage at $20^{\circ}C$ was after storage at 2 days and storage at $2^{\circ}C$ with a relative air humidity of about 90% was rapidly increased after storage at 16 days. Thus, it can be recommended that storage at $2^{\circ}C$ with a relative air humidity of about 90% is good to maintain quality. Also, we will decide optimal storage condition and after-ripening time of 'Autumn Sense' hardy kiwifruit.

Effect of Air Temperature and Relative Humidity during Flowering on Pollen Germination of Oriental Melon (Cucumis melo L. var. makuwa Makino) (개화 시 기온 및 상대습도가 참외의 화분발아에 미치는 영향)

  • Im, Kyung Ran;Suh, Jun Kyu
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.13-18
    • /
    • 2013
  • This study was conducted to examine the effect of temperature and relative humidity (RH) that might affect the pollen germination rate and pollen tube length in oriental melon. The experiment was performed using three cultivars namely 'Mallijangseong', 'Ohbokggul', and 'Joeundae' wherein environmental conditions were controlled by three different temperatures $15^{\circ}C$, $25^{\circ}C$, and $35^{\circ}C$ and also three RH levels 30%, 60%, and 90%. Based on the results in terms of temperature, true to all cultivars, plants exposed to $25^{\circ}C$ had the highest pollen germination rate while plants exposed to $15^{\circ}C$ had the lowest. Among the three cultivars, 'Mallijangseong' had the highest in terms of pollen germination rate, followed by 'Ohbokggul', and lastly was 'Joeundae' that showed the lowest germination rate. In the case of pollen tube length, pollen exposed under $35^{\circ}C$ showed the longest tube length, followed by pollen under $25^{\circ}C$, and pollen under $15^{\circ}C$ remarkably had the shortest tube length. Across the three cultivars 'Ohbokggul' had the longest pollen tube length. In the case of RH, pollen germination response among three cultivars depends on the humidity conditions but based on the results, there was no significant differences although high germination rate was observed in highest humidity condition. Between each cultivar, 'Ohbokggul' had the lowest pollen germination rate compared with 'Mallijangseong' and 'Joeundae' after exposure to different RH conditions wherein pollen germination showed significant differences among treatments. The pollen collected under 60% RH had the longest pollen tube length, followed by 30%, and the shortest was under 90% RH. In general, 'Ohbokggul' had the longest pollen tube length while 'Joeundae' had the shortest among the three cultivars.

The Wearing Effect of Sport Underwear -Focusing on the Loss of Weight and Amount of Sweat according to the Materials- (운동용 속옷의 착용효과 -소재별 발한량과 체중감량을 중심으로-)

  • Na, Mi-Hyang;Kim, Mi-Sun;Jung, Bock-Hee
    • Korean Journal of Human Ecology
    • /
    • v.11 no.3
    • /
    • pp.273-285
    • /
    • 2002
  • Three materials for sport underwear were manufactured by order for study, and among them, suitable material in order to perform an experiment on the effect of wearing was adopted. The results are as follows: The result of wearing an experimental clothes for sports manufactured as a foundation-type underwear for sports showed that if the same compositional materials were applied, laminating material had higher rate than that of others in the amount of sweat. Concerning relative humidity in clothes and the amount of sweat absorbed in clothes among the two kinds of materials which were produced by laminate, material 2(nylon+modal) was statistically exerts higher influence on the amount of sweat. The humidity in clothes keeps the optimal condition of 59.8%, and breast part showed the highest relative humidity. The material 2(nylon+modal) showed the highest comfortableness, the sense of warmth, humidity and voluminousness, and the sense of pressure. Follow-up survey revealed that in case of material 2, higher amount of sweat than that of the group objects in its early phase, and the amount of sweat varies from individuals. The temperature in clothes of folded parts of experimental clothes and maximum surface temperature was equivalent to that of average skin. With the lapse of time, the weight decreased of 11.03% in maximum, and 3.12% in minimum. The amount of change in the girth was greater in part of body frame than that of limbs, and especially, navel and waist part showed high decrease, and upper breast, breast and the largest part of abdomen showed relatively low decrease. The above experiment revealed that materials for suitable to the underwear for sports for loss of weight by an exercise should be made of doubled-nylon and modal, along with the laminate processing, which heightens the amount of sweat. Thus, wearing an experimental wear gave satisfaction in the view of the beauty of appearance as it did not discharge flowing secretion to the outside at the time of exercise.

  • PDF

Effects of Storage Conditions on Qualities of Buttercup Squash (Kabocha) (밤호박의 저장 온도와 습도가 품질에 미치는 효과)

  • Han, Jin-Suk;Chung, Moon-Cheol;Kim, Sung-Ran
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.644-651
    • /
    • 2007
  • To establish the optimum conditions for storing buttercup squash, we examined the effectiveness of several storage methods and the quality of the squash under various storage conditions, including temperature (12 and $20^{\circ}C$) and relative humidity (20, 40, 60, and 80%). The spoiling rate of the squash was affected more by the storage temperature than the relative humidity, and the squash stored at $20^{\circ}C$ started to be deteriorated after 20 days of storage. At $20^{\circ}C$, soluble solid content gradually increased until 20 days of storage, and then it tended to decrease. The L-value had a tendency to increase with days of storage, and the a- and b-value also increased after 40 days. In addition, the color changes were great when the squash was stored at high temperature and high relative humidity. The total pectin content increased until 20 days at $20^{\circ}C$, and then it decreased, but less change was observed in the squash stored at $12^{\circ}C$. Overall, the results showed that storage at $20^{\circ}C$ after field curing resulted in excessive weight loss, color loss and poor eating quality, as well as a high level of decay (approximately 70%) after 40 days. However, the squash stored at $12^{\circ}C$ and 60% RH (relative humidity) showed less degreening and had a reduced level of decay, below 10%.

Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space (실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향)

  • Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.