• Title/Summary/Keyword: humidity condition

Search Result 1,057, Processing Time 0.034 seconds

Effects of Some Environmental Factors on Japanese Yew (Taxus cuspidata Sieb. et Zucc.) (몇 발근환경인자(發根環境因子)가 주목삽수(揷穗) 발근(發根)에 미치는 효과(効果))

  • Kim, Chang Ho;Nam, Jung Chil
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • The purpose of this experiment lies in finding the most appropriate cutting condition of Taxus cuspidata Sieb. et Zucc. which has been considered valuable tree species in gardening. Statistical analysis was focused on the comparison of the average ratios of rooting between greenhouses and fields, based on the observation rooted autogenis. To conduct this survey, hardwood cutting of Taxus cuspidata Sieb. et Zucc. were performed at both places of experiment above on April 20, 1982 with rooting results calculated on October 31, 1982. After formation of cuttings, it was soaked in IBA 200 ppm for 12 hours and than put in a bed. A summary of the result is presented as follows; 1) Cutting at the greenhouse showed higher average rate of rooting than at fields. Same tendency was found regardless of the differences in treatment. 2) It was clear that IBA-treatment contributed remarkably to causing higher average rooting rate. As an evidence, when twenty centimeter cuttings were inserted sandy media, IBA-treated area resulted in eighty six percent of average rooting rate, as compared with only twenty three percent in nontreatment case. In case of field cutting, IBA-treatment brought about fifty three percent of rooting in comparison with eleven percent nontreatment. 3) When sandy soil, loam and brown soil were separately used as cutting media, the highest rooting rate was found in case of sandy soil, without any difference between the two experimental places above. 4) As a result of the analysis to seek the impact of the length of cuttings on rooting, the range of length form fifteen to twenty centimeter was apparently most appropriate. It was also found that the rate of rooting declined beyond twenty five centimeter. 5) Two kinds of rooting pattern were observed. One was the case that callus cell lump was created on the lower cut side of cuttings. Importantly, root radical were formed inside the lump to influence the germination of root system. The other relates to the case that adventitious root which look like lateral roots appeared at the stem region. In abstract, first, sandy soil was effectively recommended in case of hardwood cutting in April. Second, the most appropriate length of cuttings ranged between fifteen and twenty centimeters. Third, high density IBA treatment was clearly effective. Forth, for proper environmental management, both pre-disinfection of sail by sterilizer and maintenance of high relative humidity were essentially required.

  • PDF

The Effects of Salt Levels and Drying Period on Physicochemical and Sensory Parameters of Dry-cured Ham Ripened in Controlled Condition (소금과 건조기간이 발효실에서 제조된 건염햄의 이화학적 및 관능적 특성에 미치는 영향)

  • Seong, Pil-Nam;Cho, Soo-Hyun;Kang, Geun-Ho;Kim, Jin-Hyoung;Park, Beom-Young;Jeong, Da-Woon;Kim, Byeong-Kyeong;Jung, Jae-Hong;Jeong, Seok-Geun;Kim, Dong-Hoon
    • Food Science of Animal Resources
    • /
    • v.31 no.6
    • /
    • pp.914-920
    • /
    • 2011
  • The aim of this study was to analyze the effects of salt and drying period on the physicochemical and sensory parameters of dry-cured ham ripened in a controlled condition. In this study, three treatments were performed: High salt group (HS), salted with 7 g $kg^{-1}salt$ (w/w); Middle salt group (MS), 5 g $kg^{-1}salt$ and; Low salt group (LS), 3 g $kg^{-1}salt$. Three conditions of drying period were applied including 180, 270 and 360 d at $19^{\circ}C$ and 65% relative humidity, and the physicochemical character and sensory properties of M. biceps femoris were investigated. pH and water activity were decreased with increasing drying period, and the pH of LS was higher than that of other treatments (p<0.05). When increasing the drying period, the hardness of HS was steadily raised for 360 d, whereas LS and MS hardened between 180 and 270 d (p<0.05), and there was no significant difference after 270 d. Cohesiveness, glumness and chewiness had a positive relationship with the drying period. Also, springiness, glumness and chewiness showed a positive relationship with salt level. Chroma and hue value were improved by increasing the salt level. As the drying period increased, the rate of hardness and flavor intensity was increased. In general, this research can be used as essential information for the mass production of dry cured ham.

Effect of Temperature on the Quality and Storability of Cherry Tomato during Commercial Handling Condition (유통중 온도관리가 방울토마토의 품질과 저장성에 미치는 영향)

  • Islam, Mohammad Zahirul;Kim, Young-Sik;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.88-94
    • /
    • 2012
  • This study was carried out in order to investigate the effect of temperature of treatment and storage on the longevity of 'Unicorn' tomatoes of light red maturity stage during commercial handling conditions encountered while exporting over long distances. Tomato stored at $5^{\circ}C$ and $11^{\circ}C$ temperature with 85% relative humidity by pre-treating handling temperature that was using from field to before shipment as a winter temperature $5^{\circ}C$, spring temperature $11^{\circ}C$ and summer temperature $25^{\circ}C$ for 3 days. On the final storage day, $25^{\circ}C/11^{\circ}C$ (treated/stored) tomatoes showed the highest respiration and ethylene production rate; whereas the lowest respiration and ethylene production rate was found for $5^{\circ}C/5^{\circ}C$ treated and stored tomatoes. Tomatoes treated and stored at $5^{\circ}C/5^{\circ}C$ showed higher marketability, without evidence of fungal rot, decay or spots for 23 days. The fresh weight loss under all treatment conditions increased gradually during $5^{\circ}C$ and $11^{\circ}C$ storage temperatures. The higher firmness and soluble solids were determined from $5^{\circ}C/5^{\circ}C$ and $5^{\circ}C/11^{\circ}C$ treated and stored tomatoes repectively, than from others tomatoes on the final day of storage. In addition, $5^{\circ}C/5^{\circ}C$ tomatoes showed higher vitamin C contents than tomatoes stored at other temperatures, on the final day of storage. As the ripening and storage period progressed, the titratable acidity increased, but declined (P < 0.05) thereafter, due to over ripe tomatoes under all treatment conditions. These results show that $5^{\circ}C/5^{\circ}C$ treated and stored light red maturity stages of 'Unicorn' tomatoes are optimum to export because they show the highest storability and marketability. Moreover, the marketability of light red maturity stage of 'Unicorn' tomato maintained for 2 weeks in $25^{\circ}C/11^{\circ}C$ treated and stored temperature that might be the export temperature from Korea to Japan in summer season. This research result could be useful in helping tomato growers and exporters to get optimum market value by satisfying the buyer and consumer with a fresher product.

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

Development of Carbonization Technology and Application of Unutilized Wood Wastes(II) - Carbonization and it's properties of wood-based materials - (미이용 목질폐잔재의 탄화 이용개발(II) - 수종의 목질재료 탄화와 탄화물의 특성 -)

  • Kong, Seog-Woo;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.57-65
    • /
    • 2000
  • Objective of research is obtain fundamental data of carbonized wood wastes for soil condition, de-ordorization, absorption of water, carrier for microbial activity, and purifying agent for water quality of river. The carbonization technique and the properties of carbonized wood wastes(wood-based materials) were analyzed. Proximate analysis showed the wood-based materials contains 0.37~2.27% ash, 70~74% volatile matter, and 17~20% fixed carbon. As carbonization temperature was increased, the charcoal yield was decreased. However, no difference in charcoal yield was found due to time increase. The specific gravity after the carbonization decreased about 30~40% comparing to green wood. The charcoal had 1.08~4.18% ash, 5.88~13.79% volatile matter, and 80.15~90.94% fixed carbon. The pH of plywood and particleboard(pH 9 at $400^{\circ}C$, pH 10 at $600^{\circ}C$ and $800^{\circ}C$) made charcoals was higher than that of fiberboard. The water-retention capacity was not affected by the carbonization temperature and time. The water-retention capacity within 24h was about 2~2.5 times of sample weight, and the Equilibrium moisture content(EMC) became 2~10% after 24h. EMC of charcoal from the thinned trees were 9.40~11.82%($20^{\circ}C$, RH 90%), 6.87~7.61%($20^{\circ}C$, RH 65%), and 1.69~2.81%($20^{\circ}C$, RH 25%). EMC of charcoal from the wood-based materials under $20^{\circ}C$, relative humidity(RH) 90% was similar to EMC of charcoal from the thinned trees(9~11 %). However, under $20^{\circ}C$, RH 25.65%, EMC of charcoal from the wood-based materials were higher(2~3%) than EMC of charcoal from the thinned trees. Every charcoal from the wood-based materials fulfilled the criteria in JWWA K 113-1947.

  • PDF

Light Quality and Photoperiod Affect Growth of Sowthistle (Ixeris dentata Nakai) in a Closed-type Plant Production System (밀폐형 식물생산시스템에서 광질과 광주기에 따른 씀바귀의 생육)

  • Kim, Hye Min;Kang, Jeong Hwa;Jeong, Byoung Ryong;Hwang, Seung Jae
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.67-76
    • /
    • 2016
  • This study was conducted to examine the optimal environmental condition for promoting the growth of sowthistle as affected by light quality and photoperiod in a closed-type plant production system. Seeds were sown in 240-cell plug trays and then germinated for 3 days at a 24-hour photoperiod in a closed-type plant production system with LED lights (R:B:W = 8:1:1). Seedlings were transplanted and grown under 3 types of LED (R:B:W = 8:1:1, R:W = 3:7, or R:B = 8:2) and 4 photoperiods (24/0, 16/8, 8/16, or 4/20 hours) with $230{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ light intensity at a density of $20cm{\times}20 cm$. The experimental design was a randomized complete block design. Plants were cultured for 40 days un der the condition of $21{\pm}2^{\circ}C$ and $70{\pm}10%$ relative humidity after transplanting. Plants were fed with a recycling nutrient solution (pH 7.0 and EC $2.0dS{\cdot}m^{-1}$) contained in a deep floating tank. Fresh weight and dry weight of shoot or root, leaf length, and leaf area were the greatest in the photoperiod of 24/0 (light/dark) with RW LED. The highest number of leaves occurred in the photoperiod of 16/8 (light/dark) with RB LED, while the incidence of tip burn was higher in the photoperiod of 24/0 (light/dark) compared to the other treatments. Chlorophyll value was the highest in the 16/8 (light/dark) photoperiod and there was no significant difference by light quality. Chlorophyll fluorescence was the lowest in the photoperiod of 24/0 (light/dark) compared with other treatments. Therefore, in terms of economic feasibility and productivity for Ixeris dentata Nakai cultivation in a closed-type plant production system, the results obtained suggest that plants grew the best when kept in a photoperiod of 16/8 (light/dark) and light quality of combined LED RW (3:7).

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

THE MORPHOLOGICAL OBSERVATION OF HUMAN PERIODONTAL LIGAMENT CELLS ATTACHMENT AND SPREADING ON THE SURFACE OF SLIDE GLASS (치주인대세포의 부착과 전개에 관한 형태학적 관찰)

  • Lee, Jin-Mi;Suh, Jo-Young;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.97-108
    • /
    • 1993
  • One of the important initial events required for periodontal regeneration is the attachment and subsequent spreading of periodontal ligament cells on the root surface. The purposes of this study is to investigate the attachment and spreading pattern of human periodontal ligament cell on the surface of glass slides. After establishment of a cell line of the primary cell culture from the periodontal ligament of 1st premolar teeth which were extracted for the purpose of orthodontic treatment, author dispersed the cells at $5{\times}10^3\;cells/ml$ into the each 35mm culture petri-dish containing 2 glass slides. To observe the morphological changes of the cells which attached to the surfaces of glasses at every designed time schedule, author used the inverted phase contrast microscope and scanning electron microscope. During the whole experiment culture condition was at $37^{\circ}C$, 100% Humidity, 5% $CO_2$ gas incubator. The following results were obtained. Periodontal ligament cells showed spherical outline and started to attach to glass surface by basal sytoplasmic extension after 10min in culture. After 30min in culture, periodontal ligament cells were attached to glass surface by well - developed filopodia which protruded from the lamellipodia. The cell surface is covered with bubble-like structures and occasional microvillus can be seen with diffculty among these structures. After 1.5hr in culture, peridontal ligament cells shhowed radially well-spread cytoplasm and the nucleus was centered on its cytoplasm. Unspread central region of the cell was covered with numerous microvilli. The change of cell attachment and spreading pattern was manifest at 6hr in culture. At this time, periodontal ligament cell showed elongated outline and an oval-shaped nucleus. After 12hr in culture, periodontal ligament cells showed more stretched fibroblast-like appearance with polarity. Two long lamellipodia can be seen around the both terminal ends of cells. After 24hr in culture, periodontal ligament cells showed spindle shapes and an oval-shaped nucleus was slanted toward one side of the cell.

  • PDF