• Title/Summary/Keyword: humidity and temperature inside clothing

Search Result 38, Processing Time 0.025 seconds

A Study on the Wear Sensation Cellulose Fabric in Summer (여름철 셀룰로오스 섬유 의복의 착용감에 관한 연구)

  • Kwon Soo-ae;Lee Soon-won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.1 s.26
    • /
    • pp.81-91
    • /
    • 1988
  • The purpose of this study is to investigate the physiolosical responses and subjective wear sensation to the clothes with different cellulose composition. The experimental garments were four types of cellulosic fabrics, respectively composed of $100\%$-cotton, $100\%$-Rayon, cotton/Flax 85/15, and rayon/Flax 85/15 (weft blended), were sewn in blouses with half-length sleeves. Four healthy women were chosen for this experiment. The condition of the experimental room were in two environments: Temp., $25{\pm}1^{\circ}C$, R.H. $60{\pm}3\%$ and Temp., $30{\pm}1^{\circ}C$, R.H. $70{\pm}3\%$, and air velocity was maintained at 0.25 m/sec. The results are as follows. 1) At $25^{\circ}C$, rayon blouse showed the pleasantest feeling because of its excellent humidity sensation and tactile sensation. At $30^{\circ}C$, rayon and flax blended blouse showed most comportable sensation. In both environments, blouse of $100\%$ cotton showed the least pleasant because of high vapor pressure inside the blouse and bad tactile sensation. 2) Vapor pressure inside the blouse and tactile sensation play the most impotant role in comfort. Consequantly the blouse made of $100\%$-cotton which bring low air permeability, moisture regain and water vapor permearbility showed more unpleastness than rayon blouse because it raises temperature, relative humidity and vapor pressure inside the blouse under the hot circumstances In the conditions with much sweat, rayon and flax blended blouse with high stiffness increases comfort better than $100\%$ rayon because the former prevents sticking to the skin.

  • PDF

Effects of Fiber Type and Blouse Design on the Clothing Microclimate (의복재료와 상체부 의복형태변화가 의복내기후에 미치는 효과)

  • Kim Ok Jin;Kim Yong Ser;Shin Youn Sook;Lee Young Suk;Chung Myung Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.1 s.33
    • /
    • pp.20-30
    • /
    • 1990
  • In order to investigate the mechanism of the formation of clothing microclimate with different blouse designs and materials, physiological and subjective sensational changes were measured. Experimental clothing were four types of blouse made of $100\%$ cotton, $100\%$ regular polyes­ter, and $100\%$ hygroscopic polyester. Four types of box style blouse were with stand collar and long sleeve, with stand collar and sleeveless, with long sleeve and collarless, and sleeveless and collarless. Five healthy female were chosen as subjects. Experiments were carried out in the environ­mental chamber controlled at $28{\pm}1^{\circ}C$ , $70{\pm}5\%$ RH. and still-air condition for SO min. The skin temperature (9 spots), oral temperature, humidity inside chest, and subjective sensations were measured. Obtained results are: I) Material which is capable of absorbing sweat effectively and transfering moisture rapidly made a comfortable feeling, because cloth­ing humidity is increasing slowly at this material. 2) During exercise period, covered arms have more influenced on thermal comfort than a covered neck.

  • PDF

A Study on Bedquilts During Sleeping on Ondol in Winter (겨울철 온돌난방에서의 이불에 관한 연구)

  • Kweon, Soo Ae;Lee, Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.291-299
    • /
    • 1993
  • In this study, bedclimate was investigated depending on three bedquilts used on ondol in winter. The environmental room condition and the ondol surface temperature were maintained $20{\pm}1^{\circ}C$, $50{\pm}3%R$. H and $30{\pm}1^{\circ}C$, respectively. The materials of the experimental quilts were not different from each other. But the weights of cotton filler were 1.5, 3.0, and 4.5kg for the bedquilts. Two healthy young women were subjected for seven hour's sleep with two replications for this study. The results are as follows. 1) The range of temperature under the mattress was higher($38.5{\sim}43.2^{\circ}C$) than that of the temperature on the mattress($32.4{\sim}37.0^{\circ}C$) or that of the temperature inside the bedquilts($30.2{\sim}34.5^{\circ}C$). The humidity inside the bedquilts was 40~73%R.H. 2) The range of bedclimate which subjects feel comfortable were $33.6{\sim}37.1^{\circ}C$ on the mattress, $30.2{\sim}33.6^{\circ}C$, 42~67%R.H. inside the bedquilts. At this range, the mean skin temperature of the subjects was was $34.7{\sim}35.6^{\circ}C$. 3) When there was heating, the weight of mattress increased due to evaporation by heat from below, while wehght of other bedding increased. 4) The lower limbs are noted to be a good representative for the prediction of the skin temperature during sleep. 5) The thicker the bedquilt, the warmer and more humid the bedquilt, which induce frequent body movement during sleep, hence inferior comfort properties of bedquilts.

  • PDF

A Study on The Development and Evaluation of Mine Detective Gear (지뢰 탐지용 방호복 구성과 방호성능 및 착용감 평가)

  • 손부현;최혜선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.4
    • /
    • pp.707-718
    • /
    • 2001
  • The purpose of this study is to evaluate a newly developed protective suit with the fragments of grenade. The protection efficiency should be strengthened upon the degree of wound. The fragment weight of the used grenade was measured and the kinetic energy of the maximum speed of the fragments in the field test was 137.7J and this could be the protective efficiency test by the multitude fragments in less than 0.031g of the M16A1. The panel inserted to the new demining suit has protection rate of 100% within the distance of 1m and sample II has protection rate of 100% only beyond the distance of 5m. The test showed that the protection rate on the protective suit of the existing garment was comparatively high, however, the protection rate of the sleeve part was very low. The new demining suit through the research demand some complementary measures to lower the temperatures in ear, average skin temperatures, and the temperatures-humidity inside the clothing for summer climate condition, It showed that 30 minutes of rest on the clothing was difficult to go back to the original condition. But in winter climate condition, there was no problem in the temperature, humidity, and comfort to go back to the original condition during the rest and was better in warmth.

  • PDF

Development and Evaluation of Protective Clothing for Rose Farmers

  • Chae, Hyeseon;Kim, Sungchul;Oh, Youngsoon;Lee, Kyungsook;Kim, Hyocher;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.3
    • /
    • pp.427-436
    • /
    • 2016
  • Protective clothing developed for rose flower farmers has been evaluated to improve the working conditions. The requirements of rose farmers were first identified to design protective clothing for farmers working with thorny plants. A fit test was conducted to assess the thermal comfort and protective function against thorn pricking to compare and evaluate the usability of developed experimental clothing with existing working clothes. Based on the survey results of rose farmers' requirements, protective clothing was designed in the form of an apron (which was the most preferred after gloves) with a pattern designed for the production of experimental clothing. For the developed protective clothing, the strap and buckle closure method was selected to open the back of the body as much as possible; in addition, sleeves were made in the attachable form of a half-sleeve to protect the arms from the thorns. The fit test of the developed protective clothing and existing working clothes revealed the temperature and humidity inside the developed protective clothing to be significantly different in the back compared to existing work clothes. In addition to thermal sensations, the subjective humidity sensations were statistically significant different in the developed protective clothing compared to existing work clothes. The subjective protective function for thorn pricking was also found to be satisfactory.

A Study on Clothing Weight and Cornell Medical Index in Elderly Women (노인여성의 착의량과 건강관련변인)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.18 no.5
    • /
    • pp.1087-1092
    • /
    • 2009
  • From the environmental adaptation point of view, the clothing habits made by the thermal sensation and clothing weight of elderly women have changed according to the thermal sensation and health condition. The purpose of this study was to obtain the basic data for developing healthy and comfortable clothing for elderly women. Clothing weight, thermal sensation, clothing microclimate, resistance to cold and heat of 198 elderly women in Taejeon were surveyed from October 9, 2007 to October 19, 2007. 1. Clothing weight per body surface area was $830.4g/m^2$ of total clothing weight, $242.8g/m^2$ of underwear clothing weight, $617.3g/m^2$ of outerwear clothing weight, $419.8g/m^2$ of upper clothing weight, and $420.4g/m^2$ of lower clothing weight. 2. More than 90% of the respondents replied that they felt comfortable when the temperature inside the clothing was $33.5^{\circ}C$ and humidity inside the clothing was 30.2%. 3. The elderly women were more sensible to cold than to hot, those who felt cold had a tendency to wear heavier clothing. 4. The appeal rate for physical pain of older and lower income people, especially those with an income under 1,000,000 won, was higher than that of others. On the other hand, the lower the subjective economic level, the younger they were, and the more the monthly average income was, the higher the rate of mental pain. 5. The heavier the total clothing weight was, the higher the appeal rate for general pain.

Evaluation of Clothing Comfort and Anti-atopy Properties by Human Wear Test -Focused to Inner Wear Natural Dyed with Bamboo Charcoal- (인체착용실험에 의한 쾌적성 및 항아토피 성능평가 - 대나무숯 천연염색의류를 중심으로 -)

  • Kim, Sung-Hee;Shin, Youn-Sook
    • Fashion & Textile Research Journal
    • /
    • v.12 no.1
    • /
    • pp.122-128
    • /
    • 2010
  • This study examined several dyeing properties, physiological responses and comfort sensation of cotton knit underwear dyed with bamboo charcoal. The cotton knit underwear dyed with bamboo charcoal and treated with chitosan showed 99.9% antibacterial property and improved deodorization, and colorfastness. Eight children with atopic dermatitis worn underwear dyed with bamboo charcoal during 4 months. Their parents reported fewer itches of children. Wearing cotton knit underwear dyed with bamboo charcoal and non-dyed with bamboo charcoal respectively, these eight children rested for 20 minutes, then exercised for 10 minutes, and then rested for 30 minutes in the room maintained $28{\pm}1^{\circ}C$ and $50{\pm}5%R.H.$ Children's rectal temperature, skin temperature and microclimate inside garment of two types of cotton knit underwear were compared. As a result, the rectal temperature and skin temperature were higher when children were wearing underwear dyed with bamboo charcoal than non-dyed underwear. The microclimate temperature and microclimate humidity at the back of children were lower when children with underwear dyed with bamboo charcoal exercised and recovered.

Physiological and Psychological Effects of Wearing Winter Cap in Elderly Males (고령 남자의 겨울철 모자 착용 효과 -생리·심리적 검토-)

  • Park, Joonhee;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.3
    • /
    • pp.405-415
    • /
    • 2019
  • This study examined the physiological and psychological effects of wearing a winter cap at rest in a cold environment. Seven older males participated in two separate trials: wearing a winter cap (CAP) and non-wearing a winter cap (CON). The experiment was conducted for 60 min in a climatic chamber (air temperature $7.8{\pm}0.3^{\circ}C$ with $43{\pm}2%RH$) with sedentary posture. Microclimate temperature at the vertex of the head was $6.88^{\circ}C$ higher in CAP compared to CON (p<.01). Microclimate humidity at the vertex was lower in CAP than in CON only during the last 5 min (p<.01). Skin temperature at the forehead in CAP was higher than in CON (p<.01). During the last 5 min, rectal temperature was higher in CAP than that in CON (p<.05). Unlike CAP, the heart rate in CON during the last 5 min decreased significantly compared to the initial 5 min (p<.05). Subjects also felt less cold on the head/face in CAP than that in CON (p<.01). The results indicate that wearing a cap for elderly males positively affected body temperature regulation and cardiovascular response in cold environments. The importance of wearing warm hats for elderly males in winter should be emphasized.

Effects of wearing disposable diaper with the endothermic agent on thermal responses of infant (흡열제가 첨가된 일회용 기저귀의 착용이 유아의 온열생리적 반응에 미치는 영향)

  • 성유진;이수원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.4
    • /
    • pp.499-509
    • /
    • 1999
  • This study was carried out to investigate the effects of wearing disposable diaper with the endothermic agent on thermoregulatory response of infant. Five healthy female infants aged about 5 months were taken as a subject of this experiment. Experimental diapers were six kinds of disposable diaper constructed of nonwoven tissue, fluff pulp, super absorbent polymer, back sheet film, leg elastic, and 0g urea(A) 1g urea(B) , 2g urea(C), 3g urea (D), 4g urea(E) 5g, urea(F) respectively. Urea(98% or over purity) was used as an endothermic agent. Experiment was proceeded while infants were sleeping at 27.5$\pm$0.5$^{\circ}C$, 50$\pm$5% R.H, 0.04m/sec. Each disposable diaper's properties was tested. During the experiment rectal temperature skin temperature of 9 areas temperature inside the disposable diapers were measured, the results were as follows : 1) There was not significant difference among the diapers in absorption capacity retention capacity and rewet(p=0.05). The absorption under load was showed to A, B,

  • PDF

Weather Data-Based Coordination Recommendation Smart Wardrobe System (날씨 데이터 기반 코디추천 스마트옷장 시스템)

  • Lee, Tae-Hun;Jeong, Hui;Kwon, Jang-Ryong;Baek, Pil-Gyu;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.729-738
    • /
    • 2022
  • Existing wardrobes have been used only for storing simple clothes. Since it has a function to store clothes, there is only one way to control the environment such as humidity or temperature, and there is only one way to purchase and store items such as a desiccant. In this paper, by increasing the convenience in the existing wardrobe, automatic temperature and humidity control and various convenient functions were added. In line with the smart home market and smart phone application market that have grown over the past several years, along with the development of a wardrobe with sensors, the temperature and humidity control function and other functions inside the wardrobe through Bluetooth pairing between the wardrobe and the smartphone can be customized to the user using a smartphone. Through the clothing selection function and the weather data in the application, we want to implement convenient functions such as the function of recommending clothes in the closet to match the weather.