Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Sheng, Nai-Li;Cheong, Seong-Ir;Lee, Jae-Keun;Park, Jong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF

An Experimental Study for the Effect of Operating Condition of the Air Handling Unit on the Performance of Humidifying Elements (공조기 운전 조건이 가습 소자의 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.326-331
    • /
    • 2018
  • Evaporative humidification using a humidifying element is used widely for the humidification of a building or a data center. The performance of a humidifying element is commonly expressed as the humidification efficiency, which is assumed to be independent of the air temperature or humidity. To verify this assumption, a series of tests were conducted under two air conditions - data center ($25^{\circ}C$ DBT, $15^{\circ}C$ WBT) and commercial building ($35^{\circ}C$ DBT, $21^{\circ}C$ WBT) - using humidifying elements made from cellulose/PET and changing the frontal air velocity from 1.0 m/s to 4.5 m/s. Three samples having a 100 mm, 200 mm, or 300 mm depth were tested. The results showed that the humidification efficiency is dependent on the air condition. Indeed, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. This suggests that a proper thermal model should account for the inlet area, where the amount of moisture transfer may be different from the other part of the humidification element. As the depth of the element increased from 100 mm to 200 mm, the humidification efficiency increased by 29%. With further increases to 300 mm, it increased by 42%. On the other hand, the pressure drop also increased by 47% and 86%.

A study on the steady-state and dynamic performance of polymer electrolyte fuel cells under various external humidification conditions (고분자 전해질 연료전지의 외부가습 조건에 따른 정상상태 및 비정상상태 성능특성 연구)

  • Lee, Yong-Taek;Kim, Bo-Sung;Kim, Yong-Chan;Choi, Jong-Min;Ko, Jang-Myoun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3407-3412
    • /
    • 2007
  • The performance characteristics of the polymer electrolyte fuel cells (PEFCs) were investigated under various humidification conditions at steady-state and transient conditions. The PEFC studied in this study was characterized by I-V curves in potentiostatic mode. The I-V curves representing steady-state performance were obtained from OCV to 0.25V, and the dynamic performance responses were obtained at some points of voltages. The anodic external humidification was applied and the humidity was controlled from 20% to 100%. The effects of relative humidity of hydrogen were measured with the dry air at the cathode. At high voltage region, the performance at high temperature was higher, but at low voltage region, low temperature condition showed the higher performance. The dynamic responses were observed at the instant when the voltage of the PEFC was changed. It was observed that the performance reached steady-state earlier with the increase of temperature.

  • PDF

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

Humidification Optimization in Silicon-based Miniaturized Fuel Cell (실리콘으로 제작된 소형 연료 전지에서 가습 조건의 최적화)

  • Kwon, Oh-Joong;Won, Ho-Youn;Kim, Jae-Jeong
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2007
  • Single fuel cell was fabricated with a MEA (membrane electrode assembly) that had a $4cm^2$ active area and with silicon bipolar plates those were introduced to miniaturize the fuel cell by replacing heavy weight graphite plates. Optimum humidification condition for the single cell was selected based on performance results obtained varying humidifier temperature at a fixed feed rate of hydrogen and oxygen. Furthermore, to study the effect of humidification condition on the performance of a fuel cell stack, the fuel cell stack consisting of two MEAs and silicon bipolar plates was studied, then problems and characteristics of silicon-based fuel cell stack were examined.

Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply (고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

Prediction of Diesel Fuel Spray Characteristics in Compression Ignition Engine Cylinder by Intake Humidification (흡기 가습에 의한 압축 착화엔진 실린더 내 디젤 연료 분무 특성 예측)

  • Min, Se Hun;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.23 no.1
    • /
    • pp.30-35
    • /
    • 2018
  • The objective of this study is to predict numerically the effect of intake humidification on the injected diesel fuel spray characteristics in a compression ignition engine. In this work, Wave model and Ducowicz model were applied as the break-up model and evaporation model, respectively. The amount of water vapor for the humidification was changed from 0% to 30% of injected fuel mass. The number of applied meshes was generated from 49,000 to 110,000. At the same time, the results of this work were compared in terms of spray tip penetration, SMD and equivalence ratio distributions. It was found that the cylinder temperature and cylinder pressure were decreased with increasing water vapor mass by vaporization latent heat and specific heat, however, the difference was very small. So, the spray tip penetration was not different by water vapor mass. Also, higher equivalence ratio distributions were observed with increasing water vapor mass by the improvement of fuel atomization.

A Study on The Control of Humidification and Dew Condensation by On/Off Control (On/Off 제어에 의한 습도와 결로의 제어에 관한 연구)

  • Park, Dea-Heum;Kim, Du-Hee;Kim, Kyoung-Hoon;Jung, Young-Guan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.835-841
    • /
    • 2011
  • The humidification is essential for performance enhancement of the electrolysis of PEMFC because proton conductivity depends on hydration of the proton exchange membrane. In this study, the humidification experiment did about On/Off control the humidification and dew condensation for PEMFC by using of the membrane humidifiers. As the results, it was possible to approximation control of the humidity by using of the solenoid valve On/Off control on the membrane humidifier. Also the problem on the dew condensation was resolved by approximation humidity control through solenoid valve On/Off control and the removal of the dew condensation in the flow channel was verified through visualization experiment.

The Effects of Intra-operative Heated Humidification on Body Temperature, Blood Pressure and Shivering of Patients Undergoing General Anesthesia (수술 중 흡입가스의 가온가습이 체온, 혈압 및 떨림에 미치는 효과 -일반회로 적용군과의 후향적 비교연구-)

  • Bae, Ik Lyul;Hur, Myung Haeng
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.192-203
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the body temperature (BT), blood pressure (BP) and shivering in patients undergoing operation under general anesthesia between the heated humidification circuit tube (HHCT) group and the non-HHCT group. Methods: Data were extracted from the participants' medical records from September 1st to December 30th, 2009. The HHCT group consisted of 50 cases who were applied with heated and humidified gas via a specially designed circuit under general anesthesia. The HHCT which was adjusted at $41^{\circ}C$ was applied from induction of general anesthesia to extubation. In comparison, the non-HHCT group consisted of 50 cases who were applied with gas through standard breathing circuit without heat and humidification. Collected data were analyzed by $x^2$ test, t-test and repeated measures ANOVA. Results: The BT and shivering were significantly different between two groups (p<.001). But the BP was was not signigicantly different between the HHCT group and the non-HHCT group. Conclusion: The application of heated and humidified gases to patients under general anesthesia was effective in preserving the body temperature and reducing the shivering.

Effect of Humidification and Hardening Treatment on Seed Germination of Rice

  • Lee, Suk-Soon;Kim, Jae-Hyeun;Hong, Seung-Beom;Yun, Sang-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.3
    • /
    • pp.157-160
    • /
    • 1998
  • To find out the effects of humidification and hardening of rice (Oryza sativa L. cv. Ilpumbyeo) seeds on the germination, both normal and artificially aged seeds with 60% germination rate were humidified at 40, 60, and 80% RHs and $25^{\circ}C$ for five weeks or hydrated for 6, 12, 18, and 24 hours at $25^{\circ}C$ from one to five cycles for hardening. Relative humidity and duration of humidification did not affect the germination rate of normal seeds, while reduced the time to get 50% germination rate ($T_{50}$) by 1.0~1.6 days compared to that of normal seeds at $25^{\circ}C$. Aged seeds humidified at 40 and 60% RHs did not affect the germination rate and $T_{50}$ regardless of relative humidity and duration of treatment, while at 80% RH, the germination rate decreased and $T_{50}$ increased significantly with the duration of humidification. Hardening of normal seeds reduced $T_{50}$ by 0.7~1.1 days without changes in the germination rate. However, the germination rate and $T_{50}$ of aged seeds soaked in water for 6, 12, and 18 hours were similar regardless of soaking/drying cycles, while hardening of artificially aged seeds with 1~4 cycles in 24 hours soaking increased the germination rate by 11-16% and reduced $T_{50}$ by 1.4~2.0 days.

  • PDF