• 제목/요약/키워드: humidification

검색결과 140건 처리시간 0.03초

Home mechanical ventilation in children with chronic respiratory failure: a narrative review

  • Soyoung Kwak
    • Journal of Yeungnam Medical Science
    • /
    • 제40권2호
    • /
    • pp.123-135
    • /
    • 2023
  • Advances in perinatal and pediatric intensive care and recent advances in mechanical ventilation during the last two decades have resulted in an exponential increase in the number of children undergoing home mechanical ventilation (HMV) treatment. Although its efficacy in chronic respiratory failure is well established, HMV in children is more complex than that in adults, and there are more considerations. This review outlines clinical considerations for HMV in children. The goal of HMV in children is not only to correct alveolar hypoventilation but also to maximize development as much as possible. The modes of ventilation and ventilator settings, including ventilation masks, tubing, circuits, humidification, and ventilator parameters, should be tailored to the patient's individual characteristics. To ensure effective HMV, education for the parent and caregiver is important. HMV continues to change the scope of treatment for chronic respiratory failure in children in that it decreases respiratory morbidity and prolongs life spans. Further studies on this topic with larger scale and systemic approach are required to ensure the better outcomes in this population.

국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구 (A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea)

  • 김일겸;박우철
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.52-57
    • /
    • 2009
  • 본 논문은 실내 외의 온 습도변화에 따른 효율변동을 고려하여 폐열회수 환기장치의 성능을 예측할 수 있는 프로그램을 개발하였다. 국내의 외기조건에서 폐열회수 환기장치의 성능에 대한 기초자료를 얻기 위하여 고효율기자재 인증조건을 만족하는 풍량 $250m^3/h$의 일본 M사의 제품을 선정하였다. 폐열회수 환기장치를 설치할 경우 서울은 난방부하 69.1%, 냉방부하 59.4%의 절감효과가 나타났고, 부산은 난방부하 66.4%, 냉방부하 59.6%의 절감효과가 나타났다. 동절기의 가습부하는 강릉이 3월에 $0.737{\ell}/h$의 최대 가습부하가 발생하고, 하절기의 제습부하는 목포가 8월에 $1.008{\ell}/h$의 최대 제습부하가 발생한다. 동절기에 남부지방과 동해안지역은 배기측에 응축 또는 응결이 발생하지 않으나 그 외의 지역은 발생한다. 따라서 남부지방과 동해안지역을 제외한 지역에서는 동절기에 배기측에 응축 또는 응결이 발생하지 않도록 방지책을 강구하여야 한다.

기원별 용존 유기물의 분광특성 및 COD 산화율 비교 (Comparison of Spectroscopic Characteristics and Chemical Oxygen Demand Efficiencies for Dissolved Organic Matters from Diverse Sources)

  • 정가영;박민혜;허진;이승윤;신재기
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.589-596
    • /
    • 2009
  • The spectroscopic characteristics and chemical oxygen demand (COD) oxidation efficiencies were investigated for dissolved organic matters (DOM) from diverse sources, which may indirectly affect the concentrations and the quality of DOM found in watersheds. The DOM investigated for this study showed a wide range of the percent distributions of refractory organic matter (R-OM) from 8 to 100%. Relatively high R-OM distributions were observed for the DOM with the source of head water, sediments, paddy soils, field soils, and treated sewage whereas the DOM from livestock waste, reed, weeds, algae, and attached algae exhibited lower R-OM percent distributions. The percent distribution of R-OM had positive correlations with specific UV absorbance (SUVA) and humidification indices (HIX) of DOM. The investigated DOM was classified into four different source groups (i.e., biota, vegetables, soils, sediments) by comparing the synchronous fluorescence spectra. The DOM group from biota source was characterized by a prominent presence of protein-like fluorescence (PLF) whereas fulvic-like fluorescence (FLF) was additionally observed for vegetable-source DOM. FLF became significant for the DOM from both soils and sediments although no PLF was found for soil-derived DOM. A range of COD oxidation efficiency was observed for the various DOM, ranging from 36 to 94% and from 65 to 125% for $COD_{Mn}$ and $COD_{Cr}$, respectively. The results indicate that $COD_{Cr}$ reflects the higher OM concentration than $COD_{Mn}$. However, 95% confidence intervals of the COD oxidation efficiencies were similar for the two types of COD, suggesting that $COD_{Cr}$ may not be the superior OM index to $COD_{Mn}$ in terms of the variability of the oxidation efficiency. No significant correlations were obtained between COD oxidation efficiencies and the spectroscopic characteristics of DOM for this study.

고분자 전해질 연료전지용 막가습기의 상대습도 추정을 위한 소프트센서 개발 (Soft Sensor Development for Predicting the Relative Humidity of a Membrane Humidifier for PEM Fuel Cells)

  • 한인수;신현길
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.491-499
    • /
    • 2014
  • It is important to accurately measure and control the relative humidity of humidified gas entering a PEM (polymer electrolyte membrane) fuel cell stack because the level of humidification strongly affects the performance and durability of the stack. Humidity measurement devices can be used to directly measure the relative humidity, but they cost much to be equipped and occupy spaces in a fuel cell system. We present soft sensors for predicting the relative humidity without actual humidity measuring devices. By combining FIR (finite impulse response) model with PLS (partial least square) and SVM (support vector machine) regression models, DPLS (dynamic PLS) and DSVM (dynamic SVM) soft sensors were developed to correctly estimate the relative humidity of humidified gases exiting a planar-type membrane humidifier. The DSVM soft sensor showed a better prediction performance than the DPLS one because it is able to capture nonlinear correlations between the relative humidity and the input data of the soft sensors. Without actual humidity sensors, the soft sensors presented in this work can be used to monitor and control the humidity in operation of PEM fuel cell systems.

데이터센터용 멀티 외기이용 냉방시스템의 지역별 에너지 절감효과에 대한 연구 (A Study on the Regional Energy Conservation Effects of a Multi-stage Outdoor Air Enabled Cooling System in a Data Center)

  • 박문기;장현재
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.71-80
    • /
    • 2017
  • A Data center houses a large number of server computers, storage and etc in racks. With the rapid increase of heat generation rates per rack in a data center, energy consumption rates for cooling have been increased year by year. In this study, energy conservation effects of a MOA (multi-stage outdoor air enabled) cooling system in a data center has been investigated when it is applied to 5 different locations, Korea. As results, Energy conservation effects of the MOA cooling system was achieved at about 20% to 30%. Humidifier operation time was 40 to 55 days when supply air temperature was maintained at 13, and humidity condition was kept within the allowed range even though humidifier was off. Furthermore, humidification was not needed when supply air temperature was maintained at $25^{\circ}C$. In selected 5 locations in Korea, the difference of regional climatic conditions affected no more than 5% in cooling energy consumption rates.

Wire Mesh 적용을 통한 PEMFC 성능 향상에 관한 연구 (A Study on Performance Improvement of PEMFC Using Wire Mesh Cell Structure)

  • 진상문;백석민;허성일;양유창;김세훈
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.295-300
    • /
    • 2010
  • Metal bipolar plate applied to Polymer Electrolyte Membrane Fuel Cell is getting most attractive due to their good feasibility of mass production and low cost. But it is one of the immediate causes of performance decline because it is difficult to reduce channel pitch of metal bipolar plate. In this study, mesh was inserted in between bipolar plate and GDL to obtain uniform contact pressure without reducing channel pitch. The section measuring and performance test were carried out to confirm the mesh structure distributes contact pressure equally in reacting area. The performance of 3 type mesh structures developed in this study were higher than the normal cell at all over the current range. Especially, it showed that the mesh cell performance was increased and pressure drop was decreased with diminishing mesh gap size. The Mesh structure was more sensitive to humidification and contact pressure change than the normal cell.

황화수소 피독이 고분자전해질 막 연료전지의 성능에 미치는 영향 (The performance of PEMFC after hydrogen sulfide poisoning under various operating conditions)

  • 이수;진석환;김상명
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2011
  • Polymer electrolyte membrane fuel cell (PEMFC) performance degrades when hydrogen sulfide ($H_2S$) is present in the fuel hydrogen gas; this is referred to as $H_2S$ poisoning. This paper reveals $H_2S$ poisoning on PEMFC by measuring electrical performance of single cell FC under various operating conditions. The severity of $H_2S$ poisoning depended on $H_2S$ concentration under best operating conditions($65^{\circ}C$ of cell temperature and 100% of anode humidification). $H_2S$ adsorption occured on the surface of catalyst layer on MEA, but not on the gas diffusion layer(GDL) by analyzing SEM/EDX data. In addition, MEA poisoning by $H_2S$ was cumulative but reversible. After poisoning for less than 150 min, performance of PEMFC was recovered up to 80% by just inert nitrogen gas purging.

김원치과의원 실내디자인 (Kim-Won Dental Clinic Interior Design)

  • 최선희
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.99-100
    • /
    • 2006
  • The concept of dental clinic have been changed along the advanced dental science to meet the need of setting up high-technology-digital appliances. As the general idea about the dental clinic has been changed from systematic connection, the expansion of zoning needs to become more accurate and mote detailed. In the spacious waiting room. the interment cafe has been established to supply the information services, and the various multi-imaged channels, which were built in, will relieve the boredom of the waiting time. The formation of water space leads to the effect of humidification and makes parents share visual and auditory sympathy All of the unit-chairs attached cameras in the consultation room enables people to diagnose more quickly and precisely through the computerized system. Partitions have been set of to put it in and to help diagnosis process to be done smoothly in the formational space. The whole atmosphere is intended to be harmony with the natural surroundings in Je-Ju. It will inspire people visiting this clinic to image the deep blue sea in Je-Ju. By using projective non-material a lot, especially material wooden windows and doors, it is believed to create the bright and stable atmosphere. It will lead patients feel comfortable.

  • PDF

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

무수 전도성 양성자 교환막 제조 및 특성평가 (Preparation and characterization of proton exchange membranes in non-aqueous conduction)

  • 박진수;;백지숙;양태현;김창수;임성대;박구곤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.282-285
    • /
    • 2009
  • This study presents preparation and characterization of composite membranes based on ionic liquids. The ionic liquids act as water in sulfonated membranes. On the behalf of ionic conduction through ionic liquid inside the membranes, non-aqueous membranes showed Arrenhius dependence on temperature with no external humidification. It was implied that hopping mechanism of proton was dominant in the ionic liquid based membranes. In addition, small angle X-ray (SAXS) studies provided the information on morphology of ionic clusters formed by the interaction between sulfonic acid groups of the polymers and ionic liquids. The SAXS spectra showed matrix peaks, ionomer peaks and Prodo's law for Nafion based composite membranes and only matrix peaks for hydrocarbon based ones. However, ionic conductivity and atomic force microscopy (AFM) images showed the clear formation of ionic clusters of the hydrocarbon based composite membranes. It implies for ionic liquid based high temperature membranes that it is important to use sulfonated polymers as solid matrix of ionic liquid which can form clear ionic clusters in SAXS spectra.

  • PDF