CPLD-based Controller for Bi-directional Communication in a Capsule Endoscope (캡슐형 무선 내시경의 양방향 통신을 위한 CPLD 기반의 제어기 설계 및 구현)

  • Lee Jyung Hyun;Moon Yeon Kwan;Park Hee Joon;Won Chul Ho;Lee Seung Ha;Choi Hyun Chul;Cho Jin Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.447-453
    • /
    • 2004
  • In the case of a capsule that can acquire and transmit images from the intestines, the size of the module and the battery capacity in the capsule are subject to restriction. The capsule must be swallowable and the battery must maintain the stable power during the capsule travels in the gastrointestinal tract. Therefore, it is important to control the endoscope using bi-directional wireless communication. In this study, encoder and decoder CPLD modules for bi-directional capsule endoscopes were designed and implemented. The designed controller for capsule endoscope can transmit the images of GI-track from inside to outside of the body and the capsules can be controlled by external controller simultaneously. The designed and implemented controller was verified by an in-vivo animal experiments. From these experiments, it was verified that the CPLD module for bi-directional capsule endoscope satisfied the design specifications.

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Predicting Successful Conservative Surgery after Neoadjuvant Chemotherapy in Hormone Receptor-Positive, HER2-Negative Breast Cancer

  • Ko, Chang Seok;Kim, Kyu Min;Lee, Jong Won;Lee, Han Shin;Lee, Sae Byul;Sohn, Guiyun;Kim, Jisun;Kim, Hee Jeong;Chung, Il Yong;Ko, Beom Seok;Son, Byung Ho;Ahn, Seung Do;Kim, Sung-Bae;Kim, Hak Hee;Ahn, Sei Hyun
    • Journal of Breast Disease
    • /
    • v.6 no.2
    • /
    • pp.52-59
    • /
    • 2018
  • Purpose: This study aimed to determine whether clinicopathological factors are potentially associated with successful breast-conserving surgery (BCS) after neoadjuvant chemotherapy (NAC) and develop a nomogram for predicting successful BCS candidates, focusing on those who are diagnosed with hormone receptor (HR)-positive, human epidermal growth factor receptor 2 (HER2)-negative tumors during the pre-NAC period. Methods: The training cohort included 239 patients with an HR-positive, HER2-negative tumor (${\geq}3cm$), and all of these patients had received NAC. Patients were excluded if they met any of the following criteria: diffuse, suspicious, malignant microcalcification (extent >4 cm); multicentric or multifocal breast cancer; inflammatory breast cancer; distant metastases at the time of diagnosis; excisional biopsy prior to NAC; and bilateral breast cancer. Multivariate logistic regression analysis was conducted to evaluate the possible predictors of BCS eligibility after NAC, and the regression model was used to develop the predicting nomogram. This nomogram was built using the training cohort (n=239) and was later validated with an independent validation cohort (n=123). Results: Small tumor size (p<0.001) at initial diagnosis, long distance from the nipple (p=0.002), high body mass index (p=0.001), and weak positivity for progesterone receptor (p=0.037) were found to be four independent predictors of an increased probability of BCS after NAC; further, these variables were used as covariates in developing the nomogram. For the training and validation cohorts, the areas under the receiver operating characteristic curve were 0.833 and 0.786, respectively; these values demonstrate the potential predictive power of this nomogram. Conclusion: This study established a new nomogram to predict successful BCS in patients with HR-positive, HER2-negative breast cancer. Given that chemotherapy is an option with unreliable outcomes for this subtype, this nomogram may be used to select patients for NAC followed by successful BCS.

Nitric Oxide Delivery using Nanostructures and Its Biomedical Applications (나노 구조체를 이용한 산화질소 전달체에 대한 연구 및 바이오메디컬 응용)

  • Choi, Yunseo;Jeong, Hyejoong;Park, Kyungtae;Hong, Jinkee
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.305-312
    • /
    • 2019
  • The discovery of nitric oxide (NO) as a major signaling molecule in a number of pathophysiological processes - vasodilation, immune response, platelet aggregation, wound repair, and cancer biology - has led to the development of various exogeneous NO delivery systems. However, the development of ideal delivery system for human body application is still left as a challenge due to its high reactivity and short half-life in physiological condition. In this article, an overview of several nano-structures as potential NO delivery system will be presented, along with their recent research results and biomedical applications. Nano-size delivery system has immense advantages compared to others due to its high surface-to-volume ratio and capability for surface modification; thus, it has been proven to be effective in delivering nitric oxide with enhanced performance. Through this novel nano-structure delivery system, we are expecting to achieve sustained release of nitric oxide within adequate range of concentration, which ensures desired drug effects at the target site. Among different nano-structures, in particular, nanoparticle, microemulsion and nanofilm will be reviewed and compared to each other in respect of nitric oxide release profile. The proposed nano-structures for exogeneous NO delivery have a biological significance in that it can be further utilized in diverse biomedical fields as a highly promising therapeutic method.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.

Potential Exposure of Nanoparticles from Laboratory to Office (실험실에서 사무실로의 나노입자의 잠재적 노출)

  • Shin, Hyeokjin;Kim, Younghun
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • Nanoparticles are used in various fields such as chemistry, medicine, the environment, and information and communication. With the increasing use of engineered nanomaterials, exposure to nanoparticles is expected to increase in the workplace and the environmental media. However, while nanotechnology industries are expanding, research on the exposure assessment of nanomaterials to humans and the environment is only at a beginning stage. Especially, if nanoparticles with a size of 100 nm or less that are contained in nano-products are released unintentionally, they may pose potential risks to the human body through breathing or skin exposure. Therefore, in this work, the possibility of potential exposure of nanoparticles moving from the laboratory to the office was confirmed, and nanoparticle safety guidelines are proposed. A nano-collector was used to detect nanoparticles in the atmosphere, and through use of a scanning mobility particle sizer it was found that nanoparticle concentrations in the laboratory and the office tended to be similar. On the assumption that nanoparticles attached to a lab-coat move out of the laboratory, a lab-coat to which nanocarbon black was attached was shaken and the concentration of the remaining particles on the lab-coat determined. The results confirmed that sufficient amounts of nanoparticles attached to the lab-coat could move from the laboratory to the office along the path of a researcher; thus, safety guidelines for the handling of lab-coat nanoparticles are required.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

The Effect of Photoneutron Dose in High Energy Radiotherapy (10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향)

  • Park, Byoung Suk;Ahn, Jong Ho;Kwon, Dong Yeol;Seo, Jeong Min;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • Purpose: High-energy radiotherapy with 10 MV or higher develops photoneutron through photonuclear reaction. Photoneutron has higher radiation weighting factor than X-ray, thus low dose can greatly affect the human body. An accurate dosimetric calculation and consultation are needed. This study compared and analyzed the dose change of photoneutron in terms of space according to the size of photon beam energy and treatment methods. Materials and Methods: To measure the dose change of photoneutron by the size of photon beam energy, patients with the same therapy area were recruited and conventional plans with 10 MV and 15 MV were each made. To measure the difference between the two treatment methods, 10 MV conventional plan and 10 MV IMRT plan was made. A detector was placed at the point which was 100 cm away from the photon beam isocenter, which was placed in the center of $^3He$ proportional counter, and the photoneutron dose was measured. $^3He$ proportional counter was placed 50 cm longitudinally superior to and inferior to the couch with the central point as the standard to measure the dose change by position changes. A commercial program was used for dose change analysis. Results: The average integral dose by energy size was $220.27{\mu}Sv$ and $526.61{\mu}Sv$ in 10 MV and 15 MV conventional RT, respectively. The average dose increased 2.39 times in 15 MV conventional RT. The average photoneutron integral dose in conventional RT and IMRT with the same energy was $220.27{\mu}Sv$ and $308.27{\mu}Sv$ each; the dose in IMRT increased 1.40 times. The average photoneutron integral dose by measurement location resulted significantly higher in point 2 than 3 in conventional RT, 7.1% higher in 10 MV, and 3.0% higher in 15 MV. Conclusion: When high energy radiotherapy, it should consider energy selection, treatment method and patient position to reduce unnecessary dose by photoneutron. Also, the dose data of photoneutron needs to be systematized to find methods to apply computerization programs. This is considered to decrease secondary cancer probabilities and side effects due to radiation therapy and to minimize unnecessary dose for the patients.