• Title/Summary/Keyword: human blood

Search Result 2,338, Processing Time 0.031 seconds

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Quantitative Analysis of Prussic Acid by "Micro-Diffusion Analsis." II Determination of Prussic Acid in Human Blood (미량확산분석법에 의한 청산의 정량법 (제2보) 혈액중(CN-Met Hb)청산의 정량)

  • 심상혁;서정현
    • YAKHAK HOEJI
    • /
    • v.4 no.1
    • /
    • pp.47-49
    • /
    • 1959
  • Another application of the new quantitative analytical method of prussic acid by "Microdiffusion analysis" for the determination of prussic acid in human blood was studied. The blood containing potassium cyanide was dropped in outer room of unit, and then N-sulfuric acid was added. The liberated HCN gas was absorbed into nickel sulfate solution of inner room, afterward, absorbed prussic acid was determined with EDTA by residual titration. The result was coincided with the result of Liebig Denigs' method at ordinary temperature.

  • PDF

The Development of Risk Predictive Model for Air-borne Lead in Blood (대기 중 납의 RISK예측모형 개발)

  • 김종석
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.46-51
    • /
    • 1993
  • In order to survery the risk of air-borne lead to human, the relation between air-borne lead level and blood lead level was examined by using of the kinetic model and statistical model. The results of this survey were as follows: 1. The pathways of lead intake were food and water, mainly. 2. Though blood lead level of Korean urbanire was higher than that of American or Japanese, it was not so severe as to influence human health. 3. The lead content in food and water was high, and so it is needed to confirm the cause of high content was whether second contamination by air pollution or not.

  • PDF

Malaria transmission potential by Anopheles sinensis in the Republic of Korea

  • Lee, Hee-Il;Lee, Jong-Soo;Shin, E-Hyun;Lee, Won-Ja;Kim, Yoon-Young;Lee, Kyung-Ro
    • Parasites, Hosts and Diseases
    • /
    • v.39 no.2
    • /
    • pp.185-192
    • /
    • 2001
  • To evaluate the factors that determine the transmission level of vivax malaria using vectorial capacity, entomological surveys were conducted from .lune to August, 2000. From 6 nights of human-bait collection in Paju, the human biting rate (ma) was counted as 87.5 bites/man/night. The parity of Anopheles sinensis from human baiting collections fluctuated from 41% to 71% (average 48.8%) of which the rate gradually increased as time passed on: 35.2% in Jun. ; 55.0% in July; 66.2% in Aug. From this proportion of parous, we could estimate the probability of daily survival rate of An. sinensis to be 0.79 assumed with 3 days gonotrophic cycle and the expectancy of infective life through 11 days could be defined as 0.073. Blood meal analysis was performed using ELISA to determine the blood meal source. Only 0.8% of blood meals were from human hosts. We could conclude that An. sinensis is highly zoophilic (cow 61.8%) Malaria is highly unstable (stability index < 0.5) in this area. From these data, vectorial capacity VC) was determined to be 0.081. In spite of a high human biting rate (ma), malaria transmission potential is very low due to a low human blood index. Therefore, we could conclude that malaria transmission by An. sinensis is resulted by high population density, not by high transmission potential. For this reason, we need more effort to decrease vector population and vector-human contact to eradicate malaria in Korea.

  • PDF

Quantitative Determination of Lipid Hydroperoxide in Human Blood Serum by Ferrothiocyanate Method (Ferrothiocyanate법에 의한 혈청 Lipid Hydroperoxide정량)

  • Paik, Taik-Hong;Park, Chan-Sik;Chun, Hyun-Ja
    • Journal of the Korean Applied Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.25-30
    • /
    • 1988
  • In order to develope the method of quantitative determination of lipid hydroperoxide in human blood serum, we tried the ferrothiocyanate method to total lipids extracted by Bligh-Dyer method and obtained the results as follows. 1. The maximum absorbance showed at the concentration of Mohr's solution, 0.127M at pH 1.70 and ammonium thiocyanate solution, 3.95M in the ferrothiocyanate method. 2. When hydrogen peroxide, cumene hydroperoxide, and oxidized linoleic acid were added to serum, and extracted them by Bligh-Dyer method to examine the extraction efficiency, we confirmed that cumene hydroperoxide and oxidized linoleic acid were extracted in $CHCI_3$ phase, and hydrogen peroxide in $MeOH-H_2O$ phase, respectively. 3. The concentration of lipid hydroperoxide of total lipids extracted from normal adult serum was $2.0{\times}10^{-5}M$, and increased proportionally the concentration of lipid hydroperoxide by increasing the amount of serum. 4. When we compared the total lipids extracted by Bligh-Dyer method and total lipids extracted after lipoprotein is precipitated by Yagi method in human blood serum, the concentration of lipid hydroperoxide was showed nearly the same value. From our results, we concluded that the concentration of lipid hydroperoxide in human blood serum could be determined quantitatively by ferrothiocyanate method.

Fermented Kochujang Supplement Shows Anti-obesity Effects by Controlling Lipid Metabolism in C57BL/6J Mice Fed High Fat Diet

  • Koo, Bon-Sun;Seong, So-Hui;Kown, Dae-Young;Sohn, Hee-Sook;Cha, Youn-Soo
    • Food Science and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.336-342
    • /
    • 2008
  • The aim of the present study was to assess the anti-obesity effects of fermented kochujang supplement in C57BL/6J mice. Thirty mice were divided into 3 groups; normal diet control group (ND), high fat diet control group (HD), and high fat diet plus kochujang supplemented group (HDK). Results were as follows: 1. Fennented kochujang supplement in high fat diet decreased body weight and epidydimal and back fat weight compared to non-supplement in HD group. 2. Lipid content and blood glucose level were lower in HDK group than HD group. 3. Fermented kochujang supplement increased mRNA level of lipolytic genes such as acyl-CoA synthetase (ACS), carnitine palmitoyltransferase-1 (CPT-1), and uncoupling proteins-1 (UCP-1) expression, whereas decreased mRNA level of adipogenic genes such as acetyl CoA carboxylase (ACC) expression. These findings suggest that fermented kochujang supplement in high fat diet normalized body weight, epididymal and back fat weight, lipid content, and blood glucose levels through controlling lipid metabolism and provides basic information on the control of obesity.

Development of Blood Pressure Simulator for Test of the Arm-type Automatic Blood Pressure Monitor (팔뚝형 자동혈압계 평가용 혈압 시뮬레이터 개발)

  • Kim, S.H.;Yun, S.U.;Cho, M.H.;Lee, S.J.;Lim, M.H.;Seo, S.Y.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.239-246
    • /
    • 2015
  • Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk motor. Then, using the silicon tube, it implements the situations such as human blood vessels, and to output the generated pressure waveform. Simply the BPS's phantom put on the cuff and it is able to simulate blood pressure. So anyone can quickly test the blood pressure monitor within one minute and it is possible to shorten the test time required for the automatic blood pressure monitor. In Performance test, the trends and the standard deviation of the values measured in the BPS is similar to the value of the measured pressure from people with normal blood pressure. Thus, the development BPS showed a possibility of taking into account the actual blood pressure measurement environment simulator.

Blood Analysis for Indirect Doping Control of Erythropoietin in Sports (운동선수들의 혈액분석을 통한 Etrythropoietin 간접도핑검사)

  • 이정란;김소영;홍지연;김명수;최명자
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.422-431
    • /
    • 2003
  • The use of recombinant human erythropoietin (rhEPO), a stimulator of erythropoiesis, banned in sports because of the medical risk associated with thrombosis. Due to analytical difficulties to differentiate between natural human EPO (hEPO) and rhEPO, blood parameters of erythropoiesis such as contents of hemoglobin (cut-off value <17.5 g/d l for man, and < 16.0 g/dl for women), hematocrit and reticulocytes (cut-off value <2.0%) were measured to focus the misuse of rhEPO. We conducted anti-doping test for 122 blood samples of the World Cup athletes. The mean values of key parameters are as follows; 14.5$\pm$1.0 g/dl for hemoglobin, 41.7$\pm$2.8% for hematocrit, and 1.3$\pm$0.4% for reticulocyte. Blood sample was found to be stable up to 8 hours for the reticulocyte measurement. In addition, the soluble transferrin receptor and ferritin levels were measured by immunoassay methods using plasma samples (n=28) in which the mean value was 0.8$\pm$0.5 $\mu\textrm{g}$/$m\ell$ and 54.6$\pm$33.7 ng/$m\ell$, respectively. The results indicate that all samples tested were negative for the blood parameters of indirect anti-doping test for hEPO misuse. The statistical evaluation suggest that several other parameters such as red blood cell, mean corpuscular hemoglobin concentration, mean corpuscular volume, mean corpuscular hemoglobin and white blood cell could be considered as factors influencing hEPO function in addition to five parameters mentioned.

Differentiation of Osteoblast Progenitor Cells from Human Umbilical Cord Blood (제대혈액에서 골조직 특이세포로의 분화)

  • Hong, Seung-Jin;Lee, Eun-A;Chae, Gue-Tae;Han, Hoon
    • IMMUNE NETWORK
    • /
    • v.2 no.3
    • /
    • pp.166-174
    • /
    • 2002
  • Background: Human umbilical cord bloods, which could be taken during the delivery are utilized as a source of hematopoietic stem cells. Also in cord blood, there are several kinds of stem cells such as endothelial and mesenchymal stem cells. Methods: We isolated the mesenchymal stem cells from human umbilical cord bloods and confirmed the differentiation of these cells into osteoblast progenitor cells. The mesenchymal stem cells derived from umbilical cord blood have the ability to differentiate into specific tissue cells, which is one of characteristics of stem cells. These cells were originated from the multipolar shaped cells out of adherent cells of the umbilical cord blood mononuclear cell culture. Results: The mesenchymal stem cells expressed cell surface antigen CD13, CD90, CD102, CD105, ${\alpha}$-smooth muscle actin and cytoplasmic antigen vimentine. Having cultrued these cells in bone formation media, we observed the formation of extracellular matrix and the expression of alkaline phosphatase and of mRNA of cbfa-1, ostoecalcin and type I collagen. Conclusion: From these results we concluded that the cells isolated from the umbilical cord blood were mesenchymal stem cells, which we could differentiate into osteoblast when cultured in bone formation media. In short, it is suggested that these cells could be used as a new source of stem cells, which has the probability to alternate the embryonic stem cells.

Increased Sister Chromatid Exchange in Peripheral Blood Lymphocytes from Humans Exposed to Pesticide: Evidence Based on a Meta-analysis

  • Yang, Hai-Yan;Liu, Jing;Yang, Si-Yu;Wang, Hai-Yu;Wang, Ya-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9725-9730
    • /
    • 2014
  • Background: Sister chromatid exchange (SCE) in human peripheral blood lymphocytes is one of the most extensively studied biomarkers employed to evaluate genetic damage subsequent to pesticide exposure. Objective: To estimate the pooled levels of SCE in human peripheral blood lymphocytes among population exposed to pesticide. Materials and Methods: Meta-analysis on the association between SCE frequency and pesticide exposure was performed with STATA 10.0 software package and Review Manager 5.0.24 in this study. Results: The overall means of SCE were 7.88 [95% confidence intervals (95%CI): 6.71-9.04] for exposure group and 6.05 (95%CI: 5.13-6.95) for controls, respectively. There was statistically significant difference in the SCE frequency in human peripheral blood lymphocytes between pesticide-exposed groups and control groups, and the summary estimate of weighted mean difference was 1.69 (95%CI: 1.01-2.38). We also observed that pesticide-exposed population had significantly higher SCE frequency than control groups among smokers, nonsmokers, pesticide applicator, pesticide producer, other exposure population and Asian population in stratified analyses. Conclusions: Data indicate that the SCE frequency in human peripheral blood lymphocytes might be an indicator of early genetic esffects for pesticide-exposed populations.