• Title/Summary/Keyword: human blood

Search Result 2,382, Processing Time 0.038 seconds

Antioxidant and Anti-Inflammatory Effects of Kamisipjeondaebotang in RAW 264.7 Cells (가미십전대보탕의 RAW 264.7 세포에서 항산화 및 항염증 효과)

  • Myung, Jeong-Ho;Lee, Myung-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.11
    • /
    • pp.1271-1277
    • /
    • 2017
  • As Kamisipjeondaebotang (KSD) extract is an herbal ingredient, safety is very important due to possible cell poisoning or heavy metal toxicity to organs when administered to humans or animals. Accordingly, this study examined the antioxidant and anti-inflammatory effects of KSD extract to confirm its medicinal safety by using RAW 264.7 cells after heavy metal screening, functional index test of the liver and kidney, and cell survival rate test. Heavy metals were not found in KSD extracts or were less than standard amounts. Liver function indices such as aspartate aminotransferase and alanine aminotransferase revealed low values and kidney function indices such as creatinine and blood urea nitrogen were not significantly different from the normal group. This proved the safety to the human. RAW 264.7 cells showed no poisoning compared to the control group in terms of survival rate. Regarding the antioxidant effect of KSD extract, 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and 2,2'-azino-bis(3-ethylbenzothiazo-line-6-sulphonic acid) radical scavenging activity increased at concentrations over $10{\mu}g/mL$. The anti-inflammatory effect of KSD extract significantly decreased based on the amount of nitric oxide at concentrations of 10 and $100{\mu}g/mL$ compared to the control group. Expression of interleukin (IL)-$1{\beta}$ and IL-6 decreased in a concentration-dependent manner. There was no significant difference in tumor necrosis factor-${\alpha}$ level. Based on the results, KSD can be regarded as a safe antioxidant with anti-inflammatory effects for fracture treatment.

Study on Relationship between Meridian Muscles and Modern Manual Therapy centered on Positional Release Therapy and Muscle Energy Techniques (자세이완기법과 근에너지기법을 중심으로 한 경근(經筋)과 현대 도수치료술의 상관성 연구)

  • Cha, Sang Ju;Im, Chae-Gwang;Kim, Kwang Joong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.630-640
    • /
    • 2012
  • Recently, the range of meridian muscle has expanded to muscular membranes, tendons and sinews as well as muscles, comprehending the modern manual therapy and its theories. So, in this study, the movement of body is explained through the assignment of meridian muscles into 3 Yins and 3 Yangs, and the modern manual therapy is understood with body's movement principles rather than with simple muscular movements. For this, the ground that the meridian muscles can expand to muscular membranes, tendons and sinews is researched in newest papers and studies rather than in the conventional studies that have analyzed the meridian muscles just in anatomic viewpoints. And, to find out how it can be applied to the actual clinic, its relationship with modern manual therapies such as Positional Release Therapy and Muscle Energy Techniques which are in the spotlight lately is also researched, getting the following results: Modern manual therapy is to keep the mutual balance of Yin-Yang meridian muscles after all and secure the stability of body to relieve the pains due to the stagnation of energy and blood. In the main body, they can be allotted into the opening of Great Yang/Great Yin, the closing of Bright Yang(陽明)/Small Yin, and the pivoting of Small Yang/Growing Yin (厥陰). The bending and stretching of meridian muscles as well as the movement of body can be explained according to the principle of opening, closing and pivoting. When the body is divided into 3 Yins and 3 Yangs, the viewpoint of Yin-Yang-Inside-Outside can be applied to the protagonist and antagonist muscles, giving a theoretic basis to the modern manual therapy. In the process to understand Positional Release Therapy and Muscle Energy Techniques in the viewpoint of Meridian Muscle, it turned out that the meridian muscle theory of Oriental Medicine which used to be known only in documents can well explain the movement mechanism of human body. The stress reaction through the reciprocal inhibition in Positional Release Therapy and Muscle Energy Techniques can also be understood with Yin-Yang-Inside-Outside.

MRI of Hydrosyringomyelia Combined to Hydrocephalus and Occipital Dysplasia in a Dog (개에서 뇌수두증과 후두골 이형성증을 동반한 척수공동증의 자기공명영상학적 평가 1례)

  • Choi Chi-Bong;Bae Chun-Sik;Kim Hwi-Yool
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.664-667
    • /
    • 2005
  • Hydrosyringomyelia is a dilation of the spinal cord central canal. In human it may be caused by congenital malformations such as Dandy-Walker syndrome and Chiari malformations or may be acquired as a result of infection, trauma or neoplasia. Hydrocephalus is an excessive accumulation of cerebrospinal fluid within the ventricles and occipital dysplasia is the dorsal extension of the foramen magnum. Hydrosyringomyelia and hydrocephalus can be confirmed by computed tomography or magnetic resonance imaging (MRI). A 3-year-old male maltese was presented with a history of long-term seizure. Blood examination was all unremarkable. On rostrodorsal-caudoventral oblique radiograph of the skull showed severe occipital dysplasia. On brain sonography through the persistent fontanelle, severe lateral ventriculomegaly was revealed. MRI examination revealed hydrocephalus and hydrosyringomyelia. Diuretic therapy didn't reduce clinical symptoms and surgical decompression was conducted. The dog responded well with ventriculo-peritoneal shunting. MRI is the most superior modality to diagnose hydrocephalus and hydrosyringomyelia, to plan therapy and to determine the prognosis.

Intelligent Diagnosis Assistant System of Capsule Endoscopy Video Through Analysis of Video Frames (영상 프레임 분석을 통한 대용량 캡슐내시경 영상의 지능형 판독보조 시스템)

  • Lee, H.G.;Choi, H.K.;Lee, D.H.;Lee, S.C.
    • Journal of Intelligence and Information Systems
    • /
    • v.15 no.2
    • /
    • pp.33-48
    • /
    • 2009
  • Capsule endoscopy is one of the most remarkable inventions in last ten years. Causing less pain for patients, diagnosis for entire digestive system has been considered as a most convenience method over a normal endoscope. However, it is known that the diagnosis process typically requires very long inspection time for clinical experts because of considerably many duplicate images of same areas in human digestive system due to uncontrollable movement of a capsule endoscope. In this paper, we propose a method for clinical diagnosticians to get highly valuable information from capsule-endoscopy video. Our software system consists of three global maps, such as movement map, characteristic map, and brightness map, in temporal domain for entire sequence of the input video. The movement map can be used for effectively removing duplicated adjacent images. The characteristic and brightness maps provide frame content analyses that can be quickly used for segmenting regions or locating some features(such as blood) in the stream. Our experiments show the results of four patients having different health conditions. The result maps clearly capture the movements and characteristics from the image frames. Our method may help the diagnosticians quickly search the locations of lesion, bleeding, or some other interesting areas.

  • PDF

Thermal Insulation Effect of Inflatable Life Vest on the Drowned Individual estimated by Numerical Analysis (익수자 체온 저하에 미치는 팽창식 구명동의의 단열효과 수치 분석)

  • Kim, Sung Chan;Lee, Kyung Hoon;Hwang, Se Yun;Lee, Jin Sung;Lee, Jang Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.285-291
    • /
    • 2015
  • Exposure to cold sea water can be life-threatening to the drowned individual. Although appropriate life jacket can be usually be provided for the buoyance at the drowning accident, heat loss can make the drowned individual experience the hypothermia. Inflatable life jackets filled with inflatable air pocket can increase the thermal protection as well as the buoyancy force. Because it is important to know how the human body behaves unde the different life jacket, present study compares the thermal insulation capacity of solid type life jacket with that of inflatable life jacket. In order to represent the insulation capacity of life jacket, thermal resistance is estimated based on the assumption of steady-state. Also, a transient three-dimensional thermal distribution of the thigh is analyzed by using finite element method implementing the Pennes bioheat equation. The finite element model is a segmental, multi-layered representation of the body section which considers the heat conduction within tissue, bone, fat and local blood flow rate.

Bioequivalence of Tagamet Tablet to Sinil CIMETIDINE Tablet (cimetidine 400 mg) (타가메트정 400 mg에 대한 신일시메티딘정 400 mg의 생물학적동등성시험)

  • Yoon, Mi-Kyeong;Lee, Byoung-Moo;Lee, Sung-Jae;Kim, Sun-Kyu;Lee, Jae-Hwi;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.521-527
    • /
    • 2004
  • Cimetidine is a histamine $H_2-receptor$ antagonist, used for the treatment of endoscopically or radiographically comfirmed duodenal ulcer, pathologic GI hypersecretory conditions, and active, benign and gastric ulcer. Simple method for determining cimetidine in human plasma has been developed and validated. The analytical procedure for cimetidine showed a linear relationship in the concentration ranges from $0.05\;to\;5\;{\mu}g/ml$. Coefficient of variance (CV, %) for intraday and interday validation and relative error (RE, %) were less than ${\pm}15%$. Based on this analytical method, the bioequivalence of two cimetidine 400 mg tablets, reference (Tagamet 400 mg) and test drug (Sinil CIMETIDINE 400 mg) was evaluated according to the guidelines set by the Korea Food and Drug Administration (KFDA). Release of cimetidine from the tablets in vitro was tested using KP VIII Apparatus II with various dissolution media (pH 1.2, 4.0, 6.8 buffer solutions and water). Twenty-four healthy volunteers, $21.38{\pm}1.86$ years in age and $68.71{\pm}8.68\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was performed. After oral administration of a tablet containing 400 mg of cimetidine, blood samples were taken at predetermined time intervals and concentrations of cimetidine in plasma were determined using HPLC equipped with UV detector. The dissolution profiles of the two tablet formulations were very similar at all dissolution media. In addition, pharmacokinetic parameters such as $AUC_t$ and $C_{max}$ were calculated and ANOVA was employed for the statistical analysis of parameters. The results were revealed that the differences in $AUC_t$ and $C_{max}$ between the two tablets were 4.17 % and 0.97% respectively. At 90% confidence intervals, the differences in these parameters were also within ${\pm}20%$. All of the above mentioned parameters have met the criteria of KFDA guidelines for bioequivalence, indicating that the test drug tablet (Sinil CIMETIDINE tablet) is bioequivalent to Tagamet 400 mg tablet.

Screening of $\alpha$-Amylase and $\alpha$-Glucosidase Inhibitor from Nepalese Plant Extracts (100종 네팔 식물 추출물로부터 $\alpha$-Amylase 및 $\alpha$-Glucosidase저해제의 선별)

  • Kim, Mi-Sun;Ahn, Seon-Mi;Jung, In-Chang;Kwon, Gi-Seok;Sohn, Ho-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.2
    • /
    • pp.183-189
    • /
    • 2010
  • In the course of screening for anti-acidosis and anti-diabetes agent from natural products, the inhibitory activities of Nepales plant extracts against microbial $\alpha$-amylase and $\alpha$-glucosidase were evaluated. Among the 100 different kinds of ethanol extracts, Cedrus deodara (Roxb.) G. Don and Myrica nagi Thunb showed strong inhibition activities against $\alpha$-amylase. The $IC_{50}$ values of C. deodara (Roxb.) G. Don, M. nagi Thunb and acarose, a commercial available anti-diabetes agent, were 44.5, 47.5 and $50.5\;{\mu}g/mL$, respectively. Considering the crude extract of C. deodara (Roxb.) G. Don, and M. nagi Thunb, these extracts have strong potentials as anti-acidosis or anti-diabates agent. In a while, Cleistocalyx operculatus (Roxb.) extract showed a good inhibition activity to $\alpha$-amylase and $\alpha$-glucosidase, even it was recently reported. The selected three extracts did not show any hemolysis activity against human red blood cell up to 1 mg/mL, and the inhibition activities were maintained by heat or acid treatment. Moreover, treatment of HCl (0.01N) for 1 h into C. operculatus (Roxb.) and M. nagi Thunb increased the inhibition activity from 50% to 70%. Our results suggest that C. deodara (Roxb.) G. Don, M. nagi Thunb, and C. operculatus (Roxb.) are potential as anti-acidosis and anti-diabetes agents.

Molecular Analysis of Growth Factor and Clock Gene Expression in the Livers of Rats with Streptozotocin-Induced Diabetes

  • Kim, Joo-Heon;Shim, Cheol-Soo;Won, Jin-Young;Park, Young-Ji;Park, Soo-Kyoung;Kang, Jae-Seon;Hong, Yong-Geun
    • Reproductive and Developmental Biology
    • /
    • v.33 no.3
    • /
    • pp.163-169
    • /
    • 2009
  • Many biological systems are regulated by an intricate set of feedback loops that oscillate with a circadian rhythm of roughly 24 h. This circadian clock mediates an increase in body temperature, heart rate, blood pressure, and cortisol secretion early in the day. Recent studies have shown changes in the amplitude of the circadian clock in the hearts and livers of streptozotocin (STZ)-treated rats. It is therefore important to examine the relationships between circadian clock genes and growth factors and their effects on diabetic phenomena in animal models as well as in human patients. In this study, we sought to determine whether diurnal variation in organ development and the regulation of metabolism, including growth and development during the juvenile period in rats, exists as a mechanism for anticipating and responding to the environment. Also, we examined the relationship between changes in growth factor expression in the liver and clock-controlled protein synthesis and turnover, which are important in cellular growth. Specifically, we assessed the expression patterns of several clock genes, including Per1, Per2, Clock, Bmal1, Cry1 and Cry2 and growth factors such as insulin-like growth factor (IGF)-1 and -2 and transforming growth factor (TGF)-${\beta}1$ in rats with STZ-induced diabetes. Growth factor and clock gene expression in the liver at 1 week post-induction was clearly increased compared to the level in control rats. In contrast, the expression patterns of the genes were similar to those observed after 5 weeks in the STZ-treated rats. The increase in gene expression is likely a compensatory change in response to the obstruction of insulin function during the initial phase of induction. However, as the period of induction was extended, the expression of the compensatory genes decreased to the control level. This is likely the result of decreased insulin secretion due to the destruction of beta cells in the pancreas by STZ.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.