• 제목/요약/키워드: household combustion

검색결과 26건 처리시간 0.021초

低質炭의 利用硏究 (第二報) (家庭用煉炭의 燃燒速度의 調節) (Studies on the Utilization of Low Quality Goals(2) Regulation of combustion velocity on household briquettes)

  • 오신섭;김정혁
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.81-82
    • /
    • 1957
  • With the purpose of applying the results outlined in Report(1) to household briquetts, combustion ratio, i, c, combustion hours has been determined. The results of combstion velocity are directly proportional to rate of mixture of anthracite, and inversely proportional to graphitc.

생활용품(냉장고·세탁기·장롱·소파)의 화재성장 특성 연구 (A Study on the Flame Growth Characteristics of Household Items(Refrigerator·Washing machine·Drawer·Sofa))

  • 박영주
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.45-51
    • /
    • 2015
  • This study was full-scale combustion test for flame growth characteristics and temperature characteristics analysis to predict the risk of household Items fire when fire occurs. Experimental results, Refrigerator flames were the highest measured in 15 min time, and Washing machine is between 20 ~ 30 min, Drawer is 5 min, Sofa was enabled up to the size of the flame 15 min. In addition, the maximum combustion temperature was found from the time 20 min ~ 25 min, Sofa is temperature was elevated up to $1190^{\circ}C$, Refrigerator is $1,162^{\circ}C$, Drawer is $822^{\circ}C$, Washing machine appeared to be rising up to $670^{\circ}C$. Therefore, in the case of the maximum temperature of combustion Sofa it showed relatively high.

1kW급 가스엔진 열병합발전시스템 성능특성에 관한 연구 (The Operation Characteristics of Domestic 1kW Gas Fueled Internal Combustion Engine Cogeneration System)

  • 최재준;박병식;정대헌;임용훈;최영호;송대섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.321-324
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and recently, the household cogeneration system has been the center object of attention because of the loss of power transmission and the reasonable energy consumption relative to the household (condensing) boiler producing heat only. A tiny, 1kW of electrical output, gas fueled internal combustion engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. With the emission characteristics, the cogeneration system was analyzed. It was showed the gas engine cogeneration system produced the lowest NOx level compared any other cogeneration system due to the three-way catalyst.

  • PDF

평판형 예혼합 버너의 다양한 화염면 매질 및 열교환기에 따른 연소 특성 (A Study on the Combustion Characteristics of Flat-Plate Premixed Burner for Various Flame Surface Media and Heat Exchangers)

  • 조은성;박창권;최경석
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1033-1040
    • /
    • 2011
  • 예혼합 버너는 높은 효율과 낮은 배기 때문에 가정용 보일러 버너 시스템에 매우 강력한 버너이다. 일반적으로 가정용 보일러 버너는 내부에 농후한 예혼합 불꽃으로 구성하고 연료는 2차공기의 공급에 의하여 완전연소 되는 분젠 버너를 이용한다. 이것은 상대적으로 긴 불꽃 길이와 높은 과잉공기비에서 작동하기 때문에 높은 효율을 갖는 소형 보일러에 적용하기 어렵다. 이 논문에서 메탈 화이버, 세라믹, SUS 핀과 같은 매질을 사용하는 예혼합 연소 버너의 특징을 실험하였다. 특히, 표면 매질의 비반응 유동 특성은 버너 표면 전체의 유동 속도를 측정하고 조정하였다. 연소 실험은 화염 사진과 화염 온도 측정에 의하여 수행되었다. CO와 NO는 다양한 과잉 공기비와 열량값에 대하여 버너 표면 매질, 연소실, 열교환기의 특성을 측정하고 평가하였다.

소각로의 연소 공기 유동 해석 (Analysis of Combustion Air Flow in Incinerator)

  • 이동혁
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.

몽골 울란바토르 시 전통 주거공간의 실내공기 오염 기초조사 (Indoor air pollution in ger, a traditional type of residence in Mongolia)

  • 이보람;;;이기영
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.118-125
    • /
    • 2016
  • Objectives: The traditional type of residence in used in Mongolia, called a ger, is an important residential form and applies coal combustion for cooking and heating. The combustion of coal in ger is the major source of indoor air pollution. The purposes of this study were to measure indoor air pollution in ger and determine the effect of cooking and heating activities. Methods: Indoor temperature, relative humidity, particulate matter less than $2.5{\mu}m$ ($PM_{2.5}$) and black carbon (BC) were continuously measured for 24 hours in eight ger. The measurements were conducted in January or February 2015. Heavy metals in $PM_{2.5}$ filter samples were analyzed by ICP-MS. Results: Average indoor temperature and relative humidity were $19.6{\pm}4.6^{\circ}C$ and $21.4{\pm}5.2%$, respectively. The average indoor $PM_{2.5}$ concentration in the eight ger was $119.8{\mu}g/m^3$ and ranged from 69.4 to $202.7{\mu}g/m^3$. The peak concentrations of $PM_{2.5}$ and BC during cooking and heating periods were several times higher than the 24- hour average concentration. Conclusion: The major contributor to indoor $PM_{2.5}$ and BC concentrations in the ger was coal combustion for cooking and heating.

가정용 가스 냉난방기용 연소기의 성능개선 연구 (Enhancement of Burner Performance of Household Gas Fired Absorption Chiller/Heaters)

  • 윤영석;유현석;김태환;이중성;한정옥
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.111-115
    • /
    • 1999
  • In order to enhance the burner performance of household gas fired absorption chiller/heaters, the operating condition(excess air $\approx$ 10%) of the burner currently being used was required to be optimized. In this regard, we examined where the $CO_{\min}$. emission limit was located between blow off and yellow tip limit and how much amount of excess air was exhausted by means of observing blow off and yellow tip limit. It was found that the $CO_{\min}$ limit(excess air ${\approx}$ 4%) was determined near the yellow tip limit. The effect of exhaust pressure on the $CO_{\min}$. limit was that, if exhaust pressure was higher than that in steady condition, higher air blower fan rpm is demanded to maintain the $CO_{\min}$ limit. Therefore, it was necessary to optimize the operating condition of burner in terms of a thermal efficiency and safety.

  • PDF

분포판 및 염공변화에 따른 원통형 예혼합 버너의 연소 특성 (Combustion Characteristics of Cylindrical Premixed Burner using Different Baffle Plate and Flame Holes)

  • 이필형;황상순
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.350-359
    • /
    • 2017
  • Premixed burner is a very strong candidate in household condensing gas boiler burner system because it has low CO and NOx emission with high thermal efficiency. The objective of this study was to determine combustion characteristics of cylindrical premixed burner using different baffle plate and flame holes. Results showed that cylindrical premixed flame mode could be changed into lift-off flame, blue flame, red flame, and green flame with increasing equivalence ratio. In particular, blue flame was found to be very stable at heating load of 8,82~35,280 kcal/h. NOx emission was under 26 ppm between 0.775 to 0.813 of equivalence ratio. CO emission was under 58 ppm under the same equivalence ratio. Thermal efficiency, a very important index in condensing gas boiler, was found to be above 90.13% under the same equivalence region.

Microwave를 이용한 배지 융해와 공기 제거 (Usefulness of microwave to melt rehydrated media and to remove oxygen from anaerobic tube media)

  • 정윤섭;이귀녕;이삼열
    • 미생물학회지
    • /
    • 제18권3호
    • /
    • pp.148-152
    • /
    • 1980
  • The microwave of 2450 MHz, generated by a household cooking oven, was evaluated for its applicability to melt various rehydrated media and to remove dissolved oxygen from tubed media for anaerobic culture. The effect on the sterilization of E. coli in selective media was also evaluated. The following results were obtained. 10 The microwave oven was useful in saving time for melting media and in eliminating heat and combustion gas from the laboratory, which were inevitable by-products in the conventional flame method. 2) Dissolved oxygen could be removed without boiling over by exposing the tubes of anaerobic culture medium after putting them in a wire basket in a beaker with water. 30 The count of E. coli during the melting of MacConkey and EMB agar were similar to those treated with open flame. The microwave treatment was not considered a possible mean to replace autoclaving even in these selective media.

  • PDF

Autoignition of Urethane Foam to be Used as the Insulator of the Household Refrigerator

  • Choi, Jae Wook;Mok, Yun Soo
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.47-51
    • /
    • 2002
  • This study was performed by measuring the minimum ignition temperature of polyurethane form recovered from the recycling process of the end-of-life home appliances. The critical ignition temperature of polyurethane form was lower as the size of the sample vessel was increased, and that of polyurethane form using cyclopentane as the forming agent was relatively lower than the polyurethane form using CFC and the combustion of cyclopentane-polyurethane form occurred fiercely. It is considered that the recycling process of end-of-life home appliances using cyclopentane-polyurethane form as the insulator would require a special fire and dust explosion prevention measures since there exists a high potential hazard of fire and dust explosion during crushing and storage processes.