• Title/Summary/Keyword: house-values

Search Result 345, Processing Time 0.023 seconds

Analytical study of house wall and air temperature transients under on-off and proportional control for different wall type

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.1
    • /
    • pp.70-81
    • /
    • 2010
  • A mathematical model is formulated to study the effect of wall mass on the thermal performance of four different houses of different construction. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one -dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures is obtained using the Laplace transform method. Typical Meteorological Year data are processed to yield hourly average monthly values. These discrete data are then converted to a continuous, time dependent form using a Fast Fourier Transform method. This study is conducted using weather data from four different locations in the United States: Albuquerque, New mexico; Miami, Florida; Santa Maria, California; and Washington D.C. for both winter and summer conditions. A computer code is developed to calculate the wall temperature profile, room air temperature, and energy consumption loads. Three sets of results are calculated one for no auxiliary energy and two for different control mechanism -- an on-off controller and a proportional controller. Comparisons are made for the cases of two controllers. Heavy weight houses with insulation in mild weather areas (such as August in Santa Maria, California) show a high comfort level. Houses using proportional control experience a higher comfort level in comparison to houses using on-off control. The result shows that there is an effect of mass on the thermal performance of a heavily constructed house in mild weather conditions.

Prediction of Barge Ship Roll Response Amplitude Operator Using Machine Learning Techniques

  • Lim, Jae Hwan;Jo, Hyo Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.167-179
    • /
    • 2020
  • Recently, the increasing importance of artificial intelligence (AI) technology has led to its increased use in various fields in the shipbuilding and marine industries. For example, typical scenarios for AI include production management, analyses of ships on a voyage, and motion prediction. Therefore, this study was conducted to predict a response amplitude operator (RAO) through AI technology. It used a neural network based on one of the types of AI methods. The data used in the neural network consisted of the properties of the vessel and RAO values, based on simulating the in-house code. The learning model consisted of an input layer, hidden layer, and output layer. The input layer comprised eight neurons, the hidden layer comprised the variables, and the output layer comprised 20 neurons. The RAO predicted with the neural network and an RAO created with the in-house code were compared. The accuracy was assessed and reviewed based on the root mean square error (RMSE), standard deviation (SD), random number change, correlation coefficient, and scatter plot. Finally, the optimal model was selected, and the conclusion was drawn. The ultimate goals of this study were to reduce the difficulty in the modeling work required to obtain the RAO, to reduce the difficulty in using commercial tools, and to enable an assessment of the stability of medium/small vessels in waves.

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

The Buyers' Assessment of Purchasing Value of Housings (주택시장에서의 소비자의 구매가치평가)

  • 김윤정;강미선
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.23-33
    • /
    • 2000
  • Up until the mid-90s, the housing market of Korea has been supplier-oriented with the constant shortage of housing supply. But today, with the surplus of supply over demand and ever-increasing competitiveness in the housing market, understanding consumers needs have become one of the keys to successful business. Consumers overall living standard have increased and they are now looking for better living environment. As a matter of course, there have been much studies focusing on the evaluation factors and consumers preferences of the living environment, somewhat overlooking the asset value of a residential property. Consumers see their house in terms of both a living space and an asset. Therefore, it is these two values altogether that influences the buying decision process of consumers. This study seeks to stress on the importance of the fact that it is both the living environment and asset value of a house that are considered in the buyers valuation of residential property. And the study suggests that influencing factors of housing attributes in the decision-making process of buyers be sub-categorized into two broad groups, value as a living space and value as an asset. This is to serve both the researcher in the academic field and marketers for better understanding of consumers needs and influencing factors of buyers valuation of housings vis-a-vis market.

  • PDF

A Study on the Needs of the utilization and improvement of the multi-family housing residence (다가구.다세대주택 소유자의 주거환경 개선 및 활용 요구에 관한 연구)

  • Kim, Hye-Yeun;Lee, Young-Sun;Jang, Mi-Seon;Lee, Yeun-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.135-139
    • /
    • 2008
  • Through the industrialization since 1960, Korean housing has been developed in a uniform way which is to demolish first and then construct from the scratch. In this process, detached houses and multi-family living detached houses have disappeared without being paid much attention. The detached houses with blood or non-blood related multi-family living situations are typically popular, and worthy enough to explore for professionals right and creative solutions to enhance their values. But many of the people suffered for the expenses and the absence of the idea to enhance their housing themselves. The purpose of this research is to clarify user's demands of developing an adaptable lifespan house and to try to find the solution about the expenses of self improvement. This study used a Small group workshop Panel Method. The workshop consisted of three stage, such as the awareness of their existing residence and lease status, the needs of the housing improvements and the demands of the adaptable house. This study is expected to serve as a fundamental data to promote discussion on reuse of existing residence building and to promote rental detached houses.

  • PDF

Energy Saving Design Method with the Consideration of the Initial Cost for Apartment Houses (저에너지 공동주택 구현을 위한 요소기술 선정 기법에 관한 연구)

  • Son, Won-Tug;Lee, Jong-Il;Yoon, Dae-Won;Lee, Keon-Ho;Song, Doosam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.24-31
    • /
    • 2014
  • So many energy saving strategies to realize the low energy house are proposed in these days. Even if the energy saving performances are similar between the strategies, the costs are in abroad ranges. Therefore, the application of the energy saving strategies should be based upon two considerations; one is energy saving performance and the other is the cost. In this study, the decision making method for application of the passive design technologies in the design stage of the low energy apartment house are suggested. By utilizing the result of this study, practitioners can make an effective design alternatives which solve the conflicted values; energy saving and cost.

Application study of heat storage type GSHP system in Apartment building with central cooling and heating facilities using life cycle cost analysis (LCC 분석을 이용한 중앙공급식 공동주택의 수축열식 지열원 히트펌프시스템의 적용연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1497-1502
    • /
    • 2009
  • The present study has been conducted economic analysis of heat storage type ground source heat pump system(HSGSHP) and normal ground source heat pump (GSHP) and central boiler system with individual air conditioning facility which are installed at the same building in the shared an apartment house. Cost items, such as initial construction cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and simple payback period (SPP) with initial cost different are compared. The initial cost is a rule to the Government basic unit cost of production. LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are prices escalation rate and interest rate mean values of during latest 10 years. The LCC result shows that HSGSHP (1,351,000,000won) is more profitable than central boiler system with individual air conditioning facility by 86.7% initial cost. And SPP appeared 8.0 year overcome the different initial cost by different annual energy cost.

  • PDF

A Study on Developing Profit Model and Analyzing Validity for Remodelling of Apartment Houses (공동주택 리모델링의 수익모델 개발과 타당성 분석 연구)

  • Kim, Eui-Sik;Pyo, Ji-Myung;An, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.257-264
    • /
    • 2004
  • The physical factor having a great influence among components of making values of profit model in apartment houses is equilibrium change of house and this study suggests an alternative of remodelling. It sets profit models including model dividing household of large scale into that of small scale using value making factor of apartment house and spatial composition techniques and model integrating households of small scale and converting them into those of large scale and finds that its economy is good as over 'average', evaluative value of economy is reduced as discount rate increases and economy of remodelling is superior.

ASSESSMENT OF STABILITY MAPS FOR HEATED CHANNELS WITH SUPERCRITICAL FLUIDS VERSUS THE PREDICTIONS OF A SYSTEM CODE

  • Ambrosini, Walter;Sharabi, Medhat Beshir
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.627-636
    • /
    • 2007
  • The present work is aimed at further discussing the effectiveness of dimensionless parameters recently proposed for the analysis of flow stability in heated channels with supercritical fluids. In this purpose, after presenting the main motivations for the introduction of these parameters in place of previously proposed ones, additional information on the theoretical bases and on the consequences of this development is provided. Stability maps, generated by an in-house program adapted from a previous application to boiling channels, are also shown for different combinations of the operating parameters. The maps are obtained as contour plots of an amplification parameter obtained from numerical discretization and subsequent linearization of governing equations; as such, they provide a quantitatively clear perspective of the effect of different boundary conditions on the stability of heated channels with supercritical fluids. In order to assess the validity of the assumptions at the basis of the in-house model, supporting calculations have been performed making use of the RELAP5/MOD3.3 computer code, detecting the values of the dimensionless parameters at the threshold for the occurrence of instability for a heated channel representative of SCWR proposed core configurations. The obtained results show reasonable agreement with the maps, supporting the applicability of the proposed scaling parameters for describing the dynamic behaviour of heated channels with supercritical fluids.

Characteristics of Photo-conversion Glass with $Eu^{3+}$ and Its Use 2 (Effect of Photo-conversion on Vegetables Growth) ($Eu^{3+}$가 첨가된 광변환 유리의 특성과 효과연구 2(유리의 채소재배 효과))

  • Chung, Hun-S.;Ahn, Yang-K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.62-67
    • /
    • 2002
  • Energy conversion soda-lime-silica glasses doped with Eu3+ were produced and they were used to build small scale modules of $100\times100cm$ simulating the roof of glass house with which the rearing state of a small number of young and grown vegetables was observed. The vegetables selected for the study were eggplant, kale, and pimento. The width and length of their leaves along with the photosynthesized ability and chlorophyl content were measured to observe the growing state of the vegetables in the given periods of time. It was found that the vegetables grown under the photo-conversion glass made panels had higher values of the leaf width and length by 5 to 30% than them under the commercially available ordinary glass panels depending on the kind of vegetables. The photosynthesized abilities were also shown much higher for the vegetables under the conversion glass panels than for the non-conversion ones.