• Title/Summary/Keyword: house of quality

Search Result 921, Processing Time 0.024 seconds

Component Quality Certification System for Evaluation and Certification of COTS Components (COTS 컴포넌트의 평가 및 인증을 위한 컴포넌트 품질 인증 시스템)

  • 김수동;박지환;김남희
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1135-1148
    • /
    • 2003
  • A commercial-off-the-shelf (COTS) component is an implementation of common functionality among family members, where an in-house component implements an organization-specific functionality. Typically, a COTS component has a producer and aset of potential consumers. Consumers evaluate COTS components thoroughly before they purchase, because these components are developed by third party producers and most consumers have ‘not-invented-here’ syndrome. Hence, evaluating the quality of COTS components becomes an important prerequisite to a successful component-based application development. In this paper, we identify the characteristics of COTS components, and derive a practical quality model for components, C-QM, which consists of quality factors, criteria and metrics and a qualify certification system, C-QCS. The top design goal of C-QM is set to provide a practically applicable comprehensive quality model which can be effectively applied in assessing the various quality aspects of COTS components.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House (새송이버섯 재배사의 환경요인 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.12 no.4
    • /
    • pp.200-206
    • /
    • 2003
  • Pleurotus eryngii(King oyster) is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the year round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation house(A,B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. this experiment was conducted for about two-month from Nov. 11, 2002 to Dec. 30, 2002 in Eryngii. cultivation house-A, B. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Maximum air temperature difference between the upper and lower growth stage during a heating time zone was about 2~3$^{\circ}C$. The max. and min. relative humidity were ranged approximately 60~100%, and average relative humidity was ranged approximately 80~100%. And $CO_2$concentration increased until maximum 1,600~1,800 ppm with the passing growing period. The illuminance in cultivation house was widely distributed from 20lx to 160 lx in accordance with position, and it was maintained lower than the recommended illuminance range 100~200 lx. The average yield per bottle was about 67~85g. But the optimal productivity will be evaluated by considering the quality and quantity of mushroom production, energy requirements, facility construction and management cost, etc.

A Conceptual Framework of IoT Case Study (IoT 사례분석을 위한 개념적 틀 제시)

  • Jeon, Ka Young;Lee, Jang Hyuk;Oh, Jungsuk
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.3
    • /
    • pp.123-131
    • /
    • 2015
  • With a prospective of rapid deployment of IOT, a systematic approach to derive a business strategy for various possible scenarios of IOT applications is in great demand. In this paper, a conceptual framework that can be utilized for the purpose of assessing the market potential and of setting up an initial business strategy for IOT deployment is suggested. The framework consists of utilization of well-known value curve analysis, ecosystem analysis and house of quality tools. The value curve analysis is utilized to identify value-enhancing components of consumers as well as relative strengths of suppliers. The ecosystem analysis is used to identify relevant players of the supply chain and their mutual relationships. The house of quality is suitable for developing the initial business strategy of the supplier by converting consumer requirements identified by value curve analysis into technical requirements for the supplier. In this paper, we applied our proposed framework to two services that have high potentiality of being benefited by IOT: car-sharing service and telehealth service.

  • PDF

Exploring an Instrumental Measurement of Quality of Housing Environment (주거환경의 질 척도에 관한 연구)

  • 박정희
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.71-84
    • /
    • 1994
  • This article tries to develop an instrument for assessing the quality of housing environment by using 67 housing environment variables. The method of factor analysis is used to explore the dimension of the quality of housing. As the result, 5 dimensions of housing environment are extracted. They are, according to the order of their importances, house structure and indoor environment, outdoor facilities and natural environment, indoor facilities and economy, public facilities and social relationship, and convenient facilities and residential feasibility.

  • PDF

The Effect on the Granodiorite Suspension Coated Indoor Finishing Materials for Reduction of TVOC Emissions (실내 마감재료의 TVOC 방출 저감을 위한 화강섬록암 현탁액 도포효과)

  • Lee, Jong-Gyu;Kim, Ji-Hyun;Lee, Jae-Yong;Lee, Soo-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.93-99
    • /
    • 2008
  • The environment draws attention in the global community and a growing number of Koreans have interest in improving the quality of life, the importance of house environment has attracted the attention of the public. Against this backdrop, constructors have unveiled environmentally -friendly projects. However, they failed to establish people-oriented environment by being occupied with maximizing profitability through the improvement of brand image and caused sick house syndrome that has recently made controversy. In this regard, the study analyzed the mechanism of discharge of TVOC, one of the sick house syndrome-causing materials, that affects IAQ and its characteristics and examined the effect that granodiorite has on reduction of the discharge of TVOC in order to minimize damage. Experimental sample consisted of interior finishing materials frequently used in ceiling, wall and floor and adhesives used at a time of construction, and the TVOC of building materials was measured through the use of septum bottle unlike In the existing chamber method. Measures to counter the sick house syndrome were suggested by reducing the possible damage from the stage of selection of building material and by figuring out the effect that the granodiorite has on reduction of the discharge of TVOC.

The Study on the Renovation Method of Apartment House Ventilation System for Reducing Indoor Air Contamination (실내오염 저감을 위한 공동주택 환기시스템의 개선방안에 대한 연구)

  • Hwang, Tae-Chul;Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.409-415
    • /
    • 2008
  • Recently, Indoor air quality (IAQ) is one of the most important problem in our daily life of modern societies. Mechanical ventilation system is being recommended as an effective method to improve IAQ in apartment houses. And then, in Korea, building industry should install ventilation system in apartment house by the building construction code. In this study, to improve IAQ caused by microbial and chemical contaminant such as bacteria and TVOC, three types of mechanical ventilation system of apartment house including HRV were simulated by multizone modeling. Simulation results suggest an appropriate and economical renovation method of apartment house ventilation system for reducing indoor air contamination.

A Diagnostic Study on the Development of a Health Promotion Program for Vinyl House Farmers (비닐하우스 농작업자 건강증진프로그램 개발을 위한 진단적 연구)

  • Kim, Chung-Nam;Lim, Kyung-Soon
    • Research in Community and Public Health Nursing
    • /
    • v.18 no.1
    • /
    • pp.90-101
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate influencing factors of health problems which the vinyl house farmers had experienced. Method: Based on PRECEDE model, this study was done with 110 respondents(50 to 69 years old), working in vinyl house and living in the remote area where the primary health post located. Results: Quality of life was low in economical status, emotional status, and physical function. Health problems were founded as pain and chronic fatigue that were caused by physical symptoms, weakened physical strength, and increased blood pressure and cholesterol. Behavioral and environmental factors were related with lack of exercise, irregular eating habit, curtailed sleep, overwork, wrong working postures, stress, and non-fulfillment of safety standard during spraying pesticide. Self efficacy was low in excercise practice, working way, and stress management. Conclusion: The Health Promotion Program for vinyl house farmers should be developed to improve health promoting behavior and self efficacy, to reduce stress, and to strengthen physical function.

  • PDF

Influence of Forcing Cultivation Time on Cut Flower, Root Quality, and Yield in Peony (Paeonia lactiflora Pall. cv. Taebaek) (작약 촉성재배 시기가 절화와 뿌리품질 및 수량에 미치는 영향)

  • Bae, Su-Gon;Kim, Jwoo-Hwan;Park, Sang-Jo;Kim, Jae-Cheol
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.6
    • /
    • pp.421-426
    • /
    • 2008
  • Three year-old peony (Paeonia. lactiflora Pall. cv. Taebaek) was cultivated in green-house at Jan. 15, Feb. 15, or Mar. 15, respectively. The mean of temperature during the forcing cultivation was higher (air; $1.0{\sim}11.1^{\circ}C$, soil; $1.1{\sim}7.4^{\circ}C$) than that of open-field condition. From sprouting to flowering in peony cultivated at Jan. 15 was about 54 days, which is shorted the cut flower periods (ca. 26 days) compared with the open-field cultivation. However, earlier forcing cultivars were very susceptible to pathogens such as powdery mildew or gray mold. The yield in green house was also lower than in the open-field cultivation. The content of bioactive compounds such as paeoniflorin and albiflorin in green-house cultivars was similar that of open-field cultivars. These results showed the forcing cultivation time of peony at Feb. 15 in green-house was most desirable for commercialization.

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu (대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가)

  • Park, Hyun-Sik;Kim, Hyun-Tae;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season (흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구)

  • Chan, Kook;Jeon, Ji-Hyeon;Shin, Yong-Gyu
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.