• 제목/요약/키워드: hourly total solar radiation

검색결과 11건 처리시간 0.03초

온실의 광환경 분석을 위한 기초실험 (The Basic Experiments for Analysis of Solar Radiation Environemnts in Greenhouse)

  • 이현우;이석건;김길동;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.434-438
    • /
    • 1999
  • It was neede to know the amount of PAR to predict the growth of crops, and the quantity of total radiation to control the temperature by shading screen in the greenhouse. Experiments have been conducted to determine the correlation between the hourly PAR and total solar radiation the transmisson of PAR and total solar radiaiton oat canopy location, and the relationship between the illuminaance and total solar radiation. Additional experiments are needed to confirm thses experimental results.

  • PDF

기상조건에 따른 온실의 전천일사량 및 광합성유효광량자속의 상관관계 및 투과율 (Relationship between Total Solar Radiation and PPF, and Transmittance in Greenhouse at Different Weather Conditions)

  • 이현우;이석건;이상호
    • 생물환경조절학회지
    • /
    • 제11권2호
    • /
    • pp.56-60
    • /
    • 2002
  • 온실의 경우 구조재가 광투과율에 많은 영향을 주기 때문에 기상조건에 따라 달라지는 산란광과 직달광의 비율에 따라 투과율이 달라질 수 있다 따라서 기상조건에 따른 온실내부의 광투과율을 구명할 필요가있다. 전천일사량은 기상청에서 제공하는 기상자료에서 쉽게 얻을 수가 있는 반면에 광합성유효광량자속의 자료는 직접 측정하지 않고는 구하기가 어렵다. 그러나 전천일사량과 광합성유효광량자속의 상관관계가 얻어지면 전천일사량으로부터 광합성유효광량자속을 쉽게 구할 수가 있을 것이다. 따라서 우리나라 온실에 대하여 기상조건에 따라 광합성유효광양자속을 산정할 수 있는 상관식의 개발이 필요하다. 본 연구는 실험을 통하여 온실의 수관부에서의 기상조건에 따른 광합성유효광량자속의 투과율을 산정하고 전천일사와 광합성 유효광량자속과의 상관관계를 구명하기 위하여 수행되었다. 산란광이 많은 흐린 날과 직달광이 많은 맑은날의 투과율 변화는 상당한 차이가 있음을 확인할 수 있었으며, 온실의 투과율은 기상조건에 따라 다르게 적용되어야 할 것으로 판단되었다. 온실의 전천일사량 투과율을 광합성유효광량자속의 투과량을 산정하는데 그대로 이용할 수 있을 것으로 분석되었다. 비록 맑은 날에 비하여 흐린 날의 상관도는 낮지만 상관식의 기울기는 큰 것으로 나타나 운량의 증가와 더불어 전천일사량 중에서 광합성유효광량자속의 비율이 증가하는 것을 확인 할 수 있었다. 시간당 광합성유효광량자속과 전천일사량의 상관식을 유도하였으며, 이러한 상관식을 이용한다면 시간당 전천일사량을 이용하여 시간당 광합성유효광량자속을 추정하는데 적절히 이용할 수 있을 것으로 판단된다.

운량 비측정 지역을 위한 수평면전일사량 예측 상관식의 수정모델 제안 (Proposal of Modified Correlation to Calculate the Horizontal Global Solar Irradiance for non-Measuring Cloud-cover Regions)

  • 조민철;김정배
    • 융복합기술연구소 논문집
    • /
    • 제6권2호
    • /
    • pp.29-33
    • /
    • 2016
  • Recently, the authors of this paper proposed newly the correlation model to calculate the horizontal global solar radiation in Korea based the Zhang-Huang (ZH) model proposed in 2002 for China. Previous study was pronounced the correlation with a new term of the duration of sunshine proved as being closely related with the hourly solar radiation in Korea into ZH model. And then another modified correlation for the regions without measuring cloud cover was proposed and evaluated the accuracy and validity for those regions. So, this study was performed to propose modified correlation to calculate the horizontal global solar irradiance of non-measuring cloud-cover regions. Finally, this study proposed the new correlation that could well predict hourly and daily total solar radiation for all regions, various seasons, and various weather conditions including overcast and clear, with higher accuracy and lower error than other models proposed ever before in Korea for non-measuring cloud-cover regions.

서울의 일사 대기투과율에 관한 연구 (Atmospheric Transmittance of Solar Radiation for Seoul)

  • 김두천;김정희
    • 대한설비공학회지:설비저널
    • /
    • 제16권4호
    • /
    • pp.375-382
    • /
    • 1987
  • Accurate solar radiation data are fundamental to the design of HVAC systems and solar driven devices. Unfortunately, the total radiation data on a horizontal surface has been only reported by meteorological office. Consequently, there is interest in development of model to estimate the solar radiation data. Based on the statistically estimated TAC data which were obtained from measured hourly values collected over a period of ten years at Seoul, the solar radiation model was determined. Atmospheric transmittance for this model was presented in the form of polynominal.

  • PDF

온실의 전천일사량 및 광합성광량자속의 상관관계 및 투과율 (The Relationship between Solar Total Radiation and Solar PPF and Transmission in Greenhouse)

  • 이현우;이석건;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.261-266
    • /
    • 2001
  • It was needed to know the amount of PPF to design greenhouse and predict the growth of crops in greenhouse. Experiments have been conducted to determine the transmission of PPF at canopy level along sky clearness condition in greenhouse, the correlation between the hourly PPF and total solar radiation. Additional experiments are needed to confirm these experimental results.

  • PDF

청주지방(淸州地方)의 시청명지수(時淸明指數)와 산란비(散亂比)와의 관계(關係)(II) (Relationship between Hourly Clearness Index and Diffuse Ratio at Cheongju Area(II))

  • 이홍주
    • Journal of Biosystems Engineering
    • /
    • 제13권2호
    • /
    • pp.46-50
    • /
    • 1988
  • The estimation of beam radiation intensity on a tilted surface is very important to the design of a solar energy system. In order to get the beam radiation intensity, it is required to calculate the ratio of the diffuse solar radiation to the global radiation ($k_d$). The data measured at Chung-Buk National University. Cheong-ju, (from May 16, 1985 to Nov, 10, 1987) were analysed to define the relationship between hourly clearness index ($k_t$) and diffuse ratio ($t_d$). The results are is follow: 1. The percent of clearness index($k_t$) of less than 0.3 and of more than 0.8 were 2.7% and 3.1% respectively, and between 0.5 and 0.8 was 76.5%. 2. The regression equation between $k_t$ and $k_d$ was an exponential function as: $$k_d=\[{1\hspace{120}:\hspace{10}(k_t<0.1)\\1.28{\times}0.074^{k_t}\hspace{30}:\hspace{10}(0.1{\leq}=k_t<0.9)\\0.12\hspace{98}:\hspace{10}(0.9{\leq}=k_t)$$ There was a little difference between the result. of this study based on the data of 30 months and the results of previous study (ITRA 2(1):42-47, 1986.) based on the data of 8 months. 3. The hourly exponential regression equation between $k_t$ and $k_d$ was $k_d=A{\times}8^{k_t}$ and the values of constant A and coefficient B of the: equations are as the following table; 4. The percent of $k_d$ of less than 0.4 was 72.9% and of more than 0.7 was 6.6%. 5. Total mean value of $k_t$ and $k_d$ wert 0.56 and 0.32, respectively. From 10:00 to 15:00 o'clock the total mean value of $k_t$ was smaller that the hourly man value of $k_t$ and the one or $k_d$ larger.

  • PDF

위성자료기반의 한반도 태양기상자원지도 개발 (The Development of the Solar-Meteorological Resources Map based on Satellite data on Korean Peninsula)

  • 지준범;최영진;이규태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.342-347
    • /
    • 2011
  • Solar energy is attenuated by absorbing gases (ozone, aerosol, water vapour and mixed gas) and cloud in the atmosphere. And these are measured with solar instruments (pyranometer, phyheliometer). However, solar energy is insufficient to represent detailed energy distribution, because the distributions of instruments are limited on spatial. If input data of solar radiation model is accurate, the solar energy reaches at the surface can be calculated accurately. Recently a variety of satellite measurements are available to TERA/AQUA (MODIS), AURA (OMI) and geostationary satellites (GMS-5, GOES-9, MTSAT-1R, MTSAT-2 and COMS). Input data of solar radiation model can be used aerosols and surface albedo of MODIS, total ozone amount of OMI and cloud fraction of meteorological geostationary satellite. The solar energy reaches to the surface is calculated hourly by solar radiation model and those are accumulated monthly and annual. And these results are verified the spatial distribution and validated with ground observations.

  • PDF

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

우리나라의 기후 변화 영향에 의한 건물 냉난방에너지 수요량 변화의 예측 (Prediction on Variation of Building Heating and Cooling Energy Demand According to the Climate Change Impacts in Korea)

  • 김지혜;김의종;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.789-794
    • /
    • 2006
  • The potential impacts of climate change on heating and cooling energy demand were investigated by means of transient building energy simulations and hourly weather data scenarios for Inchon. Future trends for the 21 st century was assessed based oil climate change scenarios with 7 global climate models(GCMs), We constructed hourly weather data from monthly temperatures and total incident solar radiation ($W/m^2$) and then simulated heating and cooling load by Trnsys 16 for Inchon. For 2004-2080, the selected scenarios made by IPCC foresaw a $3.7-5.8^{\circ}C$rise in mean annual air temperature. In 2004-2080, the annual cooling load for a apartment with internal heat gains increased by 75-165% while the heating load fell by 52-71%. Our analysis showed widely varying shifts in future energy demand depending on the season. Heating costs will significantly decrease whereas more expensive electrical energy will be needed of air conditioning during the summer.

  • PDF

Analysis of Solar Irradiance Measurement From a Multi-Filter Radiometer At Kwangju, South Korea.

  • Ogunjobi, K.O.;Kim, Y.J.;He, Z.;Ryu, S.Y.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.335-335
    • /
    • 2001
  • Direct-normal, total horizontal and diffuse horizontal irradiance data obtained from a multi-filter rotating shadowband radiometer over seven different wavelength bands (416nm, 151nm, 616nm, 675nm, 870nm and 940nm and the entire spectrum) has been analyzed at Kwangju, South Korea from June 1998 December 2000. The maximum hourly global radiation flux ranged from 0.44 MJ/$m^2$ to 2.68 MJ/$m^2$ at around 11:00-12:00 Hr local time while the maximum hourly diffuse radiation flux ranged from about 0.96 MJ/$m^2$ to 1.37 MJ/$m^2$. The maximum hourly direct irradiance ranged from 1.42 MJ/$m^2$ to 2.92 MJ/$m^2$ from June1998-2000. During the period under consideration, the average monthly global radiation recorded were 13.09 MJ/$m^2$/day, 10.58MJ/$m^2$/day and 9.78MJ/$m^2$/day for years 1998, 1999 and 2000 respectively, while the diffuse irradiance were 6.54 MJ/$m^2$/day, 5.33 MJ/$m^2$/day and 5.14 MJ/$m^2$/day for f998, 1999 and 2000 respectively. The direct irradiance values at the site were 11.63 MJ/$m^2$/day, 8.24MJ/$m^2$/day and 7.75 MJ/$m^2$/day for 1998, f999 and 2000 respectively. It was observed that each of the years has its own unique meteorological parameters that affect the quality and quantity of radiation received for each month. The annual average daily fractions of the diffuse to the global radiation (KD) were 0.51, 0.61 and 0.59 for years 1998, 1999 and 2000 respectively. Analysis indicated that the average daily KD ranged from 0.13 to a maximum value of 0.99 in May for irradiance measured at the broadband channel while the maximum and minimum KD value of 0.91 and 0.23 was recorded at wavelength band 870nm and 940nm in January and September respectively. The lowest average daily clearness index (Kt) value recorded was 0.03 in May (Spring) and the annual average daily clearness indexes are 0.45, 0.34 and 0.35 for years 1998, f999 and 2000 respectively. The frequency of clear days annually at Kwangju is 67.95%, 29.57% and 40.72% for years 1998, 1999 and 2000 respectively.

  • PDF