Ar-He 혼합가스와 hot-wire를 이용한 협개선 TIG 용접에 관한 연구 (Study on Narrow groove TIG welding using Ar-He of shielding gas & hot wire)

  • 최준태;박종련;김대순
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.346-348
    • /
    • 2005
  • TIG welding can produce high quality of weld, but has the disadvantage of low productivity and high possibility of lack-of-fusion especially on heavy wall groove welding. In order to overcome such demerits of TIG welding, the hot-wire method which provides pre-heated wire and the use of He-Ar mixture gas as shielding gas were adopted. Through this study, both methods were turned out to be beneficial to the prevention of lack-of-fusion and the increase of productivity and welding speed.

  • PDF

비전시스템에 의한 열간 선재 단면 측정 (Measurement of Hot WireRod Cross-Section by Vision System)

  • 박중조;탁영봉
    • 제어로봇시스템학회논문지
    • /
    • 제6권12호
    • /
    • pp.1106-1112
    • /
    • 2000
  • In this paper, we present a vision system which measures the cross-section of a hot wire-rod in the steel plant. We developed a mobile vision system capable of accurate measurement, which is strong to vibration and jolt when moving. Our system uses green laser light sources and CCD cameras as a sensor, where laser sheet beams form a cross-section contour on the surface of the hot wire-rod and the reflected light from the wire-rode is imaged on the CCD cameras. We use four lasers and four cameras to obtain the image with the complete cross-section contour without an occlusion region. We also perform camera calibrations to obtain each cameras physical parameters by using a single calibration pattern sheet. In our measuring algorithm, distorted four-camera images are corrected by using the camera calibration information and added to generate an image with the complete cross-section contour of the wire-rod. Then, from this image, the cross-section contour of the wire-rod is extracted by preprocessing and segmentation, and its height, width and area are measured.

  • PDF

분말송급 및 와이어송급을 이용한 레이저 클래딩 특성 (Comparison of Powder Feeding and Wire Feeding in Laser Cladding)

  • 안영남;김철희
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.13-16
    • /
    • 2013
  • In this research, laser cladding characteristics were investigated for various filler metal feeding methods such as powder, cold wire, and hot wire feeding. Appropriate parameter window, deposition rate, material efficiency and dilution for each filler feeding method were evaluated with same laser power and cladding speed range. Laser powder cladding has wider process parameter window but higher material efficiency and lower dilution were achieved by laser wire cladding. Among these feeding methods, laser hot-wire cladding showed best efficiency in material usage and deposition rate.

열선에 사용되는 새로운 요각함수의 제안 (Proposition of a new yaw function for the use of hot wire)

  • 김정훈;유정열;조성권
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.131-138
    • /
    • 1998
  • Conventional yaw functions are compared with actual response of a hot wire to various yaw angles, and a new function is proposed, which can be applied at large yaw angles and low velocities. To compare the accuracy of the new yaw function with those of the conventional ones, measurements are made for the jet flow at the nozzle exit and at .chi./D=15 with an X hot-wire probe. In the potential core, the flow angles reduced by the present function, ideal angle method and full velocity-angle method are shown to be more accurate than those reduced by the cosine function and Hinze's formula. No matter which yaw functions are used, the profiles of mean velocity and turbulence intensity show little discrepancy at .chi./D=15. However, there is a significant difference between the probability density functions obtained by the present function, ideal angle method and full velocity-angle method and those obtained by the cosine function and Hinze's formula.

광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구 (Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

단순변형률 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트내 외향 난류유동 측정 (Measurement of Outward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section)

  • 오창민;최영돈
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.623-631
    • /
    • 2000
  • Hot-wire measurements were carried out on the developing turbulent flows subject to plane rate of strain in a rotating curved duct. The cross-section of the curved duct varies from 100mm${\times}$50mm rectangular shape at the bend inlet gradually to the 50mm${\times}$100mm rectangular shape at the bend outlet. Experimental setup consists of the test section of $90^{\circ}$ curved duct, rotating disc of 1.95m diameter, Ag-Ni precision slip ring, automatic traversing mechanism, variable speed motor, centrifugal blower, orifice flowmeter and hot-wire anemometer. Data signals from the rotating curved duct are transmitted through the slip ring to the computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynold stresses components were obtained from the fluctuating and mean voltage measured by the slant type hot-wire probe rotating into 6 orientations. We investigate the effects of Coriolis and centrifugal forces on the turbulence structure.

덕트의 유무에 따른 Gun식 가스버너의 난류유동장 특성 고찰 (Investigation on the Turbulent Flow Field Characteristics of a Gun-Type Gas Burner with and without a Duct)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.17-24
    • /
    • 2006
  • The turbulent flow field characteristics of a gun-type gas burner with and without a duct were investigated under the isothermal condition of non-combustion. Vectors and mean velocities were measured by hot-wire anemometer system with an X-type hot-wire probe in this paper. The turbulent flow field with a duct seems to cause a counter-clockwise recirculation flow from downstream to upstream due to the unbalance of static pressure between a main jet flow and a duct wall. Moreover, the recirculation flow seems to expand the main jet flow to the radial and to shorten it to the axial. Therefore, the turbulent flow field with a duct increases a radial momentum but decreases a axial momentum. As a result, an axial mean velocity component with a duct above the downstream range of about X/R=1.5 forms a smaller magnitude than that without a duct in the inner part of a burner, but it shows the opposite trend in the outer part.

  • PDF