• 제목/요약/키워드: hot-tube test

검색결과 58건 처리시간 0.029초

폴리올에스테르의 합성 및 열안정성 (Synthesis and Thermal Stability of Polyol Esters)

  • 백진욱;정근우;김영운;서인옥;한정식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.130-134
    • /
    • 2002
  • Polyol esters were synthesized by condensation reaction of polyols (PE and DIPE) and linear acids such as valeric acid, caproic acid, heptylic acid and caprylic acid. The structures of polyol esters were confirmed by gas chromatography. Hot tube test was used to measure thermal stability of polyol esters and its thermal properties depended on the structure of acid moiety contained in polyol esters.

  • PDF

교육시설에 적용 가능한 태양열 흡수식 냉각 시스템 (Solar Absorption Cooling System applicable to Educational Facilities)

  • 윤성민;백인수;한영태;남효갑
    • 교육시설 논문지
    • /
    • 제18권3호
    • /
    • pp.35-41
    • /
    • 2011
  • Performance of a small-capacity solar absorption cooling system was investigated experimentally. Ten sets of evacuative-tube solar-heat collectors and a 5 kW single-stage absorption cooler were combined to produce a hybrid cooling system. The performance of the cooling system was measured using a tim-coil unit installed in a small plastic storage. It was found from the test on a sunny day of May that when the temperature of the hot water supplied from the solar collectors to the generator of the absorption cooler reached $60^{\circ}C$, the absorption cooler started cooling and the cold water temperature measured from the fan-coil unit reached $18^{\circ}C$. The COP, which is defined as the ratio of the cooling power to the total electrical power input was higher than 1.0.

  • PDF

열전냉각소자와 열전발전소자의 발전특성 (Characteristics of electric power for thermoelectric cooling & generating module)

  • 우병철;이희웅;이동윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.448-451
    • /
    • 2000
  • The purpose of this study is to manufacture and test a thermoelectric generator which converts unused energy from close-at-hand sources, such as garbage incineration heat and industrial exhaust, to electricity. A manufacturing process and the properties of a thermoelectric generator are discussed before simulating the thermal stress and thermal properties of a thermoelectric module located between an aluminum tube and alumina plate. We can design the thermoelectric modules having the good properties of thermoelectric generation. Resistivity of thermoelectric module for thermoelectric generation consisting of 62 cells was 0.15-0.4$\Omega$ Developed thermoelectric modules can be expected th have better properties than thermoelectric cooling modules above $70^{\circ}C$ in temperature difference between hot and cold ends.

  • PDF

Fatigue performance and life prediction methods research on steel tube-welded hollow spherical joint

  • Guo, Qi;Xing, Ying;Lei, Honggang;Jiao, Jingfeng;Chen, Qingwei
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.75-86
    • /
    • 2020
  • The grid structures with welded hollow spherical joint (WHSJ) have gained increasing popularity for use in industrial buildings with suspended cranes, and usually welded with steel tube (ST). The fatigue performance of steel tube-welded hollow spherical joint (ST-WHSJ) is however not yet well characterized, and there is little research on fatigue life prediction methods of ST-WHSJ. In this study, based on previous fatigue tests, three series of specimen fatigue data with different design parameters and stress ratios were compared, and two fatigue failure modes were revealed: failure at the weld toe of the ST and the WHSJ respectively. Then, S-N curves of nominal stress were uniformed. Furthermore, a finite element model (FEM) was validated by static test, and was introduced to assess fatigue behavior with the hot spot stress method (HSSM) and the effective notch stress method (ENSM). Both methods could provide conservative predictions, and these two methods had similar results. However, ENSM, especially when using von Mises stress, had a better fit for the series with a non- positive stress ratio. After including the welding residual stress and mean stress, analyses with the local stress method (LSM) and the critical distance method (CDM, including point method and line method) were carried out. It could be seen that the point method of CDM led to more accurate predictions than LSM, and was recommended for series with positive stress ratios.

쉘-튜브 열교환기에서의 쉘쪽 유체의 특성에 따른 열교환기 성능 변화 예측 사례 (Shell and Tube Heat Exchanger Performance Estimation by Changing Shell-side Fluid Characteristics)

  • 백승환;정영석;조기주
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.27-37
    • /
    • 2019
  • 쉘-튜브 열교환기가 나로우주센터 추진기관종합시험장(PSTC)에 설치되었으며, 이 열교환기는 극저온의 헬륨을 고온의 열매유와 열교환하여 약 500 K 까지 가열시키는 역할을 한다. 열교환기에서 토출되는 헬륨의 온도가 설계보다 100 K 낮게 나옴에 따라, 성능저하의 원인으로 열매유의 격막효과가 지목되었다. CFD 해석을 통해 격막효과의 유무를 확인하였으며, 격막효과에 의한 열교환기 성능저하는 미미한 것으로 판단되었다. 추가적으로 열교환기의 성능을 증가시키기 위하여 열매유 교체에 따른 열교환기 성능 변화를 알아보았다. 열매유를 사용하는 열교환기의 성능향상을 위해서는 500 K 부근에서 점성이 낮아야 하고, 열전도도가 높아야 한다는 것을 확인할 수 있었다. 추진기관종합시험장에서 운용된 극저온 헬륨과 고온 열매유의 열교환 시스템의 시험 결과를 본 논문에서 확인할 수 있다.

원자력 발전 주기기 제작에 적용되는 용접공정 (Welding process for manufacturing of Nuclear power main components)

  • 정인철;김용재;심덕남
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.43-46
    • /
    • 2010
  • As the nuclear power plant has been constructed continuously for several decades in Korea, the welding technology for components manufacturing and installation has been improved largely. Standardization for weld test and qualification was also established systematically according to the concerned code. The welding for the main components requires the high reliability to keep the constant quality level, which means the repeatability of weld quality. Therefore the weld process qualified by thorough test and evaluation is able to be applied for manufacturing. Narrow gap SAW and GTAW process are usually applied for girth seam welding of pressure vessel like Reactor vessel, steam generator, and etc. For the surface cladding with stainless steel and Inconel material, strip welding process is mainly used. Inside cladding of nozzles is additionally applied with Hot wire GTAW and semi-auto welding process. Especially the weld joint having elliptical weld line on curved surface needs a specialized weld system which is automatically rotating with adjusting position of the head torch. The small sized pipe, tube, and internal parts of reactor vessel requests precise weld processes like an automatic GTAW and electron beam welding. Welding of dissimilar materials including Inconel690 material has high possibility of weld defects like a lack of fusion, various types of crack. To avoid these kinds of problem, optimum weld parameters and sequence should be set up through the many tests. As the life extension of nuclear power plant is general trend, weld technologies having higher reliability is required gradually. More development of specialized welding systems, weld part analysis and evaluation, and life prediction for main components should be taken into a consideration extensively.

  • PDF

직접 수송 루프에서 아이스슬러리의 열전달 특성에 관한 실험적 연구 (Experimental Study on Heat Transfer Characteristics of Ice Slurry at Direct Transportation Loop)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제19권4호
    • /
    • pp.234-239
    • /
    • 2010
  • 원형 파이프를 유동하는 6.5% EG 수용액으로부터 만들어진 아이스슬러리의 열전달 특성을 분석하기 위한 실험을 수행하였다. 실험 장치의 시험부는 13.84 mm 내경과 1,500 mm의 길이를 가진 동관으로 제작되었다. 아이스슬러리는 시험부 주변에 이중관 형태로 만들어진 원형관 내부를 유동하는 온수에 의해 가열되었다. 본 연구의 실험에 적용된 IPF와 질량 유속은 각각 0 ~ 25% 그리고 1000 ~ 3,000 kg/$m^2s$의 범위이었고, 온수의 온도와 유량은 일정하게 유지하였다. 측정된 열전달량은 질량 유량과 IPF가 증가함에 따라 증가하였으나, IPF의 영향은 높은 질량 유량에서는 작은 것으로 나타났다. 낮은 질량유량에서는 열전달 계수의 급격한 상승이 15 ~ 20%의 IPF에서 나타났다. 마지막으로 측정된 열전달계수는 기존의 열전달상관식들에 의해 계산된 열전달계수와 비교하여 제시하였다.

지하수 이용을 위한 열교환기 개발. I - 냉각핀의 설계제작 - (Development of heat exchanger by the utilization of underground water. I - Design for plat fin tube -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.119-127
    • /
    • 2002
  • 지하수의 열(15℃)을 농업시설의 난방과 냉방에 사용하기 위하여, 관에 종방향으로 부착되는 plat fin tube 형 알루미늄(Al 6063) 열교환기를 개발하여 알루히트(의장등록 : 0247164)로 명명하였다. 열교환 핀을 관에 종방향으로 배치하여 송풍과 대류에 유체 흐름저항을 최소화 하였으며, 핀표면에 돌기를 만들어 결로와 fouling factor를 감소시켰다. 1. 알루히트의 제원은 관 내경 0.03m, 외경 0.036m, 두께 0.003m이며, 냉각핀의 두께 0.0012m, 핀 길이 0.032m로 하였다. 2. 단위 길이당 관 외부의 전열면적은 1.3946m2이며, 관내부 전열면적은 0.0942m2였고, 내외면적비 Ra = 14.805였다. 3. 핀의 길이 0.032m로 하였을 때, 핀의 효율이 93%정도인 것으로 나타났으며, 핀두께 0.0012m는 h𝛿/k<0.2를 만족하여 적합한 것으로 판단된다. 4. 알루히트의 온수 방열 성능실험에서 열매체의 온도가 높고 유량이 많을수록 방열 열량이 많은 것으로 나타났고, 열매체의 온도 60℃, 유량 10 𝑙/min일 때 방열열량은 504kJ/h·m 였으며, 80℃, 40 𝑙/min일 때는 방열열량이 6,048kJ/h·m로 나타났다. 5. 방열성능에서 각각의 열매체 온도간 상관계수 $R^2_1=0.9898$, 유량간 상관계수 $R^2_2=0.9721$로 실험 데이터를 신뢰할 수 있었다.

예인수조용 스테레오스코픽 입자영상유속계 시스템의 불확실성 해석 (Uncertainty Assessment of a Towed Underwater Stereoscopic PIV System)

  • 서정화;설동명;한범우;유극상;임태구;박성택;이신형
    • 대한조선학회논문집
    • /
    • 제51권4호
    • /
    • pp.311-320
    • /
    • 2014
  • Test uncertainty of a towed underwater Stereoscopic Particle Image Velocimetry (SPIV) system was assessed in a towing tank. To estimate the systematic error and random error of mean velocity and turbulence properties measurement, velocity field of uniform flow was measured. Total uncertainty of the axial component of mean velocity was 1.45% of the uniform flow speed and total uncertainty of turbulence properties was 3.03%. Besides, variation of particle displacement was applied to identify the change of error distribution. In results for variation of particle displacement, the error rapidly increases with particle movement under one pixel. In addition, a nominal wake of a model ship was measured and compared with existing experimental data by five-hole Pitot tubes, Pitot-static tube, and hot wire anemometer. For mean velocity, small local vortex was identified with high spatial resolution of SPIV, but has serious disagreement in local maxima of turbulence properties due to limited sampling rate.

Canine brucellosis 검출을 위한 ELISA 진단법 확립 (Development of ELISA for detection of canine brucellosis)

  • 허진;백병걸
    • 한국동물위생학회지
    • /
    • 제34권2호
    • /
    • pp.159-166
    • /
    • 2011
  • This study was carried out to develope enzyme-linked immunosorbent assay (ELISA) for detection of canine brucellosis in dogs experimentally inoculated with Brucella abortus 1119-3 and B. canis RM666. Groups A, B and C of dogs (each group consisting of three dogs) were orally inoculated with approximately $5{\times}10^9$ colony-forming units of B. abortus and B. canis, and with sterile pyrogen-free PBS, respectively. The animals were monitored at regular intervals upto the 12th week post inoculation (PI) by standard tube agglutination test (STAT), plate agglutination test (PAT), Rose Bengal test (RBT), 2-mercaptoethanol rapid slide agglutination test (2ME-RSAT) and ELISA. The induced antibody titers in group A dogs were detected from the first week PI to the eighth week PI in STAT, PAT and RBT using the inactivated whole cells of B. abortus 1119-3 as antigens, while no sera in groups B and C dogs reacted with the antigens. In 2ME-RSAT using whole cells of B. canis M-strain as antigens, the induced antibody titers in group B dogs were observed at the second week PI and persisted for the 12th week PI, while sera of groups A and C dogs did not react with the whole cells. In ELISA using cytoplasmic fractions antigen of B. abortus 1119-3, the mean optical density of antibodies in groups A and B was detected from the first and second weeks PI, respectively, and persisted for 12th week PI, while sera of group C did not cross-react with the fractions antigen. However, in ELISA using the hot saline extracts of B. canis M- as an antigen, the induced antibody titers in only group B dogs were detected from second week PI and persisted for until the end of this study. These results indicate that the ELISA using B. abortus 1119-3 cytoplasmic fractions as antigens can be a good candidate for detection of brucellosis by B. abortus as well as B. canis in dogs.