• 제목/요약/키워드: hot-box test

검색결과 29건 처리시간 0.035초

포르말린 및 열성 자극 유발 통증에 대한 척수강 Melatonin의 항침해 효과 (Antinociceptive Effects of Intrathecal Melatonin on Formalin- and Thermal-induced Pain in Rats)

  • 정성태;진원종;배홍범;김석재;최정일;강명우;정창영;윤명하
    • The Korean Journal of Pain
    • /
    • 제19권2호
    • /
    • pp.137-141
    • /
    • 2006
  • Background: It has been known that melatonin is involved in the modulation of nociceptive transmission. However, the effect of melatonin administered spinally has not been examined. Therefore, we examined the effect of melatonin on the formalin-induced or thermal-induced nociception at the spinal level. Methods: Intrathecal catheter was inserted into the subarachnoid space of male Sprague-Dawley rats. Pain was assessed by formalin test (induced by injection of $50{\mu}l$ of a 5% formalin solution to the hindpaw) or Hot-Box test (induced by radiant heat application to the hindpaw). The effect of intrathecal melatonin was examined on flinching behavior in the formalin test or withdrawal response in Hot-Box test. Results: Intrathecal melatonin produced a limited, but dose-dependent reduction of the flinching response during phase 1 and 2 in the formalin test. In addition, melatonin delivered at evening also decreased the flinching response in both phases of the formalin test. Melatonin restrictively increased the withdrawal latency in Hot-Box test. Conclusions: These results suggest that melatonin is active against the formalin- and thermal-induced nocicpetion at the spinal level, but the effect is limited.

온실용 다겹보온자재의 보온성 비교 -Hot box 시험 결과를 중심으로- (Comparison of Thermal Insulation of Multi-Layer Thermal Screens for Greenhouse: Results of Hot-Box Test)

  • 윤성욱;이시영;강동현;손진관;박민정;김희태;최덕규
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.255-264
    • /
    • 2019
  • 본 연구에서는 현장 온실농가에서 수명이 다하여 교체작업이 이루어진 총 4종의 다겹보온자재를 채취하여 해당 사용기간별 보온성의 변화를 비교하기 위해 여기서 고안된 Hot box 시험이 실시되었다. 4종의 다겹보온자재는 마트지, 부직포, PE폼 및 화학솜 등이 주요 재료로서 다겹보온자재별로 이 재료들이 서로 다르게 조합된 형태였다. 이 4종의 다겹보온자재를 시편($70{\times}70cm$)으로 제작하여 Hot box 시험을 통해서 대상시편별로 온도 하강률, 열관류율 및 열전도저항 등이 측정되었다. 그 결과를 요약하면 다음과 같다. 본 연구에서 사용된 다겹보온자재들에 대하여 적절한 보온성능을 기대할 수 있는 사용기간은 약 5년 정도로 예상되었다. 다겹보온자재의 재료조합에 대하여 다겹의 PE폼을 적용하여 상대적으로 보온성을 높일 수 있으나 다겹보온자재 내에서 공기 단열층을 형성하는 화학솜에 비해 보온성능에 대한 기여가 현저히 낮은 것으로 판단되었다. 다겹보온자재에 대하여 적절한 보온성능을 기대하기 위해서는 기본적으로 화학솜과 같은 공기 단열층을 형성하는 기능이 있는 재료가 다겹보온자재에 포함되어야 될 것으로 판단되었다. 본 연구에서 고안된 Hot box 시험을 통해 다겹보온 자재의 온도 하강률, 열관류율 및 열전도저항 등이 적절하게 측정되었다. 그러나 본 연구는 사용이 완료된 다겹보온자재의 채취 어려움으로 총 4종의 다겹보온자재만 고려되었으며, 이는 비교적 적은 사례로 통해 얻어진 결과라 할 수 있으며, 본 연구의 한계이다. 향후 관련 연구를 통해 더 많은 사례들이 조사 및 보완되어야 될 것이다.

2 모듈 스택을 이용한 SOFC 시스템 운전결과 (Operation Results of the SOFC System Using 2 Sub-Module Stacks)

  • 이태희
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

Fatigue Strength and Root-Deck Crack Propagation for U-Rib to Deck Welded Joint in Steel Box Girder

  • Zhiyuan, YuanZhou;Bohai, Ji;Di, Li;Zhongqiu, Fu
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1589-1597
    • /
    • 2018
  • Fatigue tests and numerical analysis were carried out to evaluate the fatigue performance at the U-rib to deck welded joint in steel box girder. Twenty specimens were tested corresponding to different penetration rates (80 and 100%) under fatigue bending load, and the fatigue strength was investigated based on hot spot stress (HSS) method. The detailed stress distribution at U-rib to deck welded joint was analyzed by the finite element method, as well as the stress intensity factor of weld root. The test results show that the specimens with fully penetration rate have longer crack propagation life due to the welding geometry, resulting in higher fatigue failure strength. The classification of FAT-90 is reasonable for evaluating fatigue strength by HSS method. The penetration rate has effect on crack propagation angle near the surface, and the 1-mm stress below weld toe and root approves to be more suitable for fatigue stress assessment, because of its high sensitivity to weld geometry than HSS.

고속철도 귀선전류 및 차축 온도 검측을 위한 검측장치 구현 (Implementation of the Measurement Equipment to Measure Return Current and Axle Temperature of High Speed Railway)

  • 이영수;이병곤;황인광;한승훈
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.695-703
    • /
    • 2016
  • The maintenance method for the electrical facility of high speed railway has been evolved from inspection by personnel to the automated way by the detection devices. In particular, the signalling equipment in order to increase the safe and efficient operation of the trains is required to maintain normal operation by periodic maintenance. Because the return current gives the most important effects to the wayside equipment in case of the failures, a method is needed to measure the unbalanced rate of return current on the train at high speed driving. The Hot Box Detector(HBD) device that is installed at track-side has a function to recognize the abnormal axle box by detecting the temperature that occurs in the axle of train passing over its device. In order to implement the measurement equipment for unbalanced rate of return current and axle temperature, the design method is proposed and the experimental test results by test bed are included in the paper.

HR Coil재 Box형 용접구조물의 피로강도평가에 관한 연구 (Fatigue Strength Evaluation of Welded Box Type with HR Coil)

  • 강성원;김명현;장용원;이진우
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.20-24
    • /
    • 2005
  • Due to the difficulties associated with the supply of steel plates, hot rolled coil (Steel grade: SM490A) is considered fur structural materials in replace of the existing SWS50A-M1. However, it is found that SM490A exhibits a significant anisotropy in terms of impact energy with respect to transverse and longitudinal directions. In this study, an experimental investigation is carried out to examine the relationship between the anisotropy in impact values and the fatigue strengths of SM490A with respect to the rolling direction of test specimens. All test specimens failed around 1,500,000 cycles regardless of the test specimen direction. Therefore, it is found that the anisotropy in impact energy is not related to the fatigue strength of the materials considered in this study. However, the transverse direction specimen showed more rapid brittle fracture mode compared to that of longitudinal direction specimen, and this appears to be related to the lower impact values in transverse direction.

SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험 (Development and Performance Test of SOFC Co-generation System for RPG)

  • 이태희;최진혁;박태성;최호윤;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Optimization of arc brazing process parameters for exhaust system parts using box-behnken design of experiment

  • Kim, Yong;Park, Pyeong-Won;Park, Ki-Young;Ryu, Jin-Chul
    • Journal of Welding and Joining
    • /
    • 제33권2호
    • /
    • pp.23-31
    • /
    • 2015
  • Stainless steel is used in automobile muffler and exhaust systems. However, in comparison with other steels it has a high thermal expansion rate and low thermal conductivity, and undergoes excessive thermal deformation after welding. To address this problem, we evaluated the use of arc brazing in place of welding for the processing of an exhaust system, and investigated the parameters that affect the joint characteristics. Muffler parts STS439 and hot-dipped Al coated steel were used as test specimens, and CuAl brazing wire was used as the filler metal for the cold metal transfer (CMT) welding machine, which is a low heat input arc welder. In addition, a Box-Behnken design of experiment was used, which is a response surface methodology. The main process parameters (current, speed, and torch angle) were used to determine the appropriate welding quality and the mechanical properties of the brazing part was evaluated at the optimal welding condition. The optimal processing condition for arc brazing was 135A current, 51cm/min speed and $74^{\circ}$ torch angle. The process was applied to an actual exhaust system muffler and the prototype was validated by thermal fatigue, thermal shock, and endurance limit tests.

게인 스케쥴링과 캐스케이드 제어에 의한 가상현실용 열환경의 실시간 구현 (Implementation of Real-Time Thermal Environment for Virtual Reality Using Gain Scheduling and Cascade Control)

  • 신영기;장영수;김영일
    • 제어로봇시스템학회논문지
    • /
    • 제7권7호
    • /
    • pp.567-573
    • /
    • 2001
  • A real-time HVAC system is proposed which implements real-time control of thermal environment for virtual reality. It consists of a pair of hot and cold loops that serve as thermal reservoirs, and a mixing box to mix hot and cold air streams flowing if from loops. Their flow rates are controlled in real-time to meet a set temperature and flow rate. A cascade control algorithm along with gain scheduling is applied to the system and test results shows that the closed-loop response approached set values within 3 to 4 seconds.

  • PDF

BATCH형 자연형 태양열 온수급탕 시스템의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Batch Type Passive Solar Hot Water System)

  • 강용혁;조일식;윤환기;오정무
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.3-13
    • /
    • 1987
  • A batch type passive solar water systems, which perform the dual function of absorbing the solar energy and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing at KIER. The test models included an A, B and C type batch systems which were classified according to the design of box and arrangement of tanks. The year-round performance tests show that B type batch system taken the step-wise tank arrangement indicates 55.7% yearly-average collection efficiency factor and 61% yearly-average maximum collection efficiency factor. Computer-aided-experimental results show that the sufficient hot water can be obtained in the early morning if the glazing is supplemented by a reflector/insulation cover. The thermal performance equation has been developed for the prediction of hourly variation of the water temperature in tank.

  • PDF