• Title/Summary/Keyword: hot video

Search Result 33, Processing Time 0.034 seconds

Design and Evaluation of a Channel Reservation Batch-Patching Technique for VOD Services (VOD 서비스를 위한 채널 예약 배치-패칭 방법의 설계 및 평가)

  • 하숙정;이경숙;배인한
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.3
    • /
    • pp.357-367
    • /
    • 2004
  • In VOD systems the number of channels available to a video server is limited since the number of channels, the video server can support, is determined by the communication bandwidth of the video server. Multicast techniques such as batching, patching and batch-patching have been proposed to reduce I/O demand on the video server by sharing multicast data. In this paper, we propose a channel reservation batch-patching technique that first applies the batching technique to hot video requests and then applies the patching technique to the batches of the hot video requests. And the proposed technique reserves a part of the channel capacity of the video server for many hot video requests, so that the hot video requests can be served without defection. The performance of the proposed technique is compared with those of Patching and Batch-Patching techniques in terms of average service latency, defection rate, fairness and frame reduction rate by simulations.

  • PDF

Quality Adaptation of Intra-only Coded Video Transmission over Wireless Networks

  • Shu Tang;Yuanhong Deng;Peng Yang
    • Journal of Information Processing Systems
    • /
    • v.19 no.6
    • /
    • pp.817-829
    • /
    • 2023
  • Variable wireless channel is a big challenge for real-time video applications, and the rate adaptation of realtime video streaming becomes a hot topic. Intra-video coding is important for high-quality video communication and industrial video applications. In this paper, we proposed a novel adaptive scheme for real-time video transmission with intra-only coding over a wireless network. The key idea of this scheme is to estimate the instantaneous remaining capacity of the network to adjust the quality of the next several video frames, which not only can keep low queuing delay and ensure video quality, but also can respond to bandwidth changes quickly. We compare our scheme with three different schemes in the video transmission system. The experimental results show that our scheme has higher bandwidth utilization and faster bandwidth change response, while maintaining low queuing delay.

Multi-view video coding (다시점 비디오 코딩)

  • Park, Sea-Nae;Sim, Dong-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.57-60
    • /
    • 2008
  • In this paper, we describe the technology about multiview video coding which is a hot issue in diqital video coding. A multiview video coding (MVC) is able to provide a free view point and 3-D effect, resulting that it gives more realism to users. Now, the MVC has been standardized as an amendment of H.264/AVC. In this paper, we present not only the MVC standard but also relevant techniques which were under consideration in the MVC standardization.

  • PDF

Variable-bit-rate compressed video storage and placement scheme for arbitrary-speed retrievals (임의 속도 탐색을 위한 가변 비트율 압축 비디오 데이타의 저장 및 배치기법)

  • 권택근;이석호;최양희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.8
    • /
    • pp.15-21
    • /
    • 1996
  • This paper describes data placement schemes that provide uniform and balanced to multiple disks load for retrievals of VBR (variable bit rate) video at varying retrieval speeds. To support maximum concurent users at arbitrary-speed playbacks in a disk-arry based system, the hot spot disks should be carefully avoided. In this paper, we extend the proposed scheme, prime round-robin(PRR), for VBR video. In addition, we have compared the performance of PRR and PRR (PRR extension).

  • PDF

HOT-SMOKE TESTS IN TWO UNDERGROUND RAILWAY STATIONS WITH MOVING TRAINS

  • Allan, Hugh
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.472-476
    • /
    • 1997
  • Hot-smoke testing in Australia has progressed to the stage where there is an Australian Standard for these tests. The purpose of such tests is twofold: firstly they can validate computer modeling predictions for smoke movement, and secondly they can demonstrate that the smoke control systems and associated fire safety systems function satisfactorily. Hot-smoke tests were carried out in March 1997 at two of Sydney's underground railway stations, namely St James and Museum. The purpose of the tests was to demonstrate that the smoke control systems performed their functions as intended. Tests were carried out in the concourses and on the platforms, and trains ran during the tests so that the effect of moving trains on smoke movement could be observed. A total of five tests were carried out and video recordings were taken of each. This is the first time that hot-smoke tests have been carried out in an underground station with trains running. The paper discusses some of the interesting observations and the problems identified by the tests.

  • PDF

Measurement of Flow Field in a Domestic Hot-Water Pump by PIV (PIV에 의한 가정용 온수펌프의 유동장 계측)

  • Lee, H.;Im, Y. C.;Kim, J. H.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

A Study on the Evaporation and Ignition of Single Fuel Droplet on the Hot Surface (고온벽면에서의 액적연료의 증발 및 착화에 관한 연구)

  • 송규근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.132-137
    • /
    • 2002
  • Recently, impinging spray is used for atomization of diesel engine, but it bring on adhesion of fuel. Therefore, we studied about droplet behavior on high temperature plate changing the size of droplet, surface temperatures, and surface roughness of plate. In this study, We studied to confirm experimentally about mechanism of evaporation and ignition process of single fuel droplet. We observed evaporation time, evaporation appearance and ignition delay time by the photopraphs of 8mm video camera. Experimental results are summarized as follows: 1. The boiling point of fuel affect a evaporation and ignition process. 2. The surface roughness affect a evaporation time. 3. The ignition delay time relate to evaporation characteristic.

Evaporation Cooling Phenomena of Droplets Containing Fire Suppression Agents (화제 억제제가 첨가된 수용액 액적의 증발냉각 현상)

  • 유갑종;방창훈;김현우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.895-903
    • /
    • 2001
  • Evaporation cooling phenomena of droplets containing fire suppression agents on a hot metal surface were experimentally investigated. Solution of water containing potassium acetate (30-50% by weight) and sodium bromide (10-30% by weight) were used in the experiments, and surface temperatures were ranged from 70-116$^{\circ}C$. The evaporation time of the droplet on the heated surface was determined by using frame-by-frame analysis of the video records. It is found that the apparent evaporation time is shorter in turns of pure water, sodium bromide solution and potassium acetate solution. However, the time averaged heat flux is higher in turns of pure water, sodium bromide solution and potassium acetate solution. In-depth temperature variation of the hot metal does not occur significantly by the kinds of additive.

  • PDF

An Experimental Study on the Cooling of Unburned Surface due to Water Droplet (물액적에 의한 미연소면의 냉각에 관한 실험적 연구)

  • 방창훈;김정수;예용택
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.13-18
    • /
    • 2000
  • The objective of the present work is to examine the cooling characteristics of water droplet on the unburned surface. The hot solid surface material used brass, carbon steel and copper at temperature ranging from 70 to $116^{\circ}$. the droplet size is from 2.4 mm to 3.0 mm. The CCD camera was used to record the evaporation histories of the droplets. and the evaporation time of the droplet on the hot solid surface could be determined by using frame-by-frame analysis of the video records. It is found that during the droplet evaporation process for copper the temperature remains nearly constant, whereas for carbon steel the temperature continuously decreases about $1^{\circ}$. During the droplet evaporation process on the hot solid surface, regardless of solid materials, nondimensional droplet volume decreases nondimensional evaporation time increases.

  • PDF

Cache Optimization on Hot-Point Proxy Caching Using Weighted-Rank Cache Replacement Policy

  • Ponnusamy, S.P.;Karthikeyan, E.
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.687-696
    • /
    • 2013
  • The development of proxy caching is essential in the area of video-on-demand (VoD) to meet users' expectations. VoD requires high bandwidth and creates high traffic due to the nature of media. Many researchers have developed proxy caching models to reduce bandwidth consumption and traffic. Proxy caching keeps part of a media object to meet the viewing expectations of users without delay and provides interactive playback. If the caching is done continuously, the entire cache space will be exhausted at one stage. Hence, the proxy server must apply cache replacement policies to replace existing objects and allocate the cache space for the incoming objects. Researchers have developed many cache replacement policies by considering several parameters, such as recency, access frequency, cost of retrieval, and size of the object. In this paper, the Weighted-Rank Cache replacement Policy (WRCP) is proposed. This policy uses such parameters as access frequency, aging, and mean access gap ratio and such functions as size and cost of retrieval. The WRCP applies our previously developed proxy caching model, Hot-Point Proxy, at four levels of replacement, depending on the cache requirement. Simulation results show that the WRCP outperforms our earlier model, the Dual Cache Replacement Policy.