• 제목/요약/키워드: hot thermocouple method

검색결과 8건 처리시간 0.03초

쾌속 열용삭 공정에서 열반경 최소화를 위한 열 공구 설계에 관한 연구 (A Study of Design for Hot Tool to Minimize Radius of Heat Affected Zone in Rapid Heat Ablation process)

  • 김효찬;이상호;박승교;양동열
    • 한국정밀공학회지
    • /
    • 제23권7호
    • /
    • pp.177-186
    • /
    • 2006
  • In order to realize a three-dimensional shape on CAD, the machining process has been widely used because it offers practical advantages such as precision and versatility. However, the traditional machining process needs a large amount of time in cutting a product and the remained material causes trouble such as inconvenience due to cleaning process. Therefore, a new rapid manufacturing process, Rapid Heat Ablation process (RHA) using the hot tool, has been developed. In this paper, the hot tool for RHA process is designed to minimize radius of heat affected zone. TRIZ well-known as creative problem solving method is applied to overcome the contradictive requirements of the hot tool. For the detailed design of the hot tool, numerical model is established with several assumptions. In order to verify the numerical results, surface temperature of the hot tool is measured with K-type thermocouple at the predetermined location. Numerical and experimental results show that the devised hot tool fulfils its requirements. The practicality and effectiveness of the designed hot tool have been verified through experiments.

적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가 (Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test)

  • 윤석태
    • 한국산업정보학회논문지
    • /
    • 제28권6호
    • /
    • pp.21-27
    • /
    • 2023
  • 현대 함정은 외부로 방사되는 적외선 신호를 낮추기 위해 폐기관에 적외선 신호저감 장치(Infra-Red Signature Suppression system, IRSS)를 설치한다. 그리고 함정은 생의 주기가 매우 긴 전략 자산으로 탑재 장비들의 성능에 대한 높은 신뢰성을 충분히 확보해야 한다. 따라서, IRSS와 같은 장비들은 설계 단계에서 모형시험을 통해 성능평가를 하고 있다. IRSS의 모형시험에서는 다양한 계측기기들이 사용된다. 그러므로, 모형시험 단계 이전에 계측기들의 신뢰성을 평가해야 한다. 본 연구에서는 IRSS 모형시험에 사용되는 계측 장비들의 신뢰성 평가에 관한 연구를 수행하였다. 시험 장비와 계측기는 열 풍동 시험기, 피토 튜브와 디지털 차압계, 열전대 센서 그리고 디지털 기록계가 사용되었다. 계측 결과 열 풍동 시험기의 풍속이 증가할수록 유동의 계측 편차가 감소하였으며, 열전대 센서의 온도는 사용 방법에 따라 반응 속도 및 민감도의 차이를 보였다.

쾌속 열용삭 공정에서 열반경 최소화를 위한 열 공구 설계에 관한 연구 (A Study of Design for Hot Tool to Minimize Radius of Heat Affected Zone in Rapid Heat Ablation process)

  • 김효찬;이상호;송민섭;양동열;박승교
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.743-748
    • /
    • 2005
  • In order to realize a three-dimensional shape on CAD, the machining process has been widely used because it offers practical advantages such as precision and versatility. However, the traditional machining process needs a large amount of time in cutting a product and the remained material causes trouble such as inconvenience for clarity. Therefore, a new rapid manufacturing process using the hot tool, Rapid Heat Ablation process (RHA), has been developed. In this paper, the hot tool for RHA process is devised to minimize radius of heat affected zone and also investigated for verification. TRIZ well-known as creative problem solving method is applied to overcome the contradictive requirements of the hot tool. For the detailed design of the hot tool, numerical model is established with several assumptions. Based on the numerical results, surface temperature is measured with K-type thermocouple at the predetermined location. Numerical and experimental results show that the devised hot tool fulfils its requirements. It verifies the practicality of hot tool that the hemisphere shape is ablated using the hot tool with stair structure.

  • PDF

자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰 (In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.172-180
    • /
    • 2003
  • 본 연구에서는 자기공명영상(MRI)에서 수소 원자핵의 공명주파수(PRF) 방법을 기반으로 인체 종아리 근육 외부의 열원에 의해 근육 내부로 열원이 전달되는 과정을 비침습적으로 관찰하는 방법을 제시한다. 열전달과정을 온도 변화로 측정하였는데 온도 영상의 안정성 및 보정 실험은 phantom을 이용하였고 온도의 변화는 phantom과 인체 모두에서 측정하였다. Phantom 실험은 agarose gel을 중탕하여 약 50℃까지 가열시킨 후 1시간의 냉각과정 동안 매 3분마다 데이터를 획득하였다. 인체 실험에서는 지원자의 종아리(the calf)에 hot pack을 이용하여 열을 전달하였다. Hot pack을 발열시키기 전에 기준 데이터를 1번 획득하고, 발열시킨 후부터 매 2분마다 30분 동안 데이터를 획득하였다. 획득된 영상 데이터는 위상차 영상으로 재구성된 다음 각 ROI에서의 평균 위상차를 관측하였다. 온도를 34.2∼50.2℃의 범위에서 변화시켰을 때 phantom의 위상차는 온도 변화에 대해 선형적으로 변하였다. 이 범위에서 측정된 온도의 해상도는 0.0457 radian/℃(0.0038 ppm/℃)였다. 인체 실험에서는 각 영상에서 hot pack과 가까운 위치의 평균 위상차가 hot pack과 먼 위치의 평균 위상차보다 작은 값을 나타냈다 이를 통해 같은 영상 단면에서도 열원(heat source)과의 거리에 따라서 온도 변화가 다르게 나타나는 것을 관찰할 수 있었다. 본 연구를 통해 PRF방법을 이용하여 MRI에서도 비침습적으로 인체 내부의 열전달과정을 관측하였고 이로서 온열치료 시 MRI가 임상적 이용 가능성이 있음을 확인하였다.

Direct Observation on Pyrolysis of Some Plastics

  • Takasu, Tomio;Itou, Hideyuki;Shibata, Etsuro;Kasai, Eiki;Nakamura, Takashi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.742-745
    • /
    • 2001
  • Plastics are one of difficult materials for recycling due to their characteristics in use. Recycling ratio of waste plastics was around 40% in last year in Japan, which includes energy recovery. Feed stock recycling and mechanical recycling are not easy because of additives in commercial plastics. Then, pyrolysis treatments have been done to recovery energy. Although plastics are easy to fire, complete combustion of them is not easy if anti-firing agents are added especially. Therefore, researches on pyrolysis or combustion behaviors of plastics containing additives are important from a view point recycling of plastics. Direct observation of popular plastics like polystyrene (PS), polycarbonate (PC), polyphenyle ether (PPE) and polyvinyl chloride (PVC) to investigate their pyrolysis behaviors in the present study. In case of PS, melting and gas evolution started at 9$0^{\circ}C$ and 39$0^{\circ}C$ respectively. And combustion finished at 445$^{\circ}C$. On the other hand, more than $600^{\circ}C$ and sufficient oxygen are required for complete combustion of PC and PPE.

  • PDF

Measurement of the Thermal Conductivity of a Polycrystalline Diamond Thin Film via Light Source Thermal Analysis

  • Kim, Hojun;Kim, Daeyoon;Lee, Nagyeong;Lee, Yurim;Kim, Kwangbae;Song, Ohsung
    • 한국재료학회지
    • /
    • 제31권12호
    • /
    • pp.665-671
    • /
    • 2021
  • A 1.8 ㎛ thick polycrystalline diamond (PCD) thin film layer is prepared on a Si(100) substrate using hot-filament chemical vapor deposition. Thereafter, its thermal conductivity is measured using the conventional laser flash analysis (LFA) method, a LaserPIT-M2 instrument, and the newly proposed light source thermal analysis (LSTA) method. The LSTA method measures the thermal conductivity of the prepared PCD thin film layer using an ultraviolet (UV) lamp with a wavelength of 395 nm as the heat source and a thermocouple installed at a specific distance. In addition, the microstructure and quality of the prepared PCD thin films are evaluated using an optical microscope, a field emission scanning electron microscope, and a micro-Raman spectroscope. The LFA, LaserPIT-M2, and LSTA determine the thermal conductivities of the PCD thin films, which are 1.7, 1430, and 213.43 W/(m·K), respectively, indicating that the LFA method and LaserPIT-M2 are prone to errors. Considering the grain size of PCD, we conclude that the LSTA method is the most reliable one for determining the thermal conductivity of the fabricated PCD thin film layers. Therefore, the proposed LSTA method presents significant potential for the accurate and reliable measurement of the thermal conductivity of PCD thin films.

평면형 다중접합 열전변환기의 제작 (Fabrication of Planar Multi-junction Thermal Converter)

  • 권성원;박세일;조용명;강전홍
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.17-24
    • /
    • 1996
  • 교류-직류 변환방법으로 교류전압 및 전류를 정밀측정하기 위한 평면형 다중접합 열전변환기를 제작하였다. 실리콘 기판에 지지된 $Si_{3}N_{4}$ (200 nm) / $SiO_{2}$ (400 nm) / $Si_{3}N_{4}$ (200 nm) 샌드위치구조의 두께 $0.8\;{\mu}m$ (크기 $2{\times}4\;mm^{2}$)의 멤브레인 위에 가열선과 열전대 접합을 형성하였다. 멤브레인의 세로방향 중앙에 NiCr 가열선을 배치하고, 가열선 주위 또는 그 위에 동-콘스탄탄(Cu- CuNi44)으로 $48{\sim}156$ 개의 열전대의 열(熱)접합을 형성하였으며, 열전대의 냉(冷)접합은 실리콘 기판 위에 형성하였다. 직류 10 mA의 입력에 대한 열전대의 출력전압은 종류에 따라 $76\;mV{\sim}382\;mV$를 얻었으며, 입력 5 mA일때 출력전압의 단기안정도는 ${\pm}5{\sim}15\;ppm4/ 10 min이었다. 공기분위기에서 감응도는 $3.9{\sim}14.5V/W$로 측정되었고, 열전대의 수가 48개인 모델 BF48의 경우 공기중에서의 감응도가 3.9 V/W로써, 56개의 열전대를 갖는 3차원구조 다중접합 열전변환기의 진공분위기에서의 감응도보다 2배 이상 크게 나타났다. 또한 측정전류 10 mA 이하, 측정주파수 $5\;Hz{\sim}2\;kHz$에서의 교류-직류 변환차이는 약 ${\pm}1\;ppm$ 이하이었고, 5 kHz 및 10 kHz에서는 약 $2{\sim}3\;ppm$ 이었다.

  • PDF

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF