• Title/Summary/Keyword: hospital uniform

Search Result 144, Processing Time 0.025 seconds

Evaluation of Anti-Inflammatory Effect of Pulsed Electromagnetic Field on DNCB-Induced Atopic Dermatitis Using Principal Component Analysis (주성분 분석을 이용한 펄스형 전자기장 자극을 통해 DNCB로 유발된 아토피성 피부염의 개선 효과 분석)

  • Lee, Jiyoung;Kim, Jun-Yong;Lee, Yerin;Kim, Ko Eun;Lee, Yongheum;Yang, Sejung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.94-99
    • /
    • 2021
  • Atopic dermatitis (AD), a chronic inflammatory skin disease, is characterized by itchy and age-dependent lesions. Previous studies have shown that pulsed electromagnetic field (PEMF) significantly improved chronic ulcers and ununited fractures, providing an evidence for the application of PEMF in resolving inflammation caused by AD. This study investigated the anti-inflammatory effect of PEMF on DNCB-induced AD in animal models. Five male hairless mice (6 weeks old) per group were assigned to a normal group, a sham group, and two PEMF groups (15Hz, 75Hz). Mice were treated with 2,4-Dinitrochlorobenzene (DNCB) to induce uniform AD among all groups excluding a normal group. To examine the inflammatory progress and the improvement of AD after the PEMF stimulation, images are taken with various cameras for non-invasive evaluation and the results are expressed using principal component analysis (PCA) for visualization. The results of this study demonstrated that PEMF effectively improved skin lesions without the use of drugs.

Fecal Microbiota Transplantation via Commercial Oral Capsules for Chronic Enteropathies in Dogs and Cats

  • Min-Ok Ryu;Soh-Yeon Lee;Se-Hoon Kim;Hwa-Young Youn;Kyoung-Won Seo
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.150-156
    • /
    • 2024
  • This retrospective case series assessed the effectiveness of commercially available oral fecal microbiota transplantation (FMT) for treating chronic enteropathies in eight animals, five dogs, and three cats, between 2020 and 2023 at the Seoul National University Veterinary Medical Teaching Hospital. Chronic enteropathies, often resistant to conventional therapies, present a significant challenge in veterinary medicine. To assess oral capsule FMT's effectiveness (Doggybiome® one capsule daily for dogs and Kittybiome® one capsule daily for cats) as a universal adjunctive therapy for chronic enteropathies across species not responding to traditional treatments. This retrospective case series applied a uniform evaluation of gastrointestinal symptoms and treatment efficacy, utilizing established scoring systems (Canine Inflammatory Bowel Disease Activity Index [CIBDAI] and Canine Chronic Enteropathy Clinical Activity Index [CCECAI] for dogs, Feline Chronic Enteropathy Activity Index [FCEAI] for cats) before and one month after FMT. This approach ensured consistency in hypothesis testing across the study population. Results revealed significant improvements in clinical indices post-FMT, with notable reductions in the CIBDAI, CCECAI, and FCEAI scores (p < 0.05). Additionally, symptoms such as anorexia, lethargy, diarrhea, vomiting, and weight loss showed marked improvement, with normalization of appetite and activity levels observed in most cases. No adverse effects were reported, indicating the safety and tolerability of this treatment. This study highlights the potential of oral capsule FMT as a viable therapeutic option for dogs and cats with chronic enteropathies unresponsive to conventional treatments, providing a new avenue for clinical management. Further research is warranted to expand these findings and explore the microbiome changes associated with FMT in veterinary patients.

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

Study on Relationship Between Intima Medial Thickness and the Plaque in Stroke Patients on Carotid Artery Sonography (뇌경색 환자에서 초음파로 측정한 경동맥 내막-중막두께와 죽상경화반의 관련성에 대한 연구)

  • Lee, Mi-Hwa;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • The carotid intima-media thickness (IMT) is an early structural marker of the atherosclerotic process and is the only non-invasive test that is currently recommended by the American Heart Association for evaluation of the risk. However, use of this parameter has a limitation because it assumes uniform thickness throughout the blood vessel, whereas atherosclerosis is a focal phenomenon that is confined to intima. In fact, plaque can be found along the atherosclerotic blood vessels even though its value is unknown. The aim of this study is to analyze the carotid plaque and IMT in the stroke patients. We investigated the patients with ischemic stroke, who were admitted to the department of neurology at the Stroke Special Hospital from January to March 2008. After the carotid IMT and plaque were assessed by B-mode ultrasonography, IMT and carotid plaque to risk variables (age, sex) were analyzed. The distribution of CCA IMT was significantly different in terms of age (p = 0.004). Likewise, the distribution of carotid plaque was also significantly different in terms of age (p = 0.006). Carotid plaque was 69 and 92% in normal and abnormal CCA IMTs respectively. The results showed that the CCA IMT was closely associated with carotid plaque.

  • PDF

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF

An Analysis of Nursing Behavior and Unit of Treatment Cost of Non- Insurance Patients (종합병원의 비보험환자 처치행위 양상과 수가분석에 관한 연구)

  • 오세영
    • Journal of Korean Academy of Nursing
    • /
    • v.10 no.1
    • /
    • pp.41-55
    • /
    • 1980
  • The medical care insurance system, being put into practice nearly for three years, seem to have brought about some considerable problems as serious for the government as to consider a revision of that system. As one of the most serious problems of present system, the treatment cost of insurance patients is so remarkably low in comparison with than of non-insurance cases that normal operation of hospitals is threatened and care services of low quality are induced. The researcher carried out this survey to analyze and bring to light several aspects of treatment cost of non-insurance patients as a material for a re-assessment of the cost of insurance cases which shows a a considerable difference in amount at the standpoint of hospitals with than of non-insurance cases and further, hoping the significant blind spot of present insurance system(that is, the absence of regulations' for cost assessment by patterns or types of health care treatment) will be mended in near future. The survey was carried out with the treatment invoice sheets of total 902 in-hospital Patients of a general hospital in Seoul during the period of the 2 nd quarter of the year(1979). Among total 902 patients, 694 cases were used for analysis, because those disease or syndromes shared by less than 10% of the patients were put aside before procession. The data were analyzed by kinds or types of diseases, demographic characteristics of patients, hospitalization patterns, types of nursing treatment, etc. The result of analysis was as follows 1. Among all the non-insurance cases, those who received one or more kinds of nursing treatment mounted up to 96. 7 %. The invoice issue frequency per person was 7.2 times, while that frequency per day for a person was 0.8, : the treatment cosr per person was ₩22,650 while its daily average was ₩2,430, due to the average 9.3 in-hospital days per person. 2. As to the nursing treatment types by the demographic characteristics of patients and hospitalization patterns. a. The unit cost female patients was generally more expensive them that of males, and independent nursing service was more given than other types of treatment. As to age, higher age groups received independent nursing service most, while the youngest group received instrumental and integrated nursing services. b. As to room grade, the unit cost of I.C.U. cases was the highest : and the cast of private room patients was higher than that of public room patients. By in-hospital days, the curve of function showed L. type : that is, the longer stay, the lower function. 3. State of treatment types by kinds of disease were ; a. Dependent nursing service showed comparatively high availability in surgical and neurologic disease and independent nursing service was most received by medical, obstetrical and urological patients, while instrumental and integrated services were most available for respiratory disease and obstetrical and neurologic diseases next. b. The invoice issue frequency per day for a patient was highest in obstetrical disease 3.8 times, and the unit cost(per one invoice sheet) was also highest in obstertrical disease(₩10,880) and next in neurologic cases(₩ 4,690 ). 4. As to the pertained departments. a. Cost amount per person was highest in department of Psychiatries daily cost was highest in obstetrical cases : while the invoice issue frequency was highest in obstetrics and next in pediatrics. b. In departments in need of surgical operation, dependent nursing care was highly availabl : while in internal medicine and obstetrics, independent service was higher. Psychiatrics showed the highest the of integrate nursing while pediatrics and obstetrics higher of instrumental services. The variation co-efficien of treatment cost came out to be relatively in high in special surgery, opthalmology and internal medicine. 5. State of treatment cost by types of nursing behavior was. a. The average frequency of invoice issue was 3.5 (times). Among the type four types of treatment, instrumetal service (4.3) and independent nursing behavior(3.9) showed higher frequency than average respectively. But as to unit cost (per invoice). dependent (₩5,200) and integrated (₩5,340) nursing care services were higher than average and considerably higher than the other two types. b. In repect patient distribution. independent nursing behavior(80.3% ) was the highest and depend ent nursing (31.7% ) the lowest. The variation co-efficient of treatment cost appeared highest in dependent nursing be havior as a whole, and among that, doctor's diagnosis showed the highest coefficient value (100.7). In conclusion, the variaty of treatment cost(treatment itself ) by various characteristics and treatment types pro- that treatment various sort of patients and treatment cost of various types of nursing behavior cannot be uniform. Therefore, to attain the equalization of health care service and its cost both for insurant and non-insurant patients, a more specific provision for assessment of cost should be added to the present medical care insurance system and, in addition, the cost of nursing treatment is desired to be inserted into the treatment invoice.

  • PDF

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF