• Title/Summary/Keyword: hospital patients

Search Result 28,813, Processing Time 0.067 seconds

Study of the Impact of Light Through the Vitamin $B_{12}$/Folate Inspection (Vitamin $B_{12}$/Folate 검사 시 빛의 영향에 대한 고찰)

  • Cho, Eun Bit;Pack, Song Ran;Kim, Whe Jung;Kim, Seong Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.162-166
    • /
    • 2012
  • Purpose : Vitamin $B_{12}$ and Folate are for anemia work-up which is well known for its sensitivity of light; the screening manual also specifies to be careful with light conditions. According to this, our laboratory minimized the exposure of light when inspecting the Vitamin $B_{12}$ and Folate, but the exposure cannot be wholly blocked due to other various factors such as when conducting specimen segregation. Thus, this inspection is to identify to what extent light can influence and whether the exclusion of light is mandatory during the Vitamin $B_{12}$/Folate test. Materials and Methods : We have conducted two experiments of identifying the extent of light's influence when conducting the Vitamin $B_{12}$/Folate test and also when specimens are under preservation. These experiments were progressed with various concentrations of patients' specimens which were requested to our hospital in March 2012. The first experiment is to verify the results on Vitamin $B_{12}$/Folate dependent on light exposure during the experiment. In the process, we have compared the results of light exposure/exclusion during the incubation process after the reagent division. The second experiment is about the impact of light exposure on the results on Vitamin $B_{12}$/Folate during the preservation. For 1, 2, 7 days the light on the specimen were wholly blocked and were preserved under $-15^{\circ}C$ temperature refrigeration. Then, we compared the results of light-excluded specimen and the exposed one. Results : When conducting first experiment, there were no noticeable changes in the Standard and specimen's cpm, but for Vitamin $B_{12}$, the average result of specimen exposed to light increased 7.8% compare to that of excluded one's. Furthermore, in the significant level 0.05, the significance probability or the p-value was 0.251 which means it has no impact. For Folate, the result being exposed to light decreased 5.4%, the significance probability was 0.033 which means it has little impact. For the second preservation, the result was dependent on the light exposure. The first day of preservation of Vitamin $B_{12}$, the clinical material exposed to light was 11.6%, second day clinical material exposed to light was 10.8%, seventh day clinical material exposed to light increased 3.8%, the significance probability of the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.372, 0.033, 0.144 respectively, and which indicates that the $1^{st}$ and $7^{th}$ day seems to have no impact. For Folate's case, the clinical material exposed to light has increased 1.4% but hardly had impact, $2^{nd}$ day clinical material being exposed to light was 6.1%, $7^{Th}$ day clinical material being exposed to light decreased 5.2%. The significance probability of Folate on the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.378, 0.037, 0.217 respectively, and the $1^{st}$ day and the $7^{th}$ day seems to have no impact. Conclusion : After scrutinizing the impact of light exposure/exclusion, Vitamin $B_{12}$ has no impact, while Folate seems to have no noticeable influence but light exclusion is recommended due to its significance probability of 0.033 when conducting experiment. During the preservation, the $2^{nd}$ day result depend on the light exclusion seems to have impact or influence. However, to consider the complication of the experimental process, the experiment including technical errors is predictable. Hence, it is likely to have no impact of light. Nevertheless, it is recommendable to exclude the light during the long preservation as per the significance probability (p-value) of $1^{st}$ and $7^{th}$ day has been diminished.

  • PDF

An Analysis of the Psychiatric Characteristics of the Alopecia Areata in Female (여성 탈모증의 정신의학적 특성 분석)

  • Lee, Kil-Hong;Na, Chul;Lee, Young-Sik;Lee, Chang-Hoon;No, Byung-In;Hong, Chang-Kwon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.1
    • /
    • pp.31-45
    • /
    • 2000
  • Objectives : The present study was performed to reveal differences between female and male cases of alopecia in their alopecia related variables such as patterns of hair loss, psychiatric characteristics, associate illnesses, and methods of treatment, and to use them as basic materials for proper management and early prevention of the alopecia prone cases. Methods : In order to analysis the gender difference in hair losses, the subjects were divided into two subgroups as the 51 cases of female alopecia and the 42 cases of male alopecia, who had visited to the department of psychiatry consulted from the department of dermatology, Yongsan hopital, ChungAng University, Seoul, Korea, from January 1998 to December 1998. In data analysis, the subjects were statistically assesed by chi-squre test and analysis of varaiance, through SPSS-$PC^+$ 9.0V. Results : 1) Female subjects were more likely showed lower socio-economical level including lower eonomical level, lower educational level, or lower occupational level in their parent's job, were more likely to have larger number of siblings and to have many sisters comparison to the male cases. 2) Female subjects were more likely visited to the department of dermatology, more history of alopecia in their female family members, lesser history of alopecia in their male family members, more loss of hairs in vertex or frontal region of scalp, lesser loss of hairs in occipital region, and lesser nail changes in comparison to the male cases. 3) Female subjects were more suffered from intra-familial conflicts and economical changes, or their introverted personality makeup, lesser likely suffered from changes of business and health changes, and showed lesser conflicts related with poorer adaptaion in their job life. 4) Female subjects were more likely diagnosed as depression or conversion disorders, more frequently complaint anxiety symptoms or depressive symptoms, higher level of anxiety index, lesser complaint somatization or obsessive compulsive symptoms, and lesser diagnosed as anxiety disorder in comparison to the male cases. 5) Female subjects were more likely tended to show personality makeup such as the introverted, the lie, the repressed, or the feminine trends than the male cases. 6) Female subjects were more significantly treated by antianxiety drug such as etizolam and dermatological therapies include tretinoin, and lesser treated by clotiazepam and prednicarbonate in comparison to the male cases. Conclusion : From the facts that The most important factors in developing hair loss in the female subjects in comparison to the male cases seems to be closely correlated with the serious psychopathology such as the presence of mental disorders including depression, the presence of complaining anxiety or depressive symptomatology, the presence of stressful life events such as intrafamilial life changes, and the presence of personality makeup such as the introverted, the lie, the repressed, or the feminine trends, the authors confirmed that dermatologists act as the primary care physician are in a unique position to recognize psychiatric comorbidity and execute meaningful intervention for female patients with the alopecia with psychiatrists.

  • PDF

Differential Diagnosis By Analysis of Pleural Effusion (흉수분석에 의한 질병의 감별진단)

  • Ko, Won-Ki;Lee, Jun-Gu;Jung, Jae-Ho;Park, Mu-Suk;Jeong, Nak-Yeong;Kim, Young-Sam;Yang, Dong-Gyoo;Yoo, Nae-Choon;Ahn, Chul-Min;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.559-569
    • /
    • 2001
  • Background : Pleural effusion is one of the most common clinical manifestations associated with a variety of pulmonary diseases such as malignancy, tuberculosis, and pneumonia. However, there are no useful laboratory tests to determine the specific cause of pleural effusion. Therefore, an attempt was made to analyze the various types of pleural effusion and search for useful laboratory tests for pleural effusion in order to differentiate between the diseases, especially between a malignant pleural effusion and a non-malignant pleural effusion. Methods : 93 patients with a pleural effusion, who visited the Severance hospital from January 1998 to August 1999, were enrolled in this study. Ultrasound-guided thoracentesis was done and a confirmational diagnosis was made by a gram stain, bacterial culture, Ziehl-Neelsen stain, a mycobacterial culture, a pleural biopsy and cytology. Results : The male to female ratio was 56 : 37 and the average age was $47.1{\pm}21.8$ years. There were 16 cases with a malignant effusion, 12 cases with a para-malignant effusion, 36 cases with tuberculosis, 22 cases with a para-pneumonic effusion, and 7 cases with transudate. The LDH2 fraction was significantly higher in the para-malignant effusion group compared to the para-pneumonic effusion group [$30.6{\pm}6.4%$ and $20.2{\pm}7.5%$, respectively (p<0.05)] and both the LDH1 and LDH2 fraction was significantly in the para-malignant effusion group compared to those with tuberculosis [$16.4{\pm}7.2%$ vs. $7.6{\pm}4.7%$, and $30.6{\pm}6.4%$ vs.$17.6{\pm}6.3%$, respectively (p<0.05)]. The pleural effusion/serum LDH4 fraction ratio was significantly lower in the malignant effusion group compared to those with tuberculosis [$1.5{\pm}0.8$ vs. $2.1{\pm}0.6$, respectively (p<0.05)]. The LDH4 fraction and the pleural effusion/serum LDH4 fraction ratio was significantly lower in the para-malignant effusion group compared to those with tuberculosis [$17.0{\pm}5.8%$ vs. $23.5{\pm}4.6%$ and $1.3{\pm}0.4$ vs. $2.1{\pm}0.6$, respectively (p<0.05)]. Conclusion : These results suggest that the LDH isoenzyme was the only useful biochemical test for a differential diagnosis of the various diseases. In particular, the most useful test was the pleural effusion/serum LDH4 fraction ratio to distinguish between a para-malignant effusion and a tuberculous effusion.

  • PDF

Measurement of Bone mineral density According to Middle aged Women with Low Back Pain (중년여성의 요통에 따른 골밀도 측정)

  • Kang, Jeom-Deok;Kim, Jong-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.5-28
    • /
    • 2001
  • Objectives: The objective of this study was to investigate analysis of bone mineral density according to Women with low back pain women. Methods: The data were collected from women who visited Physical Examination Center of a Catholic university hospital located in Daegu. Questionnaires were completed by 50 women during the period from July 20, 2000 to January 12, 2001. The sample was divided into three groups(the normal group of 16 cases and the osteopenia group of 12cases and the osteoporosis group of 22 cases). Bone mineral density(BMD) of lumbar spine was measured using energy absorptiometry. Results: The bone mineral density of the lumbar spine decreased with aging. The bone mineral density of the lumbar spine decreased with the serum Calcium and Phosphorus and Alkaline phosphatase increased. The mean bone mineral density of the lumbar spine of healthy women in age(50~59) was 0.87g/$cm^2$, the lumbar spine of women with low back pain in age(50~59) was 0.77g/$cm^2$. In the multiple regression of risk factors to bone mineral density(BMD) of lumbar spine were correlated with age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores(p<0.05). The experience for LBP increased as weight increased(Odds ratio=999.000). The experience for LBP increased as number of Exercise decreased(Odds ratio=999.000). The experience for LBP increased as menopause existence increased(Odds ratio=999.000). The experience for LBP increased as serum Calcium and Phosphorus increased (Odds ratio=999.000). however all four variables had significant no relationship. The correlation in variables in relation to low back pain and bone mineral density, age showed contra-correlation with low back pain existence, Alkaline phosphatase(p<0.01). Weight showed contra-correlation with body mass index(BMI)(p<0.01). Exercise time showed correlation with number of exercise(p<0.01). The loving food of taste showed contra-correlation with Alkaline phosphatase(p<0.05). Bone mineral density showed correlation with menopause existence(p<0.05). Conclusions: Results from this study indicated that a statistically significant association between bone mineral density of the lumbar spin and age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores. In logistic regression test, there were no related variables. The combination of bone mineral density measurement and assessment of the bone turnover rate by measuring biochemical would be helpful for the treatment of patients with risks of osteoporosis. The more precise study for risk factors to osteoporosis is essential.

  • PDF

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

Changes of Brain Natriuretic Peptide Levels according to Right Ventricular HemodynaMics after a Pulmonary Resection (폐절제술 후 우심실의 혈역학적 변화에 따른 BNP의 변화)

  • Na, Myung-Hoon;Han, Jong-Hee;Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Choi, Jae-Sung;Yoon, Seok-Hwa;Choi, Si-Wan
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.593-599
    • /
    • 2007
  • Background: The correlation between levels of brain natriuretic peptide (BNP) and the effect of pulmonary resection on the right ventricle of the heart is not yet widely known. This study aims to assess the relationship between the change in hemodynamic values of the right ventricle and increased BNP levels as a compensatory mechanism for right heart failure following pulmonary resection and to evaluate the role of the BNP level as an index of right heart failure after pulmonary resection. Material and Method: In 12 non small cell lung cancer patients that had received a lobectomy or pnemonectomy, the level of NT-proBNP was measured using the immunochemical method (Elecsys $1010^{(R)}$, Roche, Germany) which was compared with hemodynamic variables determined through the use of a Swan-Garz catheter prior to and following the surgery. Echocardiography was performed prior to and following the surgery, to measure changes in right ventricular and left ventricular pressures. For statistical analysis, the Wilcoxon rank sum test and linear regression analysis were conducted using SPSSWIN (version, 11.5). Result: The level of postoperative NT-proBNP (pg/mL) significantly increased for 6 hours, then for 1 day, 2 days, 3 days and 7 days after the surgery (p=0.003, 0.002, 0.002, 0.006, 0.004). Of the hemodynamic variables measured using the Swan-Ganz catheter, the mean pulmonary artery pressure after the surgery when compared with the pressure prior to surgery significantly increased at 0 hours, 6 hours, then 1 day, 2 days, and 3 days after the surgery (p=0.002, 0,002, 0.006, 0.007, 0.008). The right ventricular pressure significantly increased at 0 hours, 6 hours, then 1 day, and 3 days after the surgery (p=0.000, 0.009, 0.044, 0.032). The pulmonary vascular resistance index [pulmonary vascular resistance index=(mean pulmonary artery pressure-mean pulmonary capillary wedge pressure)/cardiac output index] significantly increased at 6 hours, then 2 days after the surgery (p=0.008, 0.028). When a regression analysis was conducted for changes in the mean pulmonary artery pressure and NT-proBNP levels after the surgery, significance was evident after 6 hours (r=0.602, p=0.038) and there was no significance thereafter. Echocardiography displayed no significant changes after the surgery. Conclusion: There was a significant correlation between changes in the mean pulmonary artery pressure and the NT-proBNP level 6 hours after a pulmonary resection. Therefore, it can be concluded that changes in NT-proBNP level after a pulmonary resection can serve as an index that reflects early hemodynamic changes in the right ventricle after a pulmonary resection.

A study on dermatologic diseases of workers exposed to cutting oil (절삭유 취급 근로자의 피부질환에 관한 연구)

  • Chun, Byung-Chul;Kim, Hee-Ok;Kim, Soon-Duck;Oh, Chil-Hwan;Yum, Yong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.785-799
    • /
    • 1996
  • We investigated the 1,004 workers who worked in a automobile factory to study the epidemiologic characterists of dermatoses due to cutting oils. Among the workers, 667(66.4%) answered the questionaire. They are belong to 5 departments of the factory-the Engine-Work(258 workers), Gasoline engine Assembly(210), Diesel engine Assembly(96), Power train Work(86), Power train Assembly(17). We measured the oil mist concentration in air of the departments and examined the workers who had dermatologic symptoms. The results were follows; 1) Oil mist concentration ; Of all measured points(52),9 points(17.2%) exeeded $5mg/m^3$- the time-weighed PEL-and one department had a upper confidence limit(95%) higher than $5mg/m^3$. 2) Dermatologists examined 213 workers. 172 of them complained any skin symptoms at that time - itching(32.5%), papule(21.6%), scale(15.7%), vesicle(12.5%) in order. The abnormal skin site found by dermatologist were palm(29.3%), finger & nail(24.6%), forearm(16.2%), back of hand(8.4%) in order. 3) As the result of physical examination, we found that 160 workers had skin diseases. Contact dermatitis was the most common; 69 workers had contact dermatitis alone(43.1%), 11 had contact dermatitis with acne(6.9%), 10 had contact dermatitis with folliculitis(6.3%), 1 had contact dermatitis with acne & folliculitis, and 1 had contact dermatitis with abnormal pigmentation. Others were folliculitis(9 workers, 5.6%), acne(8, 5.0%), folliculitis & acne (2, 1.2%), keratosis(1, 0.6%), abnormal pigmentation (1, 0.6%), and non-specific hand eczema (47, 29.3%). 4) The prevalence of any skin diseases was 34.0 pet 100 in cutting oil users, and 13.3 per 100 in non- users. Especially, the prevalence of contact dermatitis was 23.0 per 100 in cutting oil users and 23.0 per 100 in non-users. 5) We tried patch test(standard serise, oil serise, organic solvents) on 49 patients to differentiate allergic contact dermatitis from irritant contact dermatitis and found 20 were positive. 6) In a multivariate analysis(independant=age, tenure, kinds of cutting oil), the risk of skin diseases was higher in the water-based cutting oil user and both oil user than non-user or neat oil user(odds ratio were 2.16 and 2.78, respectively). And the risk of contact dermatitis was much higher at the same groups(odds ratio were 5.16 and 6.82, respectively).

  • PDF

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

A Study on the long-term Hemodialysis patient중s hypotension and preventation from Blood loss in coil during the Hemodialysis (장기혈액투석환자의 투석중 혈압하강과 Coil내 혈액손실 방지를 위한 기초조사)

  • 박순옥
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.83-104
    • /
    • 1981
  • Hemodialysis is essential treatment for the chronic renal failure patient's long-term cure and for the patient management before and after kidney transplantation. It sustains the endstage renal failure patient's life which didn't get well despite strict regimen and furthermore it becomes an essential treatment to maintain civil life. Bursing implementation in hemodialysis may affect the significant effect on patient's life. The purpose of this study was to obtain the basic data to solve the hypotension problem encountable to patient and the blood loss problem affecting hemodialysis patient'a anemic states by incomplete rinsing of blood in coil through all process of hemodialysis. The subjects for this study were 44 patients treated hemodialysis 691 times in the hemodialysis unit, The .data was collected at Gang Nam 51. Mary's Hospital from January 1, 1981 to April 30, 1981 by using the direct observation method and the clinical laboratory test for laboratory data and body weight and was analysed by the use of analysis of Chi-square, t-test and anlysis of varience. The results obtained an follows; A. On clinical laboratory data and other data by dialysis Procedure. The average initial body weight was 2.37 ± 0.97kg, and average body weight after every dialysis was 2.33 ± 0.9kg. The subject's average hemoglobin was 7.05±1.93gm/dl and average hematocrit was 20.84± 3.82%. Average initial blood pressure was 174.03±23,75mmHg and after dialysis was 158.45±25.08mmHg. The subject's average blood ion due to blood sample for laboratory data was 32.78±13.49cc/ month. The subject's average blood replacement for blood complementation was 1.31 ±0.88 pint/ month for every patient. B. On the hypotensive state and the coping approaches occurrence rate of hypotension was 28.08%. It was 194 cases among 691 times. 1. In degrees of initial blood pressure, the most 36.6% was in the group of 150-179mmHg, and in degrees of hypotension during dialysis, the most 28.9% in the group of 40-50mmHg, especially if the initial blood pressure was under 180mmHg, 59.8% clinical symptoms appeared in the group of“above 20mmHg of hypotension”. If initial blood pressure was above 180mmHg, 34.2% of clinical symptoms were appeared in the group of“above 40mmHg of hypotension”. These tendencies showed the higher initial blood pressure and the stronger degree of hypotension, these results showed statistically singificant differences. (P=0.0000) 2. Of the occuring times of hypotension,“after 3 hrs”were 29.4%, the longer the dialyzing procedure, the stronger degree of hypotension ann these showed statistically significant differences. (P=0.0142). 3. Of the dispersion of symptoms observed, sweat and flush were 43.3%, and Yawning, and dizziness 37.6%. These were the important symptoms implying hypotension during hemodialysis accordingly. Strages of procedures in coping with hypotension were as follows ; 45.9% were recovered by reducing the blood flow rate from 200cc/min to 1 00cc/min, and by reducing venous pressure to 0-30mmHg. 33.51% were recovered by controling (adjusting) blood flow rate and by infusion of 300cc of 0,9% Normal saline. 4.1% were recovered by infusion of over 300cc of 0.9% normal saline. 3.6% by substituting Nor-epinephiine, 5.7% by substituting blood transfusion, and 7,2% by substituting Albumin were recovered. And the stronger the degree of symptoms observed in hypotention, the more the treatments required for recovery and these showed statistically significant differences (P=0.0000). C. On the effects of the changes of blood pressure and osmolality by albumin and hemofiltration. 1. Changes of blood pressure in the group which didn't required treatment in hypotension and the group required treatment, were averaged 21.5mmHg and 44.82mmHg. So the difference in the latter was bigger than the former and these showed statistically significant difference (P=0.002). On the changes of osmolality, average mean were 12.65mOsm, and 17.57mOsm. So the difference was bigger in the latter than in the former but these not showed statistically significance (P=0.323). 2. Changes of blood pressure in the group infused albumin and in the group didn't required treatment in hypotension, were averaged 30mmHg and 21.5mmHg. So there was no significant differences and it showed no statistical significance (P=0.503). Changes of osmolality were averaged 5.63mOsm and 12.65mOsm. So the difference was smaller in the former but these was no stitistical significance (P=0.287). Changes of blood pressure in the group infused Albumin and in the group required treatment in hypotension were averaged 30mmHg and 44.82mmHg. So the difference was smaller in the former but there is no significant difference (P=0.061). Changes of osmolality were averaged 8.63mOsm, and 17.59mOsm. So the difference were smaller in the former but these not showed statistically significance (P=0.093). 3. Changes of blood pressure in the group iutplemented hemofiltration and in the Uoup didn't required treatment in hypotension were averaged 22mmHg and 21.5mmHg. So there was no significant differences and also these showed no statistical significance (P=0.320). Changes of osmolality were averaged 0.4mOsm and 12.65mOsm. So the difference was smaller in the former but these not showed statistical significance(P=0.199). Changes of blood pressure in the group implemented hemofiltration and in the group required treatment in hypotension were averaged 22mmHg and 44.82mmHg. So the difference was smatter in the former and these showed statistically significant differences (P=0.035). Changes of osmolality were averaged 0.4mOsm and 17.59mOsm. So the difference was smaller in the former but these not showed statistical significance (P=0.086). D. On the changes of body weight, and blood pressure, between the group of hemofiltration and hemodialysis. 1, Changes of body weight in the group implemented hemofiltration and hemodialysis were averaged 3.340 and 3.320. So there was no significant differences and these showed no statistically significant difference, (P=0.185) but standard deviation of body weight averaged in comparison with standard difference of body weight was statistically significant difference (P=0.0000). Change of blood Pressure in the group implemented hemofiltration and hemodialysis were averaged 17.81mmHg and 19.47mmHg. So there was no significant differences and these showed no statistically significant difference (P=0.119), But in comparison with standard deviation about difference of blood pressure was statistically significant difference. (P=0.0000). E. On the blood infusion method in coil after hemodialysis and residual blood losing method in coil. 1, On comparing and analysing Hct of residual blood in coil by factors influencing blood infusion method. Infusion method of saline 200cc reduced residual blood in coil after the quantitative comparison of Saline Occ, 50cc, 100cc, 200cc and the differences showed statistical significance (p < 0.001). Shaking Coil method reduced residual blood in Coil in comparison of Shaking Coil method and Non-Shaking Coil method this showed statistically significant difference (P < 0.05). Adjusting pressure in Coil at OmmHg method reduced residual blood in Coil in comparison of adjusting pressure in Coil at OmmHg and 200mmHg, and this showed statistically significant difference (P < 0.001). 2. Comparing blood infusion method divided into 10 methods in Coil with every factor respectively, there was seldom difference in group of choosing Saline 100cc infusion between Coil at OmmHg. The measured quantity of blood loss was averaged 13.49cc. Shaking Coil method in case of choosing saline 50cc infusion while adjusting pressure in coil at OmmHg was the most effective to reduce residual blood. The measured quantity of blood loss was averaged 15.18cc.

  • PDF