• Title/Summary/Keyword: hospital exposure

Search Result 1,516, Processing Time 0.035 seconds

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

The Relationship between Behavior of Radiographic Safety Control and Job Stress in Dental Hygienist (치과위생사의 방사선안전관리 행위와 직무스트레스와의 관계)

  • Jang, Jong-Hwa;Hwang, Su-Lyun;Jung, Hong-ryang
    • Journal of dental hygiene science
    • /
    • v.10 no.4
    • /
    • pp.265-271
    • /
    • 2010
  • This study was to investigate the level of knowledge, recognition, behavior of radiographic safety control and job stress in dental hygienists and to determine the relationship among variables. The subjects were 256(56.9%), who were worked in dental hospital and clinic with mean age of $29.59{\pm}7.30$. Data was collected using a self administrated questionnaire from April 4 to May 15, 2010. Behavior of radiographic safety control was measured using the 15-items and job stress was measured using the 5-items with 5-point likert scale. The data were analyzed with t-test, one-way ANOVA and pearson correlation coefficient using the SPSS WIN 17.0 program. Regarding job stress, the subjects was a mean of 2.63 out of a maximum 5 points. The level of knowledge, recognition, behavior of radiographic safety control a mean of 3.11, 4.08 and 3.43 out of a maximum 5 points. Recognition and behavior of radiographic safety control was negative related job stress in this study. Based on the findings, behavior of radiographic safety control is associated with job stress. These results suggest that various program should be considered for radiation safety control of dental hygienists.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

A Study of Knowledge, Attitude, and Practice Relative to Maternal and Child Health Among Women Residing in Apartments at Yonsei Community Health Area (연세지역 아파트 주민의 모자보건에 관한 실태조사)

  • Yu, Seung-Hum;Chung, Young-Sook;Lee, Kyung-Ja;Kim, Kwang-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.77-87
    • /
    • 1971
  • A study of the knowledge, attitude and practices about the maternal and child health of 305 married women residing in apartments at the Yonsei Community Health area was conducted during the period from November to December 1970 using designed questionnaire with well trained interviewers. The results and findings obtained from the study are summarized as follows: A. Pregnancy and Birth Questions were asked about their last child. 1. 16.4% of the women were pregnant. 2. Among 281 women who had experienced delivery, 48.0% were assisted by doctor or midwisves for their last delivery, while the rest of women delivered their last baby at home without any professional's assistance. The higher the level of education or the greater exposure to mass communication, the more the deliveries were assisted by doctors or midwives. Those women who were born and raised in cities had more deliveries assisted by doctors and midwives than those who were not. 3. Kinds of delivery sheets used. Among 141 cases of home delivery 68% used cement bag paper or vinyl sheets. Three% used nothing and remained used unsterile materials. 4. Among 141 cases of home delivery, 70.2% used scissors. The rest of them used other methods. 5. 47.3% of the women had a rest for one month or more after birth. The higher the level of education, the longer the period of rest was observed. 6. 52.4% of the women fed the colostrum to their babies. This was not related to the mother's education. 7 About half(42.9%) of the women had poor knowledge about a proper diet for the pre and post natal period. B. Child Health 1. Knowledge and practice regarding to the immunization for their children: Most of the women (93.2%) could name at least one kind of immunization. 20.3% could name 6 kinds of immunization. Mothers education level did not influence their ability to name immunizations. 85.2% of children had been immunized at least once. 2. Morbidity of last born children: 48.1% of their last born children were found to have been sick during the last year. Less than half(41.5%) of the sick children were seen by doctor. 3. Counselling at well baby clinic: Most of the women(76.5%) had no counselling for their children. Registration rate at the well baby clinic at the Severance Hospital was 13.2%. 45.9% wanted to visit to the well baby clinic at the Severance Hospital. 4. Weaning Period: 44.6% said that the beginning of the weaning for their last born children was from 6 months to twelve months of age. The most important reason of weaning was the health of both mothers and children. 5. Knowledge and Practice regarding birth and death Registration: 64.6% of the women could name correctly the Ku-office as the place for the registration. Only 29.2% registered the birth of their last born children within 14 days. C. Knowledge, Attitude and Practice regarding to family planning Most: of the women accepted the idea of family planning. 97.7% could name at least one contraceptive method. 35.4% were found to be current users of contraceptive methods. The ideal number of children was 3.1 in average.

  • PDF

A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry (치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구)

  • Park, Ilwoo;Jeung, Wonkyo;Hwang, Hyungsuk;Lim, Sunghwan;Lee, Daenam;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • This study estimate radiation biological danger factor by measuring patient's exposed dose and propose the low way of patient's exposed dose in panoramic radiography. We seek correcting constant of OSL dosimeter for minimize the error of exposed dose's measurement and measure the Left, Right crystalline lens, thyroid, directly included upper, lower lips, the maxillary bone and the center of photographing that indirect included in panoramic radiography by using the human body model standard phantom advised in ICRP. In result, the center of photographing's level of radiation maximum value is $413.67{\pm}6.53{\mu}Gy$ and each upper, lower lips is $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$. Also in panoramic radiography, indirect included Left, Right crystalline lens's level of radiation are $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$, and thyroid's level of measured exposed dose can cause effect of radiation biological and we need justifiable analysis about radiation defense rule and substantiation advised international organization for the low way of patient's exposed dose in panoramic radiography of dental clinic and we judge need the additional study about radiation defense organization for protect the systematize protocol's finance and around internal organs for minimize until accepted by many people that is technological, economical and social fact by using panoramic measurement.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

Questions and Answers about the Humidifier Disinfectant Disaster as of February 2017 (가습기살균제 참사의 진행과 교훈(Q&A))

  • Choi, Yeyong
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.1-22
    • /
    • 2017
  • 'The worstest environment disaster', 'World's first biocide massacre', 'Home-based Sewol ferry disaster' are all phrases attached to the recent humidifier disinfectant disaster. In the spring of 2011, four of 8 pregnant women including 1 adult man passed away at a university hospital in Seoul due to breathing failure. Epidemiologic investigation conducted by the Korean CDC soon revealed the inhalation of humidifier disinfectant, which had been widely used in Korea during the winter, to be responsible for the disease. As well as lung fibrosis hardening of the lungs, other diseases including asthma, rhinitis, skin disease, liver disease, fetal disease or cancers have been researched for their relation with exposure to the products. By February 9, 2017, 5,342 cases had registered for health problems and 1,131 of them were already dead (20.8% mortality rate). Based on studies by government agencies and a telephone survey of the general population by Seoul National University and civic groups, around 20% of the general public of Korea has used these products. Since the market release of the first product by SK Chemical in 1994, over 7.1 million items from around 20 brands were sold up to 2011. Most of the products were manufactured by well-known large conglomerates such as SK, Lotte, Samsung, Shinsegye, LG, and GS, as well as some European companies including UK-based Reckitt Benckiser and TESCO, the German firm Henkel, the Danish firm KeTox, and an Irish company. Even though this disaster was unveiled in 2011 by the Korean government, the issue of the victims was neglected for over five years. In 2016, an unexpected but intensive investigation by prosecutors found that Reckitt Benckiser manipulated and concealed animal tests for its own brand and brought several university experts and company employees to court. The matter was an intense social issue in Korea from May to June with a surge in media coverage. The prosecutor's investigation and a nationwide boycott campaign organized by victims and environmental groups against Reckitt Benckiser, whose product had been used by more than 70% of victims, led to the producer's official apology and a compensation scheme. A legislative investigation organized after the April 2016 national election revealed the producers' faults and the government's responsibility, but failed to meet expectations. A special law for the victims passed the National Assembly in January 2017 and a punitive system together with a massive environmental epidemiology investigation are expected to be the only solutions for this tragedy. Sciences of medicine, toxicology and environmental health have provided decisive evidence so far, but for the remaining problems the perspectives of social sciences such as sociology and jurisprudence are highly necessary, similar to with the Minamata disease and Wonjin Rayon events. It may not be easy to follow this issue using unfamiliar terminology from medical and chemical science and the long, complicated history of the event. For these reasons the author has attempted to write this article in a question and answer format to render it easier to follow. The 17 questions are: Q1 What is humidifier disinfectant? Q2 What kind of health problems are caused by humidifier disinfectant? Q3 How many victims are there? Q4 What is the analysis of the 1,112 cases of death? Q5 What is the problem with the government's diagnostic criteria and the solution? Q6 Who made what brands? Q7 Has there been a recall? What is still on sale? Q8 Was safety not checked by any producers? Q9 What are the government's responsibilities? Q10 Is it true that these products were sold only in Korea? Q11 Why and how was it unveiled only in 2011 after 17 years of sales? Q12 What delayed the resolution of the victim issue? Q13 What is the background of the prosecutor's investigation in early 2016? Q14 Is it possible to report new victim cases without evidence of product purchase? Q15 What is happening with the victim issue? Q16 How does it compare with the cases of Minamata disease and Wonjin Rayon? Q17 Are there prevention measures and lessons?

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

The Prognostic Factors in Progression of Pneumoconiosis (진폐증의 예후에 영향을 미치는 인자)

  • Kim, Hyung-Ju;Jang, An-Soo;Kim, Sang-Guk;Choi, Soo-In;Park, Sang-Hoo;Yang, Seung-Won;Seo, Jeong-Pyeong;Lee, Soong;Park, Hong-Bae;Son, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.57-65
    • /
    • 1999
  • Backround : Pneumoconiosis is the parenchymal lung disease that results from the inhalation and deposition of dust, usually mineral dust of occupational or environmental origin. Most of the pneumoconiosis can be categorized to coal workers' pneumoconiosis (CWP) in Korea. No effective treatement is currently available, and the therapy for symptomatic CWP is limited to treatment of complication. Therefore authors analyzed and reviewed clinical features and radiological findings of 95 patients with pneumoconiosis for assessing the prognostic factors in disease progression. Method: We reviewed medical records of 95 cases with pneumoconiosis including history, chest X-ray, pulmonary function test, electrocardiography, AFB stain and culture of sputum, and routine blood examination between June 1995 and June 1997 in Seonam University Namkwang Hospital. Results: All of cases are male(mean age, 57.4 years), 91 cases out of them are miners. The mean duration of exposure to dust is 18.8 years. Major clinical symptoms are dyspnea (100%), sputum (71.6%), chest pain (55.8%), cough (23.2%), and hemoptysis (6.3%). 82 % of cases are over Morgan-Seaton Grade 2 in the degree of dyspnea. Small opacity on chest x-ray is 82.1 % and large opacity is 17.9%. Small opacity has tit type (37.2%), q/q type (25.6%) and r/r type (11.5%). B type is 42.2% in large opacity. For the pulmonary function test, restrictive type is 40.3%, mixed type 19.5% and obstructive type 8.3%. The more increasing chest Xray density, the more decreasing $FEV_1$ (p<0.01). 38% of patients show tuberculosis in chest X-ray, 15.8% positive smear of acid fast bacilli in sputum. The prevalence of pulmonary tuberculosis is high in patients with poor clinical condition. The cases with the active pulmonary tuberculosis have severe dyspnea. Expired cases show 100% and 75% of positive pulmonary tuberculosis in chest X-ray and sputum examination, respectively. 75% of expired cases show the chronic cor pulmonale, who died of acute respiratory failure. Conclusion: These findings indicate that tuberculoois infection has a decisive influence on the progress and prognoois of pneumoconioois.

  • PDF