• Title/Summary/Keyword: horizontal well

Search Result 1,395, Processing Time 0.025 seconds

Proposal of Modified Correlation to Calculate the Horizontal Global Solar Irradiance for non-Measuring Cloud-cover Regions (운량 비측정 지역을 위한 수평면전일사량 예측 상관식의 수정모델 제안)

  • Cho, Min-Cheol;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.6 no.2
    • /
    • pp.29-33
    • /
    • 2016
  • Recently, the authors of this paper proposed newly the correlation model to calculate the horizontal global solar radiation in Korea based the Zhang-Huang (ZH) model proposed in 2002 for China. Previous study was pronounced the correlation with a new term of the duration of sunshine proved as being closely related with the hourly solar radiation in Korea into ZH model. And then another modified correlation for the regions without measuring cloud cover was proposed and evaluated the accuracy and validity for those regions. So, this study was performed to propose modified correlation to calculate the horizontal global solar irradiance of non-measuring cloud-cover regions. Finally, this study proposed the new correlation that could well predict hourly and daily total solar radiation for all regions, various seasons, and various weather conditions including overcast and clear, with higher accuracy and lower error than other models proposed ever before in Korea for non-measuring cloud-cover regions.

A Detailed Survey on the Solar Availability for the Construction of Photovoltaic Power Generation Sites (태양광발전단지 건설을 위한 태양광자원 정밀조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Lee, Euy-Joon;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2004
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar photovoltaic system users as well as by research institutes From the results, we can conclude that 1) The yearly averaged horizontal global insolation of Korea was turned out $3.57kWh/m^2.day$ in the periods of $1982\sim2001$. 2) Horizontal global insolation of spring and summer was respectively 24 % and 21 % higher than the yearly average value, and that of fall and winter was respectively 12 % and 34 % lower than the yearly average value.

Heat Transfer Correlations for Air-Water Two-Phase Flow of Different Flow Patterns In a Horizontal Pipe

  • Kim, Dongwoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1711-1727
    • /
    • 2001
  • Heat transfer coefficient were measured and new correlations were developed for two-phase heat transfer in a horizontal pipe for different patterns. Flow patterns were observed in a transparent circular pipe (2.54 cm I. D. and L/D=96) using an air/water mixture. Visual identification of the flow patterns was supplemented with photographic data and the results were plotted on the flow regime map proposed by Taitel and Dukler and agreed quite well with each other. A two-phase heat transfer experimental setup was built for this study and a total of 150 two-phase heat transfer data with different flow patterns were obtained under a uniform wall heat flux boundary condition. For these data, the superficial Reynolds number ranged from 640 to 35,500 for the liquid and from 540 to 21,200 for the gas. Our previously developed robust two-phase heat transfer correlation for a vertical pipe with modified constants predicted the horizontal pipe air-water heat transfer experimental data with good accuracy. Overall the proposed correlations predicted the data with a mean deviation of 1.0% and an rms deviation of 12%.

  • PDF

Fatigue Characteristics of Bicycle Frames Depending on Types and Materials (자전거 프레임의 소재 및 종류에 따른 피로특성)

  • Kwon, Kyoung-Bae;Cheong, Seong Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.8-12
    • /
    • 2017
  • Bicycles are very popular sporting goods in these days. Thus, the durability of bicycles is very important for the safety of bicyclists. It is well known that a bicycle frame is a major component which is essential to the safety and performance of a complete bicycle. In this study, the durability of bicycle frames were experimentally investigated under the fatigue load. Eighty bicycle frames with different types and materials were prepared and tested according to EN standards. Three kinds of fatigue loads, that is, pedalling, vertical and horizontal fatigue load, which occur constantly during riding a bicycle, were applied to the bicycle frames. The experimental results show that the horizontal fatigue load was the severest mode to pass EN standard. The pass ratio of horizontal fatigue load test was 45.2%, while the pass ratio of vertical fatigue load test was 100%. Most of cracks were found at the right side of bottom bracket shell and at the intersection area between head tube and down tube. It seems that the experimental results can be applied to improve the safety and performance of a bicycle frame.

Thermal Diffusivity Measurement of Backfilling Materials for Horizontal Ground Heat Exchanger Using Dual-Probe Method (이중탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 측정)

  • Sohn, Byong-Hu;Choi, Hang-Seok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.51-59
    • /
    • 2011
  • Storage and transfer heat in soils are governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the measured results of the thermal diffusivity of soils(silica, quartzite, limestone, sandstone, and masonry soils) used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities and volumetric heat capacities using dual-probe method and (ii) compare the estimates from the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Measurements made by using the dual-probe method agreed well with independent estimates obtained using the single-probe method.

Quantitative observation of co-current stratified two-phase flow in a horizontal rectangular channel

  • Lee, Seungtae;Euh, Dong-Jin;Kim, Seok;Song, Chul-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.267-283
    • /
    • 2015
  • The main objective of this study is to investigate experimentally the two-phase flow characteristics in terms of the direct contact condensation of a steam-water stratified flow in a horizontal rectangular channel. Experiments were performed for both air-water and steam-water flows with a cocurrent flow configuration. This work presents the local temperature and velocity distributions in a water layer as well as the interfacial characteristics of both condensing and noncondensing fluid flows. The gas superficial velocity varied from 1.2 m/s to 2.0 m/s for air and from 1.2 m/s to 2.8 m/s for steam under a fixed inlet water superficial velocity of 0.025 m/s. Some advanced measurement methods have been applied to measure the local characteristics of the water layer thickness, temperature, and velocity fields in a horizontal stratified flow. The instantaneous velocity and temperature fields inside the water layer were measured using laser-induced fluorescence and particle image velocimetry, respectively. In addition, the water layer thickness was measured through an ultrasonic method.

A Study on the Characteristics of Horizontal Global Insolation Distribution in Korea (국내 수평면 전일사량 자원의 분포특성 분석)

  • Jo, D.K.;Chun, I.S.;Lee, S.M.;Lee, T.K.;Kang, Y.H.;Auh, C.M.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.19-30
    • /
    • 2000
  • Since the solar radiation is the main input for sizing any solar system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has began collecting horizontal global insolation data since May, 1982 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar system users as well as by research institutes. From the results, we can conclude that 1) The yearly averaged horizontal global insolation of Korea was turned out $3,042kcal/m^2.day$ in the periods of $1982\sim1999$. 2) Horizontal global insolation of spring and summer were 24 % and 21 %, higher than the yearly average value, respectively, and for fall and winter, their values were 12 % and 34 % lower than the yearly average value, respectively.

  • PDF

The horizontal stability of an FLNG with different turret locations

  • Xie, Zhi-Tian;Yang, Jian-Min;Hu, Zhi-Qiang;Zhao, Wen-Hua;Zhao, Jing-Rui
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.2
    • /
    • pp.244-258
    • /
    • 2015
  • The horizontal stability of a Single-Point Moored (SPM) Floating Liquefied Natural Gas (FLNG) facility is investigated. Both numerical and experimental studies have been conducted for this SPM FLNG. The numerical simulations feature well the experimental data. The effects of the turret locations are studied based on the validated numerical model. Statistic results of the vessel's motions with different turret locations are conducted and compared. The results show that the longitudinal location of the turret has a significant influence on the horizontal stability, which has a strong relationship with the yaw and roll motions. The calculated top tensions on the hawsers also develop a regular change as changing the turret's location. The investigation will provide a brief of principles with more details for the design of the ongoing project.

Evaluation of Conventional Prediction Model for Soil Thermal Conductivity to Design Horizontal Ground Heat Exchanger (수평형 지중열교환기 설계를 위한 토양 열전도도 예측 모델 평가)

  • Sohn, Byong-Hu;Wi, Ji-Hae;Han, Eun-Seon;Lim, Jee-Hee;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.813-824
    • /
    • 2010
  • Thermal conductivity of soils is one of the most important parameters to design horizontal ground heat exchangers. It is well known that the thermal conductivity of soil is strongly influenced by its density and water content because of soil's particulate structure. This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data available in the literature. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state sands. It came out that the model developed by Cote and Konrad gave the best overall prediction for unsaturated sands available in the literature. Also, a parametric analysis is conducted to investigate the effect of thermal conductivity and water content, soil type on the horizontal ground heat exchanger design. The analysis shows that a required pipe length for the horizontal ground heat exchanger is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that the dimension of the horizontal ground heat exchanger can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

  • PDF

An Observational Study on the Driver Behaviours at Long Tangent Sections Followed by Sharp Horizontal Curve (긴 직선-곡선 연결선형에서 운전자 주행행태에 관한 현장조사 연구)

  • Kim, Yong-Seok;Cho, Won-Bum
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.139-146
    • /
    • 2004
  • Road design should be conformed to the expectancy of drivers. The alignment such as long tangent followed by the sharp horizontal curve should be avoided for the road design consistency. Currently, operating speed profile model is generally used to check the consistency of the successive road alignments. In this model, the hypothesis about the drivers' behaviour on the long tangent followed by the sharp horizontal curve is also included. This study compares the hypothesized drivers' behaviour in the existing operating speed profile model with the actual drivers' behaviour observed at the two lane rural roads. In addition to this, comparison between the acceleration for the vehicles approaching and departing horizontal curves suggested by the foreign research and the value observed at this study was made, From this study, it was concluded that the hypothesis in the existing model was well representing the actual drivers' behaviour. The deceleration for vehicles approaching the horizontal curves was ranged $0.39{\sim}1.06m/s^2$ with the average of $0.66m/s^2$. The average acceleration for the vehicles departing horizontal curves was $0.22m/s^2$.