• Title/Summary/Keyword: horizontal slice method

Search Result 11, Processing Time 0.039 seconds

Numerical Experiments of Ocean Acoustic Tomography in the East Sea of Korea

  • Han, Sang-Kyu;Na, Jung-Yul;Lee, Jae-Hak
    • Journal of the korean society of oceanography
    • /
    • v.31 no.2
    • /
    • pp.64-74
    • /
    • 1996
  • Numerical experiments of OAT (Ocean Acoustic Tomography) are carried out in the East Sea of Korea where the canonical ocean has been perturbed by a mesoscale warm eddy and a thermal front. In order to estimate the horizontal and vertical structure of water temperature of the perturbed ocean, the experimental area is divided into 16 cells with 8 pairs of sources and receivers for a horizontal slice and the water column is divided into 8 layers for a vertical slice. The inversely estimated temperature field by using SVD (Singular Value Decomposition) method reveals the eddy and frontal structure clearly. The rms errors of the two horizontal slices are less than $0.4^{\circ}C$ and $1.7^{\circ}C$ at 400 m and 200 m depths, respectively, while the error in the vertical slice is less than $1.0^{\circ}C.$ For better estimation of temperature by OAT method, particularly for the East Sea, a range-dependent ray model should be used to solve the forward problem. At the same time, improvement in computing the refracted ray path between vertical layers is required to obtain more accurate travel time information. The results of the present experiment give rise to a possibility of application of OAT in remote sensing of the ocean thermal structure.

  • PDF

Implementation of DCT using Bit Slice Signal Processor (BIT SLICE SIGNAL PROCESSOR를 이용한 DCT의 구현)

  • Kim, Dong-L.;Go, Seok-B.;Paek, Seung-K.;Lee, Tae-S.;Min, Byong-G.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1449-1453
    • /
    • 1987
  • A microprogrammable Bit Slice Sinal Processor for image processing is implemented. Processing speed is increased by the parallelism in horizontal microprogram using 120bits microcode, pipelined architecture, 2 bank memory switching that interfaces with the Host through DMA, a variable clock control, overflow checking H/W,look-up table method and cache memory. With this processor, a DCT algorithm which uses 2-D FFT is performed. The execution time for $512{\times}512{\times}8$ image is 12 sec when 16 bit operation is runned, and the recovered image has acceptable quality with MSE 0.276%.

  • PDF

Stability Analysis of Soil Nailing System with Wall Displacements (벽체변위를 고려한 Soil Nailing공법의 안정해석)

  • Kim, Hong-Taek;Gang, In-Gyu;Seong, An-Je
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.119-122
    • /
    • 1994
  • An analytical procedure is described to estimate the mobilized tensile forces along the effective lengths of nails. Based on the horizontal focing displacements of a nailed-soil wall experiencing outward tilt about the toe with granular soil deposit, the variation of nail-soil friction coefficient is modeled. Also, the method of overall stability analysis of a nailed-soil wall is presented using the Morgenstem-Price limit-equilibrium slice method. The results predicted by the developed procedure are compared with test measurements. The comparisons show in general good agreement.

  • PDF

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

Analytical and ANN-based models for assessment of hunchback retaining walls: Investigating lateral earth pressure in unsaturated backfill

  • Sivani Remash Thottoth;Vishwas N Khatria
    • Geomechanics and Engineering
    • /
    • v.38 no.3
    • /
    • pp.285-305
    • /
    • 2024
  • This study investigates the behaviour of hunchback retaining walls supporting unsaturated sandy backfill under active earth pressure conditions. Utilizing a horizontal slice method and a unified effective stress methodology, the influence of various factors on lateral earth pressure, including the position of the hunch along the wall, friction angles, and wall heights, is explored. The results suggest that relocating the hunch position from close to the wall's top to near its base leads to a significant decrease (ranging from 54% to 81%) in lateral earth pressure. However, as the hunch position transitions from near the top to mid-height, the point of application of active thrust shifts upward initially, then slightly downward as the hunch position approaches the toe. Notably, the reduction in lateral earth pressure is more pronounced for shorter wall heights and higher friction angles. Building upon these findings, an Artificial Neural Network (ANN)-based model is developed to accurately predict the lateral earth pressure coefficient and point of application, achieving R2 values of 0.94 and 0.93, respectively. In addition, an analytical model based on Coulomb's earth pressure theory is presented and compared with ANN models. These models are anticipated to assist designers and practitioners in optimizing hunchback retaining walls for unsaturated backfill.

A Method for Mapping Semi-Diagonal of Intra Prediction to Edge Information of MPEG-7 EHD (인트라 예측의 Semi-Diagonal을 EHD 에지 정보로 맵핑하는 방법)

  • Kwon, Yong-Kwang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.87-88
    • /
    • 2012
  • Because intra prediction modes in H.264 are determined by the brightness continuity between neighboring blocks, they can be used as a method for extracting edge information in the compression domain. However, if we just consider 9 intra prediction modes in H.264 as 9 different edge directions, we have the following two problems. First, intra prediction modes tend to yield too many edge blocks, generating unnecessary edge information. Second, we may not need all 9 directional edges (including the DC type) in H.264 intra prediction modes. For example, the EHD (edge histogram descriptor) in MPEG-7 defines only 4 directional edge types, namely horizontal, vertical, diagonal (HVD) edges with $0^{\circ}$, $90^{\circ}$, $45^{\circ}$, and $135^{\circ}$. Here, semi-diagonal (SD) edge types with $112.5^{\circ}$, $157.5^{\circ}$, $22.5^{\circ}$, and $67.5^{\circ}$ in the intra prediction modes in H.264 are not used. In this paper. we prepose a method that removes unnecessary edges from the intra prediction modes by utilizing the total average coefficient of 4x4 blocks in each slice and assign SD edges to HVD (horizontal, vertical, diagonal, $0^{\circ}$, $90^{\circ}$, $45^{\circ}$, $135^{\circ}$) edges by the contextual information of the neighboring blocks. Experimental results show that the edges determined by the proposed method in the compression domain are comparable to those of the previous edge detection methods in the spatial domain.

  • PDF

Prostate Object Extraction in Ultrasound Volume Using Wavelet Transform (초음파 볼륨에서 웨이브렛 변환을 이용한 전립선 객체 추출)

  • Oh Jong-Hwan;Kim Sang-Hyun;Kim Nam-Chul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.67-77
    • /
    • 2006
  • This thesis proposes an effi챠ent method for extracting a prostate volume from 3D ultrasound image by using wavelet transform and SVM classification. In the proposed method, a modulus image for each 2D slice is generated by averaging detail images of horizontal and vertical orientations at several scales, which has the sharpest local maxima and the lowest noise power compared to those of all single scales. Prostate contour vertices are determined accurately using a SVM classifier, where feature vectors are composed of intensity and texture moments investigated along radial lines. Experimental results show that the proposed method yields absolute mean distance of on average 1.89 pixels when the contours obtained manually by an expert are used as reference data.

A new analytical approach to estimate the seismic tensile force of geosynthetic reinforcement respect to the uniform surcharge of slopes

  • Motlagh, Ali Tafreshi;Ghanbari, Ali;Maedeh, Pouyan Abbasi;Wu, Wei
    • Earthquakes and Structures
    • /
    • v.15 no.6
    • /
    • pp.687-699
    • /
    • 2018
  • This paper investigates the pseudo-static analysis of reinforced slopes with geosynthetics under the influence of the uniform surcharge to evaluate the maximum tensile force of reinforcements. The analytical approach has basically been used to develop the new practical procedure to estimate both tensile force and its distribution in the height of the slope. The base of developed relationships has been adapted from the conventional horizontal slice method. The limit equilibrium framework and the assumptions of log-spiral failure surface have directly been used for proposed analytical approach. A new analytical approach considering a single layer of non-cohesion soil and the influence of uniform surcharge has been extracted from the 5n equation and 5n unknown parameters. Results of the proposed method illustrated that the location of the surcharge, amount of internal friction and the seismic coefficient have the remarkable effect on the tensile force of reinforcement and might be 2 times increasing on it. Furthermore, outcomes show that the amount of tensile force has directly until 2 times related to the amount of slope angle and its height range. Likewise, it is observed that the highest value of the tensile force in case of slope degree more than 60-degree is observed on the lower layers. While in case of less degree the highest amount of tensile force has been reported on the middle layers and extremely depended to the seismic coefficient. Hence, it has been shown that the tensile force has increased more than 6 times compared with the static condition. The obtained results of the developed procedure were compared with the outcomes of the previous research. A good agreement has been illustrated between the amount results of developed relationships and outcomes of previous research. Maximum 20 and 25 percent difference have been reported in cases of static and seismic condition respectively.

Three Dimensional MRI and Software for Studying Normal Anatomical Structures of an Entire Body (온몸의 정상 해부구조물을 익히기 위한 3차원 자기공명영상 및 소프트웨어)

  • Lee, Yong-Sook;Park, Jin-Seo;Hwang, Sung-Bae;Cho, Jae-Hyun;Chung, Min-Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.117-133
    • /
    • 2005
  • For identifying the pathological findings in magnetic resonance images (MRIs), normal anatomical structures in MRIs should be identified in advance. For studying the anatomical structures in MRIs, a learning tool that includes the followings is necessary. First, MRIs of the entire body; second, horizontal, coronal, and sagittal MRIs; third, segmented images corresponding to the MRIs; fourth, three dimensional (3D) images of the anatomical structures in the MRIs; fifth, software incorporating the MRIs, segmented images, and 3D images. Such a learning tool, however, is hard to obtain. Therefore, in this research, such a learning tool which helps medical students and doctors study the normal anatomical structures in MRIs was made as follows. A healthy young Korean male adult with standard body shape was selected. Six hundred thirteen MRIs of the entire body were scanned (slice thickness 3 mm, interslice gap 0 mm, field of view 480 mm${\times}$480 mm, resolution 512${\times}$512, T1 weighted), and transferred to the personal computer. Sixty anatomical structures in the MRIs were segmented to make segmented images. Coronal, sagittal MRIs and coronal, sagittal segmented images were made. On the basis of the segmented images, forty-seven anatomical structures 3D images were made by manual surface reconstruction method. Software incorporating the MRIs, segmented images, and 3D images was composed. This learning tool that includes horizontal, coronal, sagittal MRIs of the entire body, corresponding segmented images, 3D images of the anatomical structures in the MRIs, and software is expected to help medical students and doctors study the normal anatomical structures in MRIs. This learning tool will be presented worldwide through Internet or CD titles.

  • PDF

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF