• 제목/요약/키워드: horizontal shear strength

검색결과 242건 처리시간 0.023초

패널파괴형 철골 커플링 보-벽체 접합부의 내진거동 (Seismic Behavior of Steel Coupling Beam-Wall Connection with Pane Shear Failure)

  • 박완신;한민기;김선우;황선경;양일승;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.431-434
    • /
    • 2005
  • In the past decade, various experimental programmes were undertaken to address the lack of information on the interaction between steel coupling beams and reinforced concrete shear wall in a hybrid coupled shear wall system. In this paper, the seismic performance of steel coupling beam-wall connections in a hybrid coupled shear wall system is examined through results of an experimental research programme where three 2/3-scale specimens were tested under cyclic loading. The test variables included the reinforcement details that confer a ductile behaviour on the steel coupling beam-wall connection, i.e., the face bearing plates and the horizontal ties in the panel region of steel coupling beam-wall connections. Panel shear strength reflects enhancement achieved through mobilization of the reinforced concrete panel using face bearing plates and/or horizontal ties in the panel region of steel coupling beam-wall connections.

  • PDF

프리스트레스트 중공 슬래브와 현장타설된 토핑콘크리트의 수평전단성능 평가 (Evaluation of Horizontal Shear Strength of Prestressed Hollow-Core Slabs with Cast-in-Place Topping Concrete)

  • 임주혁;박민국;이득행;서수연;김강수
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.741-749
    • /
    • 2014
  • 프리스트레스트 중공(PHC) 슬래브는 장경간에 적합하도록 경량화된 효율적인 프리캐스트 부재이며, 국내 외에서 많이 사용되고 있다. 특히, 국내에서는 현장타설콘크리트와 같이 사용되는 합성슬래브 형태로 주로 적용되고 있다. 그러나, 압출성형방식으로 제작되는 PHC 슬래브 부재는 매우 낮은 슬럼프의 콘크리트로 제작되어 타설 직후에도 표면경도가 높기 때문에 계면의 거친면 처리 및 전단연결재 배치가 어려운 단점이 있다. 이 연구에서는 PHC slab 부재와 토핑콘크리트 사이의 합성성능을 고찰하기 위하여 다양한 계면상태를 변수로 직접전단실험을 수행하였으며, 기존 실험결과를 수집하여 국내 외 수평전단강도 설계기준을 평가하였다.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Investigation of pipe shear connectors using push out test

  • Nasrollahi, Saeed;Maleki, Shervin;Shariati, Mahdi;Marto, Aminaton;Khorami, Majid
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.537-543
    • /
    • 2018
  • Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity.

Deflection prediction for reinforced concrete deep beams

  • Lu, Wen-Yao;Hwang, Shyh-Jiann;Lin, Ing-Jaung
    • Computers and Concrete
    • /
    • 제7권1호
    • /
    • pp.1-16
    • /
    • 2010
  • A simplified method, developed from the softened strut-and-tie model, for determining the mid-span deflection of deep beams at ultimate state is proposed. The mid-span deflection and shear strength predictions of the proposed model are compared with the experimental data collected from 70 simply supported reinforced concrete deep beams, loaded with concentrated loads located at a distance a from an end reaction. The comparison shows that the proposed model can accurately predict the mid-span deflection and shear strength of deep beams with different shear span-to-depth ratios, different concrete strengths, and different horizontal and vertical hoops.

프리캐스트 바닥판 PSC 합성거더 교량의 거동 (Behavior of PSC Composite Bridge with Precast Decks)

  • 정철헌;현병학
    • 대한토목학회논문집
    • /
    • 제26권5A호
    • /
    • pp.873-880
    • /
    • 2006
  • 본 논문에서는 기존의 수평전단 설계식을 적용하여 프리캐스트 바닥판 PSC 합성거더 교량을 설계, 제작하였다. 피로하중에 대한 바닥판과 거더 그리고 전단연결부의 내구성과 거동특성을 평가하기 위하여 피로실험을 수행하였다. 실험결과 200만회 반복하중을 재하한 후 바닥판과 거더의 균열 및 잔류처짐은 발생하지 않았으며, 휨강성의 감소없이 선형거동을 나타냈다. 그리고 전단연결부의 손상은 나타나지 않았다. 또한 정적실험을 수행하여 연결부의 거동과 설계식의 적용성을 평가하고, 극한하중 상태에서의 구조적 성능과 정적강도 등을 평가하였다. 프리캐스트 바닥판 PSC 합성거더 교량은 사용하중상태에서 균열에 대해 2.08의 안전율을 나타냈으며, 파괴 시 충분한 극한내력과 연성거동을 나타냈다. 수평전단 설계식을 프리캐스트 바닥판 PSC 합성거더 교량의 수평전단 설계에 적용할 경우 사용성 및 구조적 안전성에 문제가 없는 경제적이고 신속한 형태의 교량을 시공할 수 있을 것으로 판단된다.

철근콘크리트 전단벽의 접합방식과 대각보강에 따른 내진성능 평가 및 개선 (Improvement and Evaluation for Seismic Resistant Capacity of Reinforced Concrete Shear wall with Connection Types and Diagonal Reinforcement)

  • 신종학;하기주;안준석;주정준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.139-147
    • /
    • 1999
  • Six reinforced concrete shear wall, constructured with fully rigid, slit, and infilled types, were tested under both vertical and cyclic loadings. Experimental programs were carried out to evaluate the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility, under load reversals. All the specimens were modeled in one-third scale size. Based on the test results, the following conclusions can be made. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crushing due to slippage prevention of boundary region and reduction of diagonal tension rathar than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by l.14 times and l.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 관한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads)

  • 이진섭;김상식
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.191-200
    • /
    • 1999
  • 집중하중을 받는 단순지지 철근콘크리트 깊은 보를 대상으로 콘크리트의 압축강도, 전단스팬비, 웨브 수직 및 수평 보강철근비를 변수로 하여 깊은 보의 구조거동과 전단강도를 실험적으로 조사하였으며, 각 변수의 영향을 고찰하고 규준식 및 제안식 등과 비교, 검토하였다. 42개의 시험체를 실험한 결과, 모든 시험체는 전단스팬 내에서 콘크리트의 과도한 균열 및 압괴에 의해 파괴되었고, 시험체의 초기강성은 압축강도에 관계없이 전단 스팬비가 작을수록 크게 나타났으며, 경사균열 발생 이후 보의 강성이 점진적으로 감소되었다. 전단스팬비가 증가함에 따라 경사균열 및 최대하중은 일정하게 감소하며, 콘크리트 압축강도가 증가할수록 최대하중은 증가하나 경사균열 하중은 거의 변화가 없었고, 전단스팬비의 증가에 따라 콘크리트의 압축강도가 전단강도에 미치는 영향 또한 일정하게 감소하는 것으로 보인다. 웨브의 전단보강근 효과는 전단스팬비의 영향을 받으며, 전단스팬비가 작아지면 수평보강근의 효과가, 전단스팬비가 커지면 수직보강근의 효과가 상대적으로 커짐을 알 수 있었다. 실험결과와 비교하여, 이론식은 de Paiva의 제안식이, 규준식은 CIRIA guide가 실험결과에 가장 부합하는 것으로 나타났으며, 국내 규준식은 실험값에 비해 상당히 낮은 강도로 계산되고 있어 안전 측에 있는 것으로 판단된다.

강판 형상비 및 판폭두께비에 따른 강판전단벽의 변형모드 및 이력특성 (Hysteretic Characteristics and Deformation Modes of Steel Plate Shear Walls According to Aspect Ratios and Width-to-Thickness Ratios)

  • 신동현
    • 한국공간구조학회논문집
    • /
    • 제24권1호
    • /
    • pp.37-45
    • /
    • 2024
  • Steel plate shear walls (SPSWs) have been recognized as an effective seismic-force resisting systems due to their excellent strength and stiffness characteristics. The infill steel plate in a SPSW is constrained by a boundary frame consisting of vertical and horizontal structural members. The main purpose of this study was to investigate deformation modes and hysteretic characteristics of steel plate shear walls (SPSWs) to consider the effects of their aspect ratios and width-to-thicness ratios. The finite element model (FEM) was establish in order to simulate cyclic responses of SPSWs which have the two-side clamped boundary condition and made of conventional steel grade. The stress distribution obtained from the FEA results demonstrated that the principal stresses on steel plate with large thickness-to-width ratio were more uniformly distributed along its horizontal cross section due to the formation of multiple struts.

Tests of reinforced concrete deep beams

  • Lu, Wen-Yao;Hsiao, Hsin-Tai;Chen, Chun-Liang;Huang, Shu-Min;Lin, Ming-Che
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.357-372
    • /
    • 2015
  • This study reports the test results of twelve reinforced concrete deep beams. The deep beams were tested with loads applied through and supported by columns. The main variables studied were the shear span-to-depth ratios, and the horizontal and vertical stirrups. The shear strengths can be effectively enhanced for deep beams reinforced with both horizontal and vertical stirrups. The test results indicate the shear strengths of deep beams increase with the decrease of the shear span-to-depth ratios. The normalized shear strengths of the deep beams did not increase proportionally with an increase in effective depth. An analytical method for predicting the shear strengths of deep beams is proposed in this study. The shear strengths predicted by the proposed method and the strut-and-tie model of the ACI Code are compared with available test results. The comparison shows the proposed method can predict the shear strengths of reinforced concrete deep beams more accurately than the strut-and-tie model of the ACI Code.