• Title/Summary/Keyword: horizontal shear resistance

Search Result 67, Processing Time 0.022 seconds

An Experimental Study on the Shear Resistance of Horizontal Shear Reinforcement in R.C. Deep Beams (철근콘크리트 깊은 보에서 수평 전단철근의 전단저항에 관한 실험적 연구)

  • 양근혁;이영호;은희창;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.903-906
    • /
    • 2001
  • The objective of this experimental study was to understand the effect of horizontal shear bar on the shear behavior of R.C. deep beams. Therefore, in the test program, the horizontal shear bar ratio($\rho_{sh}$) and shear span-to-overall depth ratio(a/h) are considered as two main variables. Test results indicate that for deep beams with a/h equal to 1.0, horizontal shear bar is less efficient in restricting the diagonal crack width development and enhancing the ultimate shear strength. So, it can be concluded that shear resistance of horizontal shear bar is related to a/h rather than clear span-to-effective depth ratio($l_{n}$/d) recommended in ACI code.

  • PDF

An Experimental Study on the Shear Resistance of Horizontal Joints in Precast Concrete Large Panel Structures (대형판 프리캐스트 콘크리트 구조 수평접합부의 전단내력에 대한 실험적 연구)

  • 정창용;현원창;엄철환;어양석;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.208-213
    • /
    • 1992
  • This research is related to the experimental verification of the shear resistance of horizontal joint in precast concrete large panel structures. a total of 9 spicemens was tested to assess their shear resistance. In the tests lateral forces have been applied to the specimen to cause shear failure while keeping the axial compression consistantly. The shear resistances of the specimens have been evaluated by investigating the deformations and failure modes of the specimens. From the test results, it is observed that the shear resistance of the horizontal joints of P.C panel structures are closely connected with shear friction mechanism.

  • PDF

Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths (전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동)

  • Kim, Tae-Hyup;Park, Jun-Myung;Hong, Sung-Nam;Park, Sun-Kyu;Kim, Hyeong-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2007
  • Recently, steel-concrete composite structures are widely used in bridge and building constructions. In this paper, a new type of steel-concrete composite deck with profiled steel sheeting is proposed to replace the conventional cast-in-place reinforced concrete deck. Perfobond rib shear connectors were utilized to provide horizontal shear resistance between the profiled sheeting and the concrete. To validate the effectiveness of the proposed deck system, 8 full-scale deck specimens for PSC girder bridge were fabricated. The specimens were tested with four different shear span lengths to determine the horizontal shear resistance of the deck under a static monotonic loading. For comparison purpose, two reinforced concrete decks were also fabricated and tested. The horizontal shear resistance of the proposed deck system was calculated using the m-k method.

The Relationships Between Shear Reinforcement Ratios and Shear Strength in Reinforced Concrete Deep Beams (철근콘크리트 깊은 보에서 전단철근비와 전단내력의 관계)

  • Yang Keun-Hyeok;Park Jeong-Hwa;Chung Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.256-259
    • /
    • 2004
  • The objective of this experimental study is to understand the effects of horizontal and vertical shear reinforcement on the shear strength of concrete deep beams. Main variables were the horizontal shear reinforcement ratio $(P_{sh})$, vertical shear reinforcement ratio$(P_{sv})$ and shear span-to-overall depth ratio(a/h). Test results revealed that the effectiveness of shear resistance of shear reinforcement was greatly related to the a/h. For the beams with $a/h\geq1.0$, the vertical shear reinforcement was more effective than horizontal shear reinforcement.

  • PDF

Effect of Glass Fiber-Reinforced Connection on the Horizontal Shear Strength of CLT Walls

  • JUNG, Hongju;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.685-695
    • /
    • 2020
  • The connection performance between cross-laminated timber (CLT) walls and support has the greatest effect on the horizontal shear strength. In this study, the horizontal shear performance of CLT walls with reinforced connection systems was evaluated. The reinforcements of metal bracket connections in the CLT connection system was made by attaching glass fiber-based reinforcement to the connection zone of a CLT core lamina. Three types of glass fiber-based reinforcement were used: glass fiber sheet (GS), glass fiber cloth (GT) and fiber cloth plastic (GTS). The horizontal shear strength of the fabricated wall specimens was compared and evaluated through monotonic and cyclic tests. The test results showed that the resistance performance of the reinforced CLT walls to a horizontal load based on a monotonic test did not improve significantly. The residual and yield strengths under the cyclic loading test were 38 and 18% higher, respectively, while the ductility ratio was 38% higher than that of the unreinforced CLT wall. The glass fiber-based reinforcement of the CLT connection showed the possibility of improving the horizontal shear strength performance under a cyclic load, and presented the research direction for the application of real-scale CLT walls.

Development of Device to Resist Horizontal Displacement of Asphalt Concrete Track (아스팔트콘크리트 궤도용 궤도변위 저항 장치 개발)

  • Lee, Seonghyeok;Yoon, Wooyong;Bae, Younghoon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.744-754
    • /
    • 2016
  • Asphalt concrete track (ACT) is a track system connecting wide sleepers and concrete panels on top of an asphalt concrete layer; such a system requires adequate resistance force against various longitudinal and lateral external loads. In this study, a series of experiments were carried out to assess the longitudinal and lateral resistance force of a wide sleeper and concrete panel type ACT. The required shear resistance force of the horizontal displacement restraint device (HDRD) was evaluated. Furthermore, a concrete block type anchor and a steel pipe type anchor were developed as HDRDs. The shear resistance force was decided based on the experimental results of horizontal shear tests for each anchor system. In addition, proper numbers and arrangement design guidelines for the HDRDs were suggested considering the shear resisting capacity and economics for HDRDs applied to ACT.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Shear resistance behaviors of a newly puzzle shape of crestbond rib shear connector: An experimental study

  • Chu, Thi Hai Vinh;Bui, Duc Vinh;Le, Van Phuoc Nhan;Kim, In-Tae;Ahn, Jin-Hee;Dao, Duy Kien
    • Steel and Composite Structures
    • /
    • v.21 no.5
    • /
    • pp.1157-1182
    • /
    • 2016
  • A newly puzzle shape of crestbond rib shear connector is a type of ductile perfobond rib shear connector. This shear connector has some advantages, including relatively easy rebar installation and cutting, as well as the higher shear resistance strength. Thus, this study proposed a newly puzzle shape of crestbond rib with a "${\mho}$" shape, and its shear resistance behaviors and shear strengths were examined using push-out tests. Five main parameters were considered in the push-out specimens to evaluate the effects of shear resistance parameters such as the dimensions of the crestbond rib, transverse rebars in the crestbond dowel, concrete strength, rebar strength, and dowel action on the shear strength. The shear loading test results were used to compare the changes in the shear behaviors, failure modes, and shear strengths. It was found that the concrete strength and number of transverse rebars in the crestbond rib were significantly related to its shear resistance. After the initial bearing resistance behavior of the concrete dowel, a relative slip occurred in all the specimens. However, its rigid behavior to shear loading decreased the ductility of the shear connection. The cross-sectional area of the crestbond rib was also shown to have a minor effect on the shear resistance of the crestbond rib shear connector. The failure mechanism of the crestbond rib shear connector was complex, and included compression, shear, and tension. As a failure mode, a crack was initiated in the middle of the concrete slab in a vertical direction, and propagated with increasing shear load. Then, horizontal cracks occurred and propagated to the front and rear faces of the specimens. Based on the results of this study, a design shear strength equation was proposed and compared with previously suggested equations.

Horizontal stiffness solutions for unbonded fiber reinforced elastomeric bearings

  • Toopchi-Nezhad, H.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.3
    • /
    • pp.395-410
    • /
    • 2014
  • Fiber Reinforced Elastomeric Bearings (FREBs) are a relatively new type of laminated bearings that can be used as seismic/vibration isolators or bridge bearings. In an unbonded (U)-FREB, the bearing is placed between the top and bottom supports with no bonding or fastening provided at its contact surfaces. Under shear loads the top and bottom faces of a U-FREB roll off the contact supports and the bearing exhibits rollover deformation. As a result of rollover deformation, the horizontal response characteristics of U-FREBs are significantly different than conventional elastomeric bearings that are employed in bonded application. Current literature lacks an efficient analytical horizontal stiffness solution for this type of bearings. This paper presents two simplified analytical models for horizontal stiffness evaluation of U-FREBs. Both models assume that the resistance to shear loads is only provided by an effective region of the bearing that sustains significant shear strains. The presented models are different in the way they relate this effective region to the horizontal bearing displacements. In comparison with experimental results and finite element analyses, the analytical models that are presented in this paper are found to be sufficiently accurate to be used in the preliminary design of U-FREBs.

Experimental Study on Structural Behavior of Interfaces of Double Composite Girder Using the 80 MPa Concrete (80 MPa급 콘크리트를 활용한 이중합성 거더의 수평접합면 구조거동에 관한 실험적 연구)

  • Yang, In-Wook;Lim, Eol;Ha, Tae-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.400-413
    • /
    • 2016
  • The horizontal shear capacity when the flange of a steel girder is replaced with 80 MPa concrete is important for its structural safety. In this study, 6 specimens with different interface conditions were designed and fabricated based on the Limit State Design Code on Korean Highway Bridges and static tests were performed to measure the horizontal shear capacity. Not only the resistance factors of the stud shear connector, concrete and reinforcement, but also the surface conditions of the casing concrete and spacing of the horizontal shear reinforcements were used as the experimental variables. The experiments showed that the interfaces between the steel girder and the concrete flange have stronger joint performance than those between the concrete flange and deck slab. To ensure the composite action in the plastic zone, the conservative horizontal shear reinforcement is more important than the roughness in the concrete face.