• 제목/요약/키워드: horizontal seismic coefficient

Search Result 40, Processing Time 0.021 seconds

Seismic Loading Requirements for Singapore Buildings

  • Pan, Tso-Chien
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.87-98
    • /
    • 1998
  • In this paper, the potential ground motion in terms of the peak ground accelerations(PGAs) due to long-distance Sumatra earthquakes is investigated for Singapore, following the probabilistic seismic hazard assessment a, pp.oach. The case investigated differs from a conventional one, in that few attenuation equations for long-distance major earthquakes are readily available. The attenuation relationships developed for other regions of the world are thus reviewed. It is found that the existing attenuation equations, when extrapolated to distant major earthquakes, tend to underestimate the PGAs. By comparing with the PGAs recorded over long distances at stations of the Japanese Meteorological Agency for major earthquakes in Japan, an attenuation equation is chosen for this study. With the chosen attenuation equation, the probability of PGAs exceeding selected levels for various exposure periods of time is then computed. The results show that at Singapore there is a 10% probability in 50 years for the PGA at rock sites to exceed 1.1% g. In view of the results and the associated uncertainties, a base shear coefficient of 1.5% is being recommended as the tentative seismic loading in Singapore. The tentative seismic loading reflects the design value of the notional horizontal load, equal to 1.5% of the characteristic building weigh as specified in the BS code, which usualy governs the design of most buildings in Singapors.

  • PDF

Estimation of amplification of slope via 1-D site response analysis (1차원 지반응답해석을 통한 사면의 증폭특성 규명)

  • Yun, Se-Ung;Park, Du-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.620-625
    • /
    • 2009
  • The seismic slope stability is most often evaluated by the pseudo-static limit analysis, in which the earthquake loading is simplified as static inertial loads acting in horizontal and/or vertical directions. The transient loading is represented by constant acceleration via the pseudostatic coefficients. The result of a pseudostatic analysis is governed by the selection of the value of the pseudostatic coefficient. However, selection of the value is very difficult and often done in an ad hoc manner without a sound physical reasoning. In addition, the maximum acceleration is commonly estimated from the design guideline, which cannot accurately estimate the dynamic response of a slope. There is a need to perform a 2D dynamic analysis to properly define the dynamic response characteristics. This paper develops the modified one-dimensional seismic site response analysis. The modified site response analysis adjusts the density of the layers to simulate the change in mass and weight of the layers of the slope with depth. Multiple analyses are performed at various locations within the slope to estimate the change in seismic response of the slope. The calculated peak acceleration profiles with depth from the developed procedure are compared to those by the two-dimensional analyses. Comparisons show that the two methods result in remarkable match.

  • PDF

Seismic responses of a free-standing two-story steel moment frame equipped with a cast iron-mortar sliding base

  • Chung, Yu-Lin;Kuo, Kuan-Ting;Nagae, Takuya;Kajiwara, Koichi
    • Earthquakes and Structures
    • /
    • v.17 no.3
    • /
    • pp.245-256
    • /
    • 2019
  • An experimental study was conducted to evaluate the dynamic behavior of a free-standing frame equipped with a movable base system using cast iron and mortar as the bearing materials. The preliminary friction test indicated that a graphite layer developed on the interface and exhibited stable friction behavior. The friction coefficient ranged from 0.33 to 0.36 when the applied normal compression stress ranged from 2.6 to 5.2 MPa. The effect of the variation of normal compression stress would be small. Shaking table tests on the free-standing frame showed that rock, slide, and rock-slide responses occurred. The cumulative slide distance reached 381 mm under JMA Kobe wave excitation; however, only a few cyclic slides occurred at the same locations along the moving track. Most surfaces sustained single slides. Similar results can be observed in other shaking conditions. The insufficient cyclic sliding and significant rocking resulted in a few graphite layers on the mortar surfaces. Friction coefficients were generally similar to those obtained in the preliminary friction tests; however, the values fluctuated when the rocking became significant. The collisions due to rocking caused strong horizontal acceleration responses and resulted in high friction coefficient. In addition, the strong horizontal acceleration responses caused by the collisions made the freestanding specimen unable to reduce the input horizontal acceleration notably, even when slippage occurred. Compared with the counterpart fixed-base specimen, the specimen equipped with the iron-mortar base could reduce the horizontal acceleration amplification response and the structural deformation, whereas the vertical acceleration response was doubled due to collisions from rocking.

A new analytical approach to estimate the seismic tensile force of geosynthetic reinforcement respect to the uniform surcharge of slopes

  • Motlagh, Ali Tafreshi;Ghanbari, Ali;Maedeh, Pouyan Abbasi;Wu, Wei
    • Earthquakes and Structures
    • /
    • v.15 no.6
    • /
    • pp.687-699
    • /
    • 2018
  • This paper investigates the pseudo-static analysis of reinforced slopes with geosynthetics under the influence of the uniform surcharge to evaluate the maximum tensile force of reinforcements. The analytical approach has basically been used to develop the new practical procedure to estimate both tensile force and its distribution in the height of the slope. The base of developed relationships has been adapted from the conventional horizontal slice method. The limit equilibrium framework and the assumptions of log-spiral failure surface have directly been used for proposed analytical approach. A new analytical approach considering a single layer of non-cohesion soil and the influence of uniform surcharge has been extracted from the 5n equation and 5n unknown parameters. Results of the proposed method illustrated that the location of the surcharge, amount of internal friction and the seismic coefficient have the remarkable effect on the tensile force of reinforcement and might be 2 times increasing on it. Furthermore, outcomes show that the amount of tensile force has directly until 2 times related to the amount of slope angle and its height range. Likewise, it is observed that the highest value of the tensile force in case of slope degree more than 60-degree is observed on the lower layers. While in case of less degree the highest amount of tensile force has been reported on the middle layers and extremely depended to the seismic coefficient. Hence, it has been shown that the tensile force has increased more than 6 times compared with the static condition. The obtained results of the developed procedure were compared with the outcomes of the previous research. A good agreement has been illustrated between the amount results of developed relationships and outcomes of previous research. Maximum 20 and 25 percent difference have been reported in cases of static and seismic condition respectively.

Dynamic Factor of Safety Calculation of Slope by Nonlinear Response History Analysis (비선형 응답이력해석을 통한 사면의 동적 안전계수 계산)

  • Lee, Yonghee;Kim, Hak-Sung;Ju, Young-Tae;Kim, Daehyeon;Park, Heon-Joon;Park, Duhee
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.9
    • /
    • pp.5-12
    • /
    • 2021
  • Pseudo-static slope stability analysis method is widely used in engineering practice to calculate the seismic factor of safety of slope subjected to earthquake ground motions. Although the dynamic analysis method is well recognized to have the primary advantage of simulating the stress-strain response of soils, it is not often used in practice because of the difficult in estimating the factor of safety. In this study, a procedure which utilizes the dynamic analysis method to extract the transient dynamic factor of safety is devleoped. This method overcomes the major limitation of the pseudo-static method, which uses an empirically determined seismic coefficient to derive the factor of safety. The proposed method is applied to a slope model and the result is compared with that of the pseudo-static method. It is shown that minimum dynamic factor of safety calculated by the dynamic analysis is slightly larger than that determined from the pseudo-static method. It is also demonstrated that the dynamic factor of safety becomes minimum when the horizontal seismic coefficient and horizontal average acceleration are maximum.

Seismic Performance-Based Design for Breakwater (방파제의 성능기반 내진설계법)

  • Kim, Young-Jun;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.91-101
    • /
    • 2022
  • The 1995 Kobe earthquake caused a massive damage to the Port of Kobe. Therefore, it was pointed out that it was impossible to design port structures for Level II (Mw 6.5) earthquakes with quasi-static analysis and Allowable Stress Design methods. In Japan and the United States, where earthquakes are frequent, the most advanced design standards for port facilities are introduced and applied, and the existing seismic design standards have been converted to performance-based design. Since 1999, the Korean Port Seismic Design Act has established a definition of necessary facilities and seismic grades through research on facilities that require seismic design and their seismic grades. It has also established a performance-based seismic design method based on experimental verification. In the performance-based seismic design method of the breakwater proposed in this study, the acceleration time history on the surface of the original ground was subjected to a fast Fourier transform, followed by a filter processing that corrected the frequency characteristics corresponding to the maximum allowable displacement with respect to performance level of the breakwater and the filtered spectrum. The horizontal seismic coefficient for the equivalent static analysis considering the displacement was calculated by inversely transforming (i.e., subjected to an inverse fast Fourier transform) into the acceleration time history and obtaining the maximum acceleration value. In addition, experiments and numerical analysis were performed to verify the performance-based seismic design method of breakwaters suitable for domestic earthquake levels.

Seismic behavior of reinforced concrete T-shaped columns under compression-bending-shear and torsion

  • Ping, Chen Zong;Weiwei, Su;Yang, Yang
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.431-444
    • /
    • 2021
  • T-shaped column is usually used as side column in buildings, which is one of the weak members in structural system. This paper presented a quasi-static cyclic loading experiment of six specimens of reinforced concrete (RC) T-shaped columns under compression-flexure-shear-torsion combined loadings to investigate the effect in the ratio of torsion to moment (T/M) and axial compression ratio (n) and height-thickness ratio of flange plate (φ) on their seismic performance. Based on the test results, the failure characteristics, hysteretic curves, ductility, energy dissipation, stiffness degradation and strength degradation were analyzed. The results show that the failure characteristics of RC T-shaped columns mainly depend on the ratio of torsion to moment, which can be divided into bending failure, bending-torsion failure and shear-torsion failure. With the increase of T/M ratio, the torsion ductility coefficient increased, and in a suitable range, the torsion and horizontal displacement ductility coefficient of RC T-shaped columns could be effectively improved with the increase of axial compression ratio and the decrease of height-thickness ratio of flange plate. Besides, the energy dissipation capacity of the specimens mainly depended on the bending and shear energy dissipation capacity. On the other hand, the increase of axial compression ratio and the ratio of torsion to moment could accelerate the torsional and bending stiffness degradation of RC T-shaped columns. Moreover, the degradation coefficient of torsion strength was between 0.80 and 0.98, and that of bending strength was between 0.75 and 1.00.

Study of seismic traveltime and amplitude effect to detect to detect cracks in rock (암석시편의 균열조사를 위한 탄성파 주시 및 진폭 변화에 관한 연구)

  • 서백수;백환조;민경원
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.239-244
    • /
    • 1996
  • Cracks have influence on the physical and mechanical and, more importantly, on the engineering properties of the rock. Physical properties including the volumetric deformation coefficient, electrical resistivity, seismic wave velocity, and the mechanical properties such as the elastic constants and strength of rock are affected significantly by the presence of cracks of various sizes. An experimental program was undertaken to investigate the effect of a finite line crack on the diffraction of the plane compressional wave. Horizontal and vertical components of displacement and acceleration curve were obtained using a single-source and multi-receivers system. A theoretical model from numerical analysis implementing the finite element method was compared with the measured data.

  • PDF

Analysis of Seismic Performance of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내진성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.409-416
    • /
    • 2020
  • The seismic performance of a containment structure should be secured to maintain the structural soundness of a containment structure under various earthquakes that occur globally. Therefore, an analysis of the seismic performance of a modular containment structure for a small modular reactor is also required. To analyze the seismic performance of modular containment, FEM models with contact surfaces between the modules and tendon were prepared and the modal and seismic analyses were performed. The displacement, stress, and gap size of modular containment under earthquake wave were analyzed. The effects of the tendon force, friction coefficient, and earthquake wave on the seismic performance were analyzed. The seismic performance of monolithic containment was also analyzed for comparison. In the 1st and 2nd natural modes, which most likely affect, the modular containment showed horizontal dynamic behavior, which is similar to monolithic containment, because of the combined effects of the tendon force and friction force between modules. When the combined effect is sufficient, the seismic performance of the modular containment is secured over a certain level. An additional increase in seismic performance is expected when some material with a larger friction coefficient is adopted on the contact surface.

Amplification Characteristics of Domestic and Overseas Intraplate Earthquake Ground Motions in Korean Soil and Standard Horizontal Design Spectrum for Soil Sites (국내외 판내부 지진기록을 사용한 국내 지반의 지반운동 증폭특성 규명 및 토사지반의 표준설계응답스펙트럼의 제안)

  • Lee, Jin Ho;Kim, Jung Han;Kim, Jae Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.391-399
    • /
    • 2018
  • The site coefficients in the common requirements for seismic design codes, which were promulgated in 2017, were reevaluated and the standard design spectrum for soil sites were newly proposed in order to ensure the consistency of the standard design spectra for rock and soil sites specified in the common requirements. Using the 55 ground motions from domestic and overseas intraplate earthquakes, which were used to derive the standard design spectrum for rock sites, as rock outcropping motions, site response analyses of Korean soil were performed and its ground-motion-amplification was characterized. Then, the site coefficients for soil sites were reevaluated. Compared with the existing site coefficients, the newly proposed short-period site coefficient $F_a$ increased and the long-period site coefficient $F_v$ decreased overall. A new standard design spectrum for soil sites was proposed using the reevaluated site coefficients. When compared with the existing design spectrum, it could be seen that the proposed site coefficients and the standard design spectrum for soil sites were reasonably derived. They reflected the short-period characteristics of earthquake and soil in Korea.