• Title/Summary/Keyword: horizontal electric field

Search Result 89, Processing Time 0.024 seconds

Experimental Study on Flow Characteristics of ERF by using PIV Technique (PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.116-123
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow. 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm. 1.0kV/mm and 1 5kV/mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased. the claster of ERF are clearly strong along the test tube and the flow rate decreased.

A Modeling of a Variable-damping Mount Using Magneto-Rheological Fluid (ER유체를 이용한 이방성 스퀴즈필름 댐퍼의 응답특성에 관한 연구)

  • Ahn, Young-Kong;Yang, Bo-Suk;Morishita, Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.256-261
    • /
    • 2000
  • Electro-Rheological(ER) fluid is applied to a controllable squeeze film damper(SFD) for stabilizing a flexible rotor system. ER fluid is a class of functional fluid whose yield stress varies according to the applied electric field strength, which is observed as viscosity variation of the fluid. In applying ER fluid to a SFD, a pair of rings of the damper can be used as electrodes. When the electrodes are divided into a horizontal pair and a vertical one, the SFD can produce damping force in each direction independently. A prototype of the directionally controllable SFD was constructed and its performance was experimentally and numerically investigated in the present work.

  • PDF

Numerical Modeling of a Rectangular Type Inductively Coupled Plasma System (사각형 유도 결합 플라즈마 시스템의 수치 모델링)

  • Joo, Jung-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.4
    • /
    • pp.174-180
    • /
    • 2012
  • Low pressure inductively coupled plasma characteristics of argon and oxygen are numerically simulated for a 400 mm rectangular type system with a plasma fluid model. The results showed lower power absorption profile at the corner than a circular one in a 13.56 MHz driven 1.5 turn antenna system with a drift-diffusion and quasi-neutrality assumption. Ions controlled by electric field are more non-uniform than metastables and the power absorption profile of oxygen plasma is affected by horizontal gas flow pattern to show 25% lower power absorption at the pumping flange side. Oxygen negative ions which are generated in electron collisional dissociation of oxygen molecules was calculated as 0.1% of oxygen atoms with similar spatial profile.

A Model Study on the Variation of Apparent Resistivity along with Electric Resistivity Change of Host Rock (모암(母岩)의 전기비저항(電氣比抵抗) 변화(變化)에 따른 외견비저항(外見比抵抗)의 변화양상(變化樣相)에 관(關)한 모형연구(模型硏究))

  • Min, Kyung Duck;Jun, Myoung Soon
    • Economic and Environmental Geology
    • /
    • v.13 no.3
    • /
    • pp.159-166
    • /
    • 1980
  • A model study was conducted for the investigation of apparent resistivity variation along with electric resistivity variation of host rock and dip variation of bed. Experiments were carried out for the cases of horizontal and dipping beds in a water tank by using Wenner and Schlumberger arrays and by changing salinity of water. The ratios of resistivity values of the bed to that of brine were 1 : 10, 1 : 50, 1 : 100 and 1 : 500. Natural coally-shale of $55cm{\times}35cm{\times}3.5cm$ was used as a bed for experimental model, and brine as a host rock. Equi-resistivity curves and characteristic curves were obtained for each case of the experiment. The equi-resistivity curve was drawn both on the cross section parallel to strike of bed and longitudinal section perpendicular to it. The characteristic curve was drawn on the cross section. In the case of dipping bed of different dips, the curves are parallel to the boundary of the bed in the upper part of the bed, and are inclined to the opposite direction with the same angle of the dip of bed in the lower part. We can deduce, from the equi-resistivity curves, the location, shape and dip of the bed. It is shown in the characteristic curves that when the ratio of resistivity value of bed to that of host rock increases, the slope of curves becomes steeper, location of low-resistivity zone lower, and the width of it narrower. The slope of curves also becomes steeper when dip of bed increases. We can deduce, from the characteristic curves, the ratio of resistivity values between adjacent beds. It was found out from the experiments that electric resistivity method could be applicable to prospecting for underground geology with an electric resistivity contrast of 1 : 10. This fact strongly suggests that distinction of coal from coally-shale could be possible in a certain field condition.

  • PDF

Shielding Effectiveness Analysis of the Digital Module Storage Cabinet for Nuclear Power Plants According to the Internal Structure and the Angle of EM wave Incidence (내부구조와 전파 입사각에 따른 원전용 디지털 모듈 보관 캐비닛의 차폐효과 분석)

  • Youn, Sang-Woon;Jang, Do-Young;Choo, Ho-Sung;Kim, Young-Mi;Lee, Jun-Yong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • In this paper, the cabinet shielding effectiveness (SE) including digital modules for nuclear power plants is analyzed depending on the internal structure and electromagnetic (EM) wave incidence angle. To analyze the SE, the cabinet and modules are modeled using the FEKO EM simulation tool. The SE is then obtained by comparing the electric field with and without the cabinet. In addition, the cabinet SE is observed by changing various conditions such as the spacing of each digital module, incidence angle, and the polarization of the EM wave at the 2.4 G[Hz frequency. To verify the results, the dipole antenna for SE measurements is fabricated, and the SE is measured in a semi-anechoic chamber. The result demonstrates that the SE by the cabinet structure can be expected to be higher when the polarization of the incident EM wave is horizontal to the ground and the distance between the digital modules is wide.

Gravity Field Interpretation and Underground Structure Modelling as a Method of Setting Horizontal and Vertical Zoning of a Active Fault Core (활성단층의 3차원적인 규모를 결정하기 위한 중력장 데이터의 해석 및 지각구조 모델링: 양산단층에서의 예)

  • Choi, Sungchan;Kim, Sung-Wook;Choi, Eun-Kyeong;Lee, Young-Cheol;Ha, Sangmin
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.91-103
    • /
    • 2021
  • In order to estimate the vertical and horizontal structural in the Yangsan fault core line (Naengsuri area, Pohang), we carried out gravity field measurements and interpretation procedures such as Euler deconvolution method and curvature analysis in addition to the forward modelling technique (i.e. IGMAS+). We found a prominent gravity difference of more than 1.5 mGal across the fault core. This indicates a distinct density difference between the western and eastern crustal area across the Yangsan fault line. Comparing this gravity field interpretation with other existent geologic and geophysical survey data (e.g. LiDAR, trenching, electric resistivity measurements), It is concluded that (1) the prominent gravity difference is caused by the density difference of about 0.1 g/㎤ between the Bulguksa Granite in the west and the Cretaceous Sandstone in the east side, (2) the fault core is elongated vertically into a depth of about 2,000 meters and extended horizontally 3,000 meters to the NNE direction from Naengsuri area. Our results present that the gravity field method is a very effective tool to estimate a three -dimensional image of the active fault core.

Effect of nonlinear soil-structure interaction on the seismic performance of 3D isolated transformers when scaling the response spectra using the improved wavelet method

  • Mohammad Mahmoudi;Abbas Ghasemi;Shahriar Tavousi Tafreshi
    • Structural Engineering and Mechanics
    • /
    • v.91 no.5
    • /
    • pp.469-486
    • /
    • 2024
  • Electric transformers are major components of electrical systems, and damage to them caused by earthquakes can result in significant financial loss. The current study modeled a three-dimensional (3D) isolated electrical transformer under horizontal and vertical records from different earthquakes. Instead of using fixed coefficients, an improved wavelet method has been used to create the greatest compatibility between the response spectra and the target spectrum. This method has primarily been used for dynamic analysis of isolated structures with spring-damper devices because it has shown greater accuracy in predicting the response of such structures. The effect of the nonlinear soil-structure interaction on the probability of transformer failure also has been investigated. Soil and structure interaction modeling was carried out using a beam on a nonlinear Winkler foundation. The effect of the nonlinear soil-structure interaction during dynamic analysis of transformers revealed that the greatest increase in the probability of transformer failure was in the fixed-base condition when the structure was located on soft soil. This intensified the response of the structure and increased the probability of transformer failure by up to 27% for far-field and up to 95% for near-field ground motions. A comparison of the results indicates that the use of 3D isolation systems in transformers in areas with soft clay that are subject to near-field ground motions can strongly reduce the probability of failure and improve the seismic performance of the transformer.

Single cell gap polymer-stabilized blue-phase transflective LCDs using internal nanowire grid polarizer

  • Cui, Hong-Qing;Ye, Zhi-Cheng;Hu, Wei;Lin, Xiao Wen;Chung, T.C.;Jen, Tean-Sen;Lu, Yan-Qing
    • Journal of Information Display
    • /
    • v.12 no.3
    • /
    • pp.115-119
    • /
    • 2011
  • Optically isotropic liquid crystal (LC) mixture such as blue-phase LC and nanostructured LC composites exhibit the advantages of fast response time, high contrast ratio and wide-viewing angle due to the induced birefringence along the horizontal electric field. Utilizing this mixture, a novel single cell gap in-plane switching-type polymer-stabilized blue-phase transflective liquid crystal display by embedding the nanowire grid polarizer as a polarization-dependent reflective polarizer in the R region is proposed. This device can be used as a normal black mode without any quarter-wave plate or patterned in-cell phase retarder. Moreover, the transmittance is identical to the reflectance so that it will be suitable for single gamma driving. Detailed electro-optic performances, such as voltage-dependent light efficiency and viewing angle of the proposed device configuration, are investigated.

New and Improved Time-selective Self-triggering Water Sampler: AUTTLE

  • Jin, Jae-Youll;Hwang, Kuen-Choon;Park, Jin-Soon;Eo, Young-Sang;Kim, Seong-Eun;Yum, Ki-Dai;Oh, Jae-Kyung
    • Ocean and Polar Research
    • /
    • v.22 no.2
    • /
    • pp.57-67
    • /
    • 2000
  • Time-selective self-triggering water sampler, AUTTLE developed by Jin et al. (1999) has been improved in order to prevent pre-deposition of suspended sediments (SS) before sampling. By using two solenoids, the improved sampler is able to be moored or deployed with inclination. Its position is changed to horizontal position by activating the first solenoid, and then the endcaps of the sampling bottle are closed by the second solenoid that is driven three times to minimize possible failure of sampling. An external control unit for setting sampling time has been also constructed. Additionally, the electric circuit housing of the sampler has been modified to be detached from the sampling bottle when operating manually. Its performance has been confirmed through flume tests and a field experiment. It will serve as a valuable tool in the various fields of oceanography and environmental engineering, especially where seawater sampling synchronized at several sites and/or the information in storm period is important.

  • PDF

A Study on the Design and Power Performance of a Variable Photovoltaic Lightshelf Mounted on the Windows (창호거치 태양광발전 가변형광선반 설계 및 기초적 발전성능에 관한 연구)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.105-111
    • /
    • 2013
  • This study aims to suggest the PV lightshelf and to evaluate the power performance of the photovoltaic systems easily mounted on the windows. For the study, the suggested systems consist of two parts as fixed and movable PV modules. Also, tempered glass and polycarbonate are used on the surface protection materials for solar cells of PV lightshelf. By using polycarbonate, the weight of PV lightshelf is lighter about 20%. The field tests are performed for five days by using real size models. The voltage, current and electric powers are measured as basic performances of PV lightshelf. Also, the irradiation, brightness and module surface temperature are measured as outside conditions. As results, the power performance of tempered glass PV lightshelf shows about 11(%) higher thant that of polycarbonate PV lightshelf. And the power performance shows about 5(%) higher in a horizontal system. This results could be used to develop the effective PV lightshelf in next study.