• 제목/요약/키워드: horizontal correlation analysis

검색결과 209건 처리시간 0.029초

일반간호사의 조직 내 의사소통 유형과 직무만족 및 간호업무성과의 관계 (Relations Between the Types of Communication and, Job Satisfaction and Nursing Performance in Staff Nurses)

  • 서이아;박경민;이병숙
    • 한국보건간호학회지
    • /
    • 제17권2호
    • /
    • pp.317-332
    • /
    • 2003
  • This study attempts to investigate the relations between the types of communication, the job satisfaction. and the nursing performance of the staff nurses. The subjects of this study were the 114 nurses working in general wards, intensive care units, and the emergency rooms of the general hospital in Kyongbuk province. They were asked to answer the questionnaires as regards the types of communication and job satisfaction, and their performance of nursing, and these were evaluated by the head nurses, and their direct seniors. The data were collected for 10 days from the September 17 to 26, 2002. According to the purpose of the study, descriptive analysis, ANOVA. Pearson correlation coefficient, and stepwise multiple regression were applied for the data analysis using SPSS 10.0. The results are as follows : 1. The types of communication of staff nurses showed that the upward communication was $3.12\pm0.56$. the downward communication was $3.56\pm0.42$. the horizontal communication was $2.98\pm0.44$. and the informal communication was $2.59\pm0.49$. It showed that the most frequent communication was the downward communication. 2. In terms of the job satisfaction, there was significant difference according to the length of the period working for one ward (F=5.95, p=0.003), 3. The performance of nursing was significantly different according to the age (F=23.52, p=0.000), the working duration as a nurses (F=21.9, p=0.000), the types of nursing unit (F=5.33, p=0.002), and the working duration in present nursing unit (F=15.87, p=0.000). 4. In terms of communication type, the job satisfaction was associated with quality of the upward communication (F=6.23, p=0.003), the downward communication (F=5.78, p=0.004), and the horizontal communication (F=11.73, p=0.000) There were no association between the types of communication and the performance of nursing. 5. There was a positive correlation between the communication and the job satisfaction. And the downward communication (r=0.398) showed the greatest correlation with the job satisfaction. There was no statistically significant correlation between the communication and the performance of nursing. And the upward communication (r=-0.058) showed a negative, though not significant correlation with performance of nursing. 5. There was a positive correlation between the communication and the job satisfaction. And the downward communication (r=0.398) showed the greatest correlation with the job satisfaction. There was no statistically significant correlation between the communication and the performance of nursing. And the upward communication (r=-0.058) showed a negative. though not significant correlation with performance of nursing. 6. The stepwise multiple regression result showed that the downward communication accounts for $15.8\%$ (p=0,000) of the job satisfaction.

  • PDF

A Case Study on Heavy Rainfall Using a Wind Profiler and the Stability Index

  • Hong, Jongsu;Jeon, Junhang;Ryu, Chansu
    • 통합자연과학논문집
    • /
    • 제8권3호
    • /
    • pp.221-232
    • /
    • 2015
  • In this study, the vertical characteristics of wind were analyzed using the horizontal wind, vertical wind, and vertical wind shear, which are generated from a wind profiler during concentrated heavy rain, and the quantitative characteristics of concentrated heavy rain were analyzed using CAPE, SWEAT, and SRH, among the stability indexes. The analysis of the horizontal wind showed that 9 cases out of 10 had a low level jet of 25 kts at altitudes lower than 1.5 km, and that the precipitation varied according to the altitude and distribution of the low-level jet. The analysis of the vertical wind showed that it ascended up to about 3 km before precipitation. The analysis of the vertical wind shear showed that it increased up to a 1 km altitude before precipitation and had a strong value near 3 km during heavy rains. In the stability index analysis, CAPE, which represents thermal buoyancy, and SRH, which represents dynamic vorticity, were used for the interpretation of the period of heavy rain. As SWEAT contains dynamic upper level wind and thermal energy, it had a high correlation coefficient with concentrated-heavy-rain analysis. Through the case studies conducted on August 12-13, 2012, it was confirmed that the interpretation of the prediction of the period of heavy rain was possible when using the intensive observation data from a wind profiler and the stability index.

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio)

  • 우성식;이상현;정란;이정우;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio)

  • 우성식;정란;이정우
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

콘크리트 표면차수벽형 석괴댐 정상부 변위에 영향을 미치는 입력물성에 대한 민감도분석 (Sensitivity Analysis on Rockfill Material Parameters Influencing Crest Displacement of Concrete-Faced Rockfill Dam)

  • 하익수;서민우;신동훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.846-853
    • /
    • 2006
  • In this study, quantitative sensitivity analysis on rockfill material influencing the dam crest displacement of Concrete-Faced Rockfill Dam(CFRD) was carried out. The purpose of this study is to indicate the most important input parameter and to show the quantitative variation of displacement at the crest of CFR type dam with this input parameter. The rockfill material properties for parametric study were obtained from the results of large scale triaxial tests on 34 rockfill materials in the 22 different sites. From the statistical analysis on these data, some statistical characteristics of rockfill material properties such as property range, distribution characteristics, and correlation between the properties were investigated. based on these characteristics, 27 property combinations were constituted by Latin Hypercube sampling method. Dam crest displacements after construction, impounding, and earthquake loading were evaluated by static and dynamic numerical analysis on each combination. From the sensitivity analysis, it was found that the crest displacement of CFR type dam was absolutely affected by the shear modulus of rockfill material and the effect of friction angle of it was negligible. This relative difference of sensitivity was more outstanding in case of crest settlement than in case of crest horizontal displacement. Also, it was found that the settlement and horizontal displacement of dam crest logarithmically decreased as the shear modulus increased and the difference between the maximum value and the minimum vale amounted to about 9.5 times in case of settlement and about 10 times in case of horizontal displacement.

  • PDF

원피스 드레스의 줄무늬 시각효과에 관한 연구 (The Study on the Visual Effects of Stripe Patterns in onepiece Dress)

  • 이경희;윤정혜;박정순
    • 한국의류학회지
    • /
    • 제14권4호
    • /
    • pp.314-323
    • /
    • 1990
  • The purpose of this study is to investigate the visual effect of stripe patterns in one-piece dress. The results of the visual effects are as follows; 1. Comparision with experimental stripe patterns; experimental stripe patterns are likely to appear to be fat and wide in shape, and to be rhythmic, active, modern, unstable, not beautiful and dislike in sense. 2. The correlation between terms; there is a considerable correlation between 'the whole body looks fat 'and' the upper body looks fat'(r=0.84) when experimental stripe patterns are compared with vertical stripe pattern. When experimental stripe patterns compared with horizontal stripe patterns, there is a considerable correlation between 'rhythmic' and 'active' (r=0.90). 3. The results of factor analysis: commonly, factor 1 resulted in character of bodily shape and factor 2 resulted in sensuous charactor.

  • PDF

온도변화에 자유로운 임피던스 기반 국부 손상검색 (Temperature Effect-free Impedance-based Local Damage Detection)

  • 구기영;박승희;이종재;윤정방
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.21-26
    • /
    • 2007
  • This paper presents an impedance-based structural health monitoring (SHM) technique considering temperature effects. The temperature variation results in a significant impedance variation, particularly both horizontal and vertical shifts in the frequency domain, which may lead to erroneous diagnostic results of real structures. A new damage detection strategy has been proposed based on the correlation coefficient (CC) between the reference impedance data and a concurrent impedance data with an effective frequency shift which is defined as the shift causing the maximum correlation. The proposed technique was applied to a lab-sized steel truss bridge member under the temperature varying environment. From an experimental study, it has been demonstrated that a narrow cut inflicted artificially to the steel structure was successfully detected using the proposed SHM strategy.

  • PDF

NOAA/MUS 자료를 이용한 태풍 중심의 위치및 강도 분석 (The Analysis of Typhoon Center Location and Intensity from NOAA Satellite Microwave Data)

  • 신도식;서애숙;김용상;이미선
    • 대한원격탐사학회지
    • /
    • 제11권2호
    • /
    • pp.29-42
    • /
    • 1995
  • A typhoon center location and its intensity from the 54.96GMz channel of Microwave Sounding Unit(MSU) on board the NOAA satellite is analyzed. NOAA satellite MSU channel 3 data may delineate the development and dissipation of the upper tropospheric warm core associated with a typhoon. The typhoon warm core is related to microwave imagery of 250hPa temperature field (54.96GMz). The typhoon center intensity, surface center pressure and maximum wind speed at the eye well, correlate to horozontal Laplacian of an upper tropospheric temperature field. The typhoon center is found from the analysis of 250hPa temperature field. The excellent correlation is found between the horizontal Laplacian of an tropospheric temperature field and surface maximum wind speed, another correlation is found between the warm temperature anomaly and surface pressure anomaly.

HEAVY ELEMENT ABUNDANCES OF THE GALACTIC GLOBULAR CLUSTERS

  • Lee, See-Woo
    • 천문학회지
    • /
    • 제13권1호
    • /
    • pp.45-62
    • /
    • 1980
  • Defining a metal parameter $(Sp)_c$, which is related to the morphological parameters of C-M diagrams, we have estimated metal abundances for 97 globular clusters in our Galaxy. A correlation between absolute magnitude of the horizontal branch and metal abundance is derived, which is used for the determining distances to globular clusters whose visual magnitudes of the horizontal branch are known. The space distribution of globular clusters and the chemical evolution of the halo are examined. Our analysis suggests an initial mean gradient of metallicity to be d[Fe/H]/$dr_G$ = -0.06 $kpc^{-1}$ for the halo in galactocentric distance, $r_G$<20 kpc. Our findings also imply a slow collapse of protogalaxy.

  • PDF

인공위성을 이용한 한반도에서의 태양에너지 이용가능성 분석에 관한 연구 (A Study on the Feasibility Analysis for the Use of Solar Energy in Korea Using a Satellite)

  • 조덕기;강용혁;오정무
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.21-30
    • /
    • 2002
  • Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. For the validation. estimated solar radiation fluxes are compared with observed solar radiation fluxes at 16 sites over the Korean peninsular from January 1982 to December 2000. Estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -5.6 to +2.8% from the measured values and the yearly averaged horizontal global insolation of Korean peninsula was turned out to be $3.038kcal/m^2.day$.