• Title/Summary/Keyword: hollowness

Search Result 21, Processing Time 0.026 seconds

Development of Simple Density Measurement System for Watermelons (수박 밀도의 간편 계측시스템 개발)

  • 최규홍;이강진;최동수;김기영;손재룡
    • Journal of Biosystems Engineering
    • /
    • v.29 no.2
    • /
    • pp.167-174
    • /
    • 2004
  • Density is a physical property which contains information relating to the internal quality of fruits and vegetables, and can be used as an index for nondestructive quality evaluation. Density sorting has been employed by farmers for some agricultural products since ancient times. In this study, an automatic density measuring system based on the platform scale or water displacement method was developed for density sorting of watermelon. It consisted of water tan, load cell, net tray, electric motor, limit switch, control system and its program. The resolution of density was 0.001 g/㎤. In order to calibrate and evaluate the accuracy, the density was measured using a balloon kept in cold water. It showed 1.002 g/㎤ which almost correspond to real density of water. Test results with 6 watermelons and 3 replications showed that the standard deviations of the dens were 0.001∼0.004 g/㎤. The relationship between density and internal quality of watermelon was investigated using the system. The densities of hollow watermelons were less than 0.950 g/㎤, it was apparent that the density of the watermelon was related to the degree of hollowness. But the soluble solid contents and internal defects could not be estimated from the density.

Effectiveness of Temporal Augmentation Using a Calvarial Onlay Graft during Pterional Craniotomy

  • Kim, Yoon Soo;Yi, Hyung Suk;Kim, Han Kyu;Han, Yea Sik
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.204-209
    • /
    • 2016
  • Temporal hollowing occurs to varying degrees after pterional craniotomy. The most common cause of temporal hollowing is a bony defect of the pterional and temporal regions due to the resection of the sphenoid ridge and temporal squama for adequate exposure without overhang. The augmentation of such bony defects is important in preventing craniofacial deformities and postoperative hollowness. Temporal cranioplasty has been performed using a range of materials, such as acrylics, porous polyethylene, bone cement, titanium, muscle flaps, and prosthetic dermis. These methods are limited by the risk of damage to adjacent tissue and infection, a prolonged preparation phase, the possibility of reabsorption, and cost inefficiency. We have developed a method of temporal augmentation using a calvarial onlay graft as a single-stage neurosurgical reconstructive operation in patients requiring craniotomy. In this report, we describe the surgical details and review our institutional outcomes. The patients were divided into pterional craniotomy and onlay graft groups. Clinical temporal hollowing was assessed using a visual analog scale (VAS). Temporal soft tissue thickness was measured on preoperative and postoperative computed tomography (CT) studies. Both the VAS and CT-based assessments were compared between the groups. Our review indicated that the use of an onlay graft was associated with a lower VAS score and left-right discrepancy in the temporal contour than were observed in patients undergoing pterional craniotomy without an onlay graft.

The Correction of Lower Palpebral Bulge & Tear trough Groove by Repositioning of Orbicularis Oculi Muscle, Orbital Septum & Orbital Fat (눈둘레근육, 눈확사이막 및 지방재배치에 의한 눈꺼풀자루와 눈물받이고랑의 교정)

  • Jin, Eui Sang;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.304-310
    • /
    • 2005
  • Bulging of the lower eyelid & tear trough groove is regarded as a sign of aging. In the past, the surgical excision of the fat pad has been the mainstray of the management of lower palpebral bag in cosmetic blepharoplasty, Recently, fat pad sliding method has been introduced to make more attractive lower eyelids. We used the fat pad for covering the hollowness of the lower eye lid. And we use redundant fat pad for filling & augmentation of the lower eye lid by reflexion. Redraping of the orbicularis arc, with its accompanying midfacial fat repositioning, anatomically restores the cheek and lower lid to make more youthful contour. By redraping and fixing the orbicularis arc on the medial surface of the orbital rim, it becomes a more attractive midface and may prevent of ectropion. From August, 2002 to July, 2004 in correction of lower palpebral bulge & tear trough groove, these two technique were performed in 42 consecutive individuals (84 lower eyelid) for two-year period. Follow up ranged from 3 to 15 months. (an average of 9 months) Palpebral bulge & tear trough groove were corrected and obtained a youthful midface. Complication was rare. The advantages of these techniques are that: prevent in of secondary palpebral bulge and irregularity of lower eyelid by using of reflexed fat fad; prevent in of ectropion. Thus an attractive midface is obtained by redraping of orbicularis arc.

Correction of the Tear Trough Using Orbital Fat Graft from the Lower Lid (제거한 하안검 지방의 이식을 이용한 눈물받이 고랑의 교정)

  • You, Young Cheun;Lim, Dae Won;Yang, Won Yong;Park, Jun
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.335-340
    • /
    • 2006
  • Lower palpebral bags and tear trough grooves are the common signs of aging. Weakness of the orbital septum, atrophy of the orbicularis oculi muscle, slackness and laxity of the lower lid skin are the main causes of these aging changes. Tear trough groove with skeletonization of the lower orbital rim can not be corrected easily by the conventional lower blepharoplasty, but the augmentation of the volume, can be an effective method. Lower lids provide a well vascularized recipient site, which is vital for proper grafting of fat to occur. We treated tear trough groove with free fat graft of surgically removed orbital fat. Surgical excision of the fat pad and septal reinforcement with free fat graft below the levator labii superioris alaeque nasi muscle were performed to correct tear trough groove. This technique was performed in 29 consecutive individuals from October, 2001 to January, 2005. Palpebral bags and tear trough groove were corrected concomitantly and obtained a youthful attractive midface with no secondary hollowness of lower lid and irregularity. The overall results obtained were satisfactory without any complications. Recurrence of tear trough deformity due to grafted fat absorption was not noted during the 7 months of the follow-up period. The authors conclude that the procedure is safe and effective in selected patients.

Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty (두개골 성형술에서 석고와 신속조형모델을 이용한 간단한 Methylmethacrylate 삽입물 제작법)

  • Park, Ki Rin;Kim, Yong-Ha;Kim, Tae Gon;Lee, Jun Ho;Ha, Ju Ho
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.125-129
    • /
    • 2012
  • Purpose: Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty. Methods: A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day. Results: The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty. Conclusion: Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.

The Importance of a Conchal Bowl Element in the Fabrication of a Three-Dimensional Framework in Total Auricular Reconstruction

  • Kim, Young Soo
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.192-197
    • /
    • 2013
  • Background To construct a sophisticated three-dimensional framework, numerous modifications have been reported in the literature. However, most surgeons have paid little attention to the anatomical configuration of the concha and more to its deepness and hollowness, leading to unsatisfactory outcomes. Methods For a configuration of the concha that is definitely anatomical, the author further developed and employed the conchal bowl element, which has been used by several surgeons although the results have not been published elsewhere. The author constructed the conchal bowl element in one of three patterns according to the amount of available cartilages: one block, two-pieces, or a cymba bowl element only. A total of 20 patients underwent auricular reconstruction using a costal cartilage framework between 2009 and 2012. The 8 earliest reconstructions were performed without a conchal bowl element and the latter 12 with a conchal bowl element. The patients were followed up for more than 1 year. The aesthetic results were scored by evaluating characteristics involving the stability of the crus helicis, the conchal definition, and the smoothness of the helical curve. Results The ears reconstructed early without a conchal bowl element showed a shallow and one or two incompletely separated concha with an obliterated cymba conchal space. They also did not have a realistic or smooth curve of the helix because of an unstable crus helicis. However, ears reconstructed later with the concha bowl element showed a definite crus helicis, deep cymba conchal space, and smooth helical curve. Conclusions The construction of the conchal bowl element is simple, not time-consuming procedure. It is suggested that the conchal bowl element must be constructed and attached to the main framework for natural configuration of the reconstructed ear.

Approach to Internal Mammary Vessel without Rib Cartilage Resection in Free Abdominal Flap Breast Reconstruction (유리 복부 피판 유방재건술에서 늑연골을 절제하지 않는 Internal mammary vessel로의 접근법)

  • Eom, Jin Sup;Sun, Sang Hoon;Kim, Tae Gon;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.750-754
    • /
    • 2009
  • Purpose: The thoracodorsal vessels have been the standard recipient vessels for the majority of surgeons performing free abdominal flap breast reconstructions. Recently, the internal mammary vessels have been recommended as the first - choice recipient vessels for microvascular breast reconstruction. To approach the internal mammary vessel, 3rd or 4th rib cartilage excision is needed, but this method has some demerits - vessel injury, post operative pain and post operative chest hollowness. So, authors propose the approach method to the internal mammary vessel through intercostal space without rib cartilage resection. Methods: From November, 2008 to May, 2009, 13 patients underwent free abdominal flap breast reconstruction with approach to the internal mammary vessel through intercostal space without rib cartilage resection. Results: The mean patient age was 41.8 years, and the mean height was 159.3 cm. 11 patients underwent immediate breast reconstruction. Free DIEP flap reconstruction was performed in 7 patients, Free TRAM flap was performed in 5 patients, and Free SIEA flap was performed in 1 patient. Except 1 case, approach to the internal mammary vessel was took through 3rd intercostal space, and all width of intercostal space exceeded 1 cm. Conclusion: In the authors' experience, use of approach to the internal mammary vessels without rib cartilage resection method is safe and reliable to overcome demerits of rib cartilage resection method.

Preparation of Hollow Silica by Spray Drying of Nano Silica Particles and Its Heat Transfer Property (나노 실리카의 분무건조를 이용한 중공구 입자 제조와 실리카중공구의 열전달 특성)

  • Youn, Chan Ki;Lim, Hyung Mi;Cha, Sujin;Kim, Dae Sung;Lee, Seung-Ho
    • Korean Journal of Materials Research
    • /
    • v.22 no.10
    • /
    • pp.531-538
    • /
    • 2012
  • Hollow silica spheres were prepared by spray drying of precursor solution of colloidal silica. The precursor solution is composed of 10-20 nm colloidal silica dispersed in a water or ethanol-water mixture solvent with additives of tris hydroxymethyl aminomethane. The effect of pH and concentrations of the precursor and additives on the formation of hollow sphere particles was studied. The spray drying process parameters of the precursor feeding rate, inlet temperature, and gas flow rate are controlled to produce the hollow spherical silica. The mixed solvent of ethanol and water was preferred because it improved the hollowness of the spheres better than plain water did. It was possible to obtain hollow silica from high concentration of 14.3 wt% silica precursor with pH 3. The thermal conductivity and total solar reflectivity of the hollow silica sample was measured and compared with those values of other commercial insulating fillers of glass beads and $TiO_2$ for applications of insulating paint, in which the glass beads are representative of the low thermal conductive fillers and the $TiO_2$ is representative of infrared reflective fillers. The thermal conductivity of hollow silica was comparable to that of the glass beads and the total solar reflectivity was higher than that of $TiO_2$.

Fire Resistance of Circular Internally Confined Hollow Reinforced Concrete Column (원형 내부 구속 중공 철근콘크리트 기둥의 내화 성능)

  • Won, Deok-Hee;Han, Taek-Hee;Lee, Gyu-Sei;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.139-150
    • /
    • 2010
  • Reinforced-concrete (RC) columns are frequently designed and constructed. other types of columns includes composite types such as concrete-filled tube columns (CFT). Hollow RC columns may be effective in reducing both the self weight of columns and total amount of materials used. This is due to the fact that a hollow RC column possesses larger moment of inertia than that of solid RC columns of same cross sectional area. Despite the effectiveness the hollow RC column has not been popular because of its poor ductility performance. While the transverse reinforcements are effective in controlling the brittle failure of the outside concrete, they are not capable of resisting the failure of concrete of inner face which is in unconfined state of stress. To overcome these drawbacks, the internally confined hollow reinforced concrete (ICH RC), a new column type, was proposed in the previous researches. In this study, the fire resistance performance of the ICH RC columns was analyzed through a series of extensive heat transfer analyses using the nonlinear-material model program. Also, effect of factors such as the hollowness ratio, thickness of the concrete, and thickness of the internal tube on the fire resistance performance were extensively studied. Then the factors that enhance the fire-resistant performance of ICH RC were presented and analyzed.

Photoluminescence Characteristics of Fine-sized Gd2O3:Eu Phosphor Powders Prepared by Spray Pyrolysis (분무열분해 공정에 의해 합성된 미세 Gd2O3:Eu 형광체의 발광 특성)

  • Jung, Dae Soo;Koo, Hye Young;Lee, Sang Ho;Kang, Yun Chan
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1075-1080
    • /
    • 2008
  • Fine-sized $Gd_2O_3:Eu$ phosphor powders were prepared by post-treatment of the precursor powders with hollow shape obtained by spray pyrolysis from the spray solution with citric acid and flux material. Citric acid enabled the synthesis of fine-sized phosphor powders after post-treatment by increasing the hollowness of the precursor powders. The phosphor powders prepared from the spray solution without citric acid had several microns size. Flux materials increased the mean sizes of the phosphor powders. However, flux materials improved the photoluminescence intensities of the phosphor powders under ultraviolet. $Li_2CO_3$ as the flux material was appropriate to prepare the fine-sized $Gd_2O_3:Eu$ phosphor powders with high photoluminescence intensity. The phosphor powders below 3 wt% $Li_2CO_3$ of phosphor had submicron sizes after post-treatment temperatures of $1,050^{\circ}C$ and $1,150^{\circ}C$. The photoluminescence intensity of the phosphor powders post-treated at $1,150^{\circ}C$ was 124% of that of the phosphor powders post-treated at $1,050^{\circ}C$.