• Title/Summary/Keyword: hollow plasma

Search Result 96, Processing Time 0.03 seconds

The study on characteristics of corona ignitor for surface treatment of insulator (절연재료의 표면개질을 위한 코로나 발생기의 특성에 관한 연구)

  • ;;;;Y.Tabata;J.S Chang
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.504-508
    • /
    • 1995
  • The purpose of this research is to study on characteristics of corona ignitor which was designed for ignition of plasma, used at hard coating, surface treatment and thin film preparation, at high pressure. Corona ignitor composed of hollow type inner electrode and ring type external electrode. Though corona voltage increased with increasing distance between electrodes, corona discharge can be controlled stably. The gas flow in hollow type inner electrode and the construction between electrodes affect a length of corona flame and corona phenomenon. It is possible to ignite the . plasma, usually generated at low pressure(10 Torr), at high pressure(100 Torr) by corona ignitor.

  • PDF

Dependence of Gas Sensing Properties of Embossed TiO2 Thin Films on Links Between Hollow Hemispheres (엠보싱 TiO2 박막에서 링크 형상 제어에 따른 가스 감도 변화)

  • Moon, Hi-Gyu;Park, Hyung-Ho;Yoon, Seok-Jin;Jang, Ho-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.8
    • /
    • pp.639-645
    • /
    • 2012
  • Embossed $TiO_2$ thin films with high surface areas are achieved using soft-templates composed of monolayer polystyrene beads. The form of links between the beads in the templates is controlled by varying the $O_2$ plasma etching time on the templates, resulting in various templates with close-linked, nano-linked, and isolated beads. Room-temperature deposition of $TiO_2$ on the plasma-treated templates and calcination at $550^{\circ}C$ result in embossed films with tailored links between anatase $TiO_2$ hollow hemispheres. Although all the embossed films have similar surface areas, the sensitivity of films with nano-linked $TiO_2$ hollow hemispheres to 500 ppm CO and ethanol gases are much higher than that of films with close-linked and isolated hollow hemispheres, and the detection limits of them are as low as 0.6 ppm for CO and 0.1 ppm for ethanol. The strong correlation of sensitivity with the form of links between hollow hemispheres reveals the critical role of potential barriers formed at the links. The facile, large-scale, and on-chip fabrication of embossed $TiO_2$ films with nano-linked hollow hemispheres on Si substrate and the high sensitivity without the aid of additives give us a sustainable competitive advantage over various methods for the fabrication of highly sensitive $TiO_2$-based sensors.

A Study on Large Area Black Silicon Solar Cell Using Radio-Frequency Multi-Hollow cathode Plasma System (Radio Frequency Multi-Hollow Cathode 플라즈마 시스템을 이용한 대면적 블랙 실리콘 태양전지에 관한 연구)

  • 유진수;임동건;양계준;이준신
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.496-500
    • /
    • 2003
  • A low-cost, large area, random, maskless texturing scheme independent of crystal orientation is expected to significantly impact terrestrial photovoltaic technology. We investigated silicon surface microstructures formed by reactive ion etching (RIE) in Multi-Hollow cathode system. Desirable texturing effect has been achieved when radio-frequency (rf) power of about 20 Watt per one hollow cathode glow is applied for our RF Multi-Hollow cathode system. The black silicon etched surface shows almost zero reflectance in the visible region as well as in near IR region. The etched silicon surface is covered by columnar microstructures with diameters from 50 to 100 nm and depth of about 500 nm. We have successfully achieved 11.7% efficiency of mono-crystalline silicon solar cell and 10.2% multi-crystalline silicon solar cell.

The study of silicon etching using the high density hollow cathode plasma system

  • Yoo, Jin-Soo;Lee, Jun-Hoi;Gangopadhyay, U.;Kim, Kyung-Hae;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1038-1041
    • /
    • 2003
  • In the paper, we investigated silicon surface microstructures formed by reactive ion etching in hollow cathode system. Wet anisotropic chemical etching technique use to form random pyramidal structure on <100> silicon wafers usually is not effective in texturing of low-cost multicrystalline silicon wafers because of random orientation nature, but High density hollow cathode plasma system illustrates high deposition rate, better film crystal structure, improved etching characteristics. The etched silicon surface is covered by columnar microstructures with diameters form 50 to 100nm and depth of about 500nm. We used $SF_{6}$ and $O_{2}$ gases in HCP dry etch process. This paper demonstrates very high plasma density of $2{\times}10^{12}$ $cm^{-3}$ at a discharge current of 20 mA. Silicon etch rate of 1.3 ${\mu}s/min$. was achieved with $SF_{6}/O_{2}$ plasma conditions of total gas pressure=50 mTorr, gas flow rate=40 sccm, and rf power=200 W. Our experimental results can be used in various display systems such as thin film growth and etching for TFT-LCDs, emitter tip formations for FEDs, and bright plasma discharge for PDP applications. In this paper we directed our study to the silicon etching properties such as high etching rate, large area uniformity, low power with the high density plasma.

  • PDF

Molecular Emission Spectrometric Detection of Low Level Sulfur Using Hollow Cathode Glow Discharge

  • Koo, Il-Gyo;Lee, Woong-Moo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2004
  • A highly sensitive detecting method has been developed for determining part per billion of sulfur in $H_2S$/Ar plasma. The method is based on the excitation of Ar/$H_2S\;or\;Ar/H_2S/O_2$ mixture in hollow cathode glow discharge sustained by radiofrequency (RF) or 60 Hz AC power and the spectroscopic measurement of the intensity of emission lines from electronically excited $S_2^*\;or\;SO_2^*$ species, respectively. The RF or AC power needed for the excitation did not exceed 30 W at a gas pressure maintained at several mbar. The emission intensity from the $SO_2^*$ species showed excellent linear response to the sulfur concentration ranging from 5 ppbv, which correspond to S/N = 5, to 500 ppbv. But the intensity from the $S_2^*$ species showed a linear response to the $H_2S$ only at low flow rate under 20 sccm (mL/min) of the sample gas. Separate experiments using $SO_2$ gas as the source of sulfur demonstrated that the presence of $O_2$ in the argon plasma is essential for obtaining prominent $SO_2^*$ emission lines.

A Study on the Arc Characteristics and Weld Pool Analysis of GHTAW under the Space Environment (우주 환경에서 GHTAW 아크 특성과 용융지 해석에 관한 연구)

  • Lee, Sang-Hoon;Na, Suck-Joo
    • Journal of Welding and Joining
    • /
    • v.28 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • The purpose of this paper is to understand the behavior of GHTAW process under the space environment with the experimental and numerical analysis. Gas Hollow Tungsten Arc Welding (GHTAW) using a hollow tungsten electrode was adopted, since the ignition and discharge of a conventional GTAW process is not appropriate to the space environment due to low pressure in space. In order to clarify the phenomena of GHTAW under space environment, an investigation of thermal and physical properties of the GHTAW arc plasma was experimentally performed under low pressure conditions. Furthermore, the molten pool behavior and weldment of GHTAW were understood by CFD-based numerical analysis, based on the models of GHTA heat source, arc pressure and electromagnetic force induced by arc plasma, the characteristics of which were obtained by the captured images of a CCD camera.

Development and characteristics investigation of new soft plasma ionization(SPI) source (새로운 소프트 플라스마 이온화(SPI) 장치의 개발 및 특성관찰)

  • Lee, Hiwwon;Park, Hyunkook;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.152-158
    • /
    • 2009
  • In this study, we made a new discharge source improving previous SPI source to ionize softly organic compounds. The new SPI source consists of two electrodes as a hollow mesh cathode of half cylindrical shape and a hollow anode. We optimized the geometrical parameter of the SPI source by investigating the I-V curves at the various distance between the cathode and the anode. As the results, we found stable conditions of the soft plasma on broad range of the current and the voltage. The new SPI source attached to quadrupole mass spectrometer (QMS), and we obtained the mass spectra of dichloromethane (DCM). The fragment patterns of DCM appeared similarly with the pattern of electron ionization (EI).

Fabrication of Mesoporous Hollow TiO2 Microcapsules for Application as a DNA Separator

  • Jeon, Sang Gweon;Yang, Jin Young;Park, Keun Woo;Kim, Geon-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3583-3589
    • /
    • 2014
  • This study evaluated a simple and useful route to the synthesis of mesoporous $TiO_2$ microcapsules with a hollow macro-core structure. A hydrophilic precursor sol containing the surfactants in the hydrophobic solvents was deposited on PMMA polymer surfaces modified by non-thermal plasma to produce mesoporous shells after calcination. The surface of the PMMA polymer spheres was coated with $NH_4F$ and CTAB to control the interfacial properties and promote the subsequent deposition of inorganic sols. These hollow type mesoporous $TiO_2$ microcapsules could be applied as an efficient substrate for the immobilization of DNA oligonucleotides.

Rectal Absorption of Acetaminophen from Polyethylene Glycol and Witepsol Suppositories (아세트아미노펜의 Polyethylene glycol 및 Witepsol 좌제의 직장흡수 - 병원제제를 목적으로 한 아세트아미노펜좌제의 조제 및 유용성 검토-)

  • Lee, Hye Suk;Jin, Sun Kyung;Choi, Jung Hwa;Ku, Young Soon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.143-146
    • /
    • 1998
  • Acetaminophen (APAP) suppositories with active ingredients, i.e., polyethylene glycol (PEG), Witepsol H-15 (WH), were prepared for hospital use and investigated on their drug release characteristics and pharmacokinetics. WH was employed as oil-soluble base with an aim of reducing fragility and mucosa irritancy that are common drawbacks found in PEG suppositories. Also hollow type suppository was tried as compared with conventional type suppository. Drug release tests revealed that in most formulations, more than $80\%$ of loaded APAP were released within 20 minutes, except for APAP-WH hollow type suppositories. Significant differences in the plasma concentration profile were observed among four type suppositories. $T_{max}$ of APAP-PEG and APAP-WH suppositories were 90 and 60 minutes, respectively, in hollow types. APAP-WH hollow type suppositories demonstrated fast absorption rates of APAP as compared with those of APAP-PEG suppositories. No burst effect was observed from APAP-WH suppository in contrast to APAP conventional type suppository, whereas AUCs of all the suppositories were similar. APAP-WH hollow type suppository may be an useful dosage form for hospital use.

  • PDF