• Title/Summary/Keyword: hollow module

Search Result 122, Processing Time 0.027 seconds

Removal/Recovery of VOCs Using a Rubbery Polymeric Membrane (Rubbery 고분가 막을 이용한 휘발성 유기화학물의 제거 및 회수)

  • Cha, Jun-Seok
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.173-181
    • /
    • 1996
  • Common volatile organic compounds(VOCs) such as toluene and methanol were removed successfully from N$_{2}$ using a novel silicone-coated hollow fiber membrane module. This novel membrane is a thin film composite(TFC) and was highly efficient in removing VOCs selectively from a N$_{2}$ stream. This membrane had some innate advantages over other silicone-based membrane in that the selective barrier was ultrathin(~1 $\mu$m) and the porosity of the polypropylene substrate was high which leads to a low permeation resistance. The substram was very strongly bonded to the coating layer by plasma polymerization and can withstand a very high pressure. A small hollow fiber module having a length of 25cm and 50 fibers could remove 96~99% of toluene as well as methanol vapors when the feed flow rate was up to 60cc/min. The percent removal of VOCs were even higher when the feed inlet concentration was higher. This process is especially suitable for treating streams having a low flow rate and high VOCs concentration. The permeances of VOCs through this membrane was in the range of $4~30 \times 10^{-9}gmol/sec \cdot cm^{2}\cdot cmHg$ for both toluene and methanol, and nitrogen permeance was between $3~9 \times 10^{-10}gmol/sec \cdot cm^{2} \cdot cmHg$. High separation factor between 10~55 for toluene/N$_{2}$ and 15~125 for methanol/N$_{2}$ were obtained depending on the feed flow rate ranges and feed VOCs concentration levels.

  • PDF

Simulation on Recovery of Methane Greenhouse Gas from Biogas Using 3 Stage Membrane Modules (바이오가스로부터 온실가스 메탄 회수를 위한 3단 분리막 공정 모사)

  • Lee, Yongtaek
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.243-251
    • /
    • 2018
  • Methane is one of the important greenhouse gases and methane is the major component of the biogas. A multiple stage membrane process was developed and analysed with the numerical analysis so that the mole fraction of methane in the final product could be kept higher than 0.95 and simultaneously the recovery of methane was also maintained higher than 99% from the biogas using 3 polysulfone hollow fiber membrane modules which were properly connected. As the feed pressure of the biogas, the mole fraction of methane in the biogas and the membrane area in the membrane module are increased, the methane mole fraction of the final product are found to be increased. However, a proper membrane area in the module should be carefully selected in order to achieve the satisfactory goal of 0.95 mole fraction of methane and 99% recovery of methane from the biogas. Even if the multiple membrane process is utilized with the properly selected membrane modules, the limited operating ranges have to be applied in the following parameters : the feed pressure, the flow rate, the mole fraction of methane in the biogas to get both the target methane concentration and the recovery rate of methane.

A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System (응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

Removal of Organic Pollutants from Aqueous Solution by Hollow Fiber Module (중공사모듈에 의한 수용액으로부터 유기오염물의 제거)

  • 유홍진
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.2
    • /
    • pp.114-119
    • /
    • 2003
  • This study is to remove several organic pollutants from wastewater by non-dispersive membrane solvent extraction technique. The distribution coefficients of several solvents were determined and the experimental system was operated counter-currently and cocurrently with respect to the aqueous phase and solvent. In these experiments, as the flow rate of aqueous solution inclosed, due to being shortened contact time to solvent, the rate of removal of organic pollutants decreased and as the flow rate of solvent increased, the rate of removal increased. Meanwhile, the rate of removal of organic pollutants for the countercurrent flow system was higher than that for the occurrent flow system.

  • PDF

Separation of dissolved gases from water using synthesized gases based on exhalation characteristics

  • Heo, Pil Woo;Park, In Sub
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1347-1353
    • /
    • 2014
  • It's possible for a human to breathe under water, if dissolved oxygen is effectively used. Fish can stay under water using the gill which extracts dissolved oxygen from water. Water includes small amounts of oxygen, so a human needs larger amounts of water to acquire oxygen enough for underwater breathing. The exhalation gas from a human is another method to get higher amounts of oxygen under water. It mainly composes of oxygen, nitrogen and carbon dioxide. So, if only carbon dioxide is decreased, the exhalation gas has good characteristics for breathing of a human under water. In this paper, composition of the exhalation gas from a human was analyzed using GC. Based on these results, the synthesized gas was prepared and mixed into water which was used for experimental devices to analyze separation characteristics of dissolved gases from water. Experimental devices included a water pump, a hollow fiber membrane module and a vacuum pump. The effects of pressure and water flow on separation characteristics of synthesized gas were investigated. The compositions of gases separated from water using synthesized gas were investigated using GC. These results expect to be applied to the development of underwater breathing technology for a human.

Some Results on δ-Semiperfect Rings and δ-Supplemented Modules

  • ABDIOGLU, CIHAT;SAHINKAYA, SERAP
    • Kyungpook Mathematical Journal
    • /
    • v.55 no.2
    • /
    • pp.289-300
    • /
    • 2015
  • In [9], the author extends the definition of lifting and supplemented modules to ${\delta}$-lifting and ${\delta}$-supplemented by replacing "small submodule" with "${\delta}$-small submodule" introduced by Zhou in [13]. The aim of this paper is to show new properties of ${\delta}$-lifting and ${\delta}$-supplemented modules. Especially, we show that any finite direct sum of ${\delta}$-hollow modules is ${\delta}$-supplemented. On the other hand, the notion of amply ${\delta}$-supplemented modules is studied as a generalization of amply supplemented modules and several properties of these modules are given. We also prove that a module M is Artinian if and only if M is amply ${\delta}$-supplemented and satisfies Descending Chain Condition (DCC) on ${\delta}$-supplemented modules and on ${\delta}$-small submodules. Finally, we obtain the following result: a ring R is right Artinian if and only if R is a ${\delta}$-semiperfect ring which satisfies DCC on ${\delta}$-small right ideals of R.

Recovery of Useful Components from Rice-washing Water Using Membranes (분리막을 이용한 쌀뜨물내 유효성분의 회수)

  • 정건용;박성희
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2002
  • Membrane process was investigated to recover useful components, such as protein from rice-washing water generated in the production of the washed-rice. The filtration experiments were carried out using not only a dead-end Amicon cell to determine suitable membranes but also a hollow fiber ultrafiltration, spiral wound nanofiltration and reverse osmosis modules for home water purification. Ultrafiltration module(molecular weight cut-off : 10,000 dalton) was not suitable for recovery of useful components or protein in the rice-washing water, but nanofiltration and reverse osmosis modules showed a good performance. in the case of 250% concentration of the rice-washing water contained about 9% protein the proteins in concentrates of nanofiltration and reverse osmosis were 18% and 22%, which were about 2 and 2.4 times higher protein concentrations than those of feed, respectively.

Multi-Dimension Scaling as an exploratory tool in the analysis of an immersed membrane bioreactor

  • Bick, A.;Yang, F.;Shandalov, S.;Raveh, A.;Oron, G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.105-119
    • /
    • 2011
  • This study presents the tests of an Immersed Membrane BioReactor (IMBR) equipped with a draft tube and focuses on the influence of hydrodynamic conditions on membrane fouling in a pilot-scale using a hollow fiber membrane module of ZW-10 under ambient conditions. In this system, the cross-flow velocities across the membrane surface were induced by a cylindrical draft-tube. The relationship between cross-flow velocity and aeration strength and the influence of the cross-flow on fouling rate (under various hydrodynamic conditions) were investigated using Multi-Dimension Scaling (MDS) analysis. MDS technique is especially suitable for samples with many variables and has relatively few observations, as the data about Membrane Bio-Reactor (MBR) often is. Observations and variables are analyzed simultaneously. According to the results, a specialized form of MDS, CoPlot enables presentation of the results in a two dimensional space and when plotting variables ratio (output/input) rather than original data the efficient units can be visualized clearly. The results indicate that: (i) aeration plays an important role in IMBR performance; (ii) implementing the MDS approach with reference to the variables ratio is consequently useful to characterize performance changes for data classification.