• Title/Summary/Keyword: hollow fibers

Search Result 119, Processing Time 0.022 seconds

In Vitro Evaluation of Reused Hollow Fiber Dialyzers

  • Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.245-252
    • /
    • 1992
  • Air pressure decay (APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those reused in patients several times. C-DAK 4000 (Cordis Dow) and CF 15-11 (Baxter Travenol) reused dialyzers obtained (rom the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAK dialyzers had a larger APD($11.70{\pm}1.32$mmHg/min) compared to CF dialyzers($4.32{\pm}0.55$mmHg/min) (p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHg/min)on the reused dialyzers(2 out of 40 CF and 5 out 26 C DAK) were attributed to the possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD Is a more son sitive test than UFR test to evaluate the integrity of the fibers.

  • PDF

Preparations of Carbon Fibers from Precursor Pitches Synthesized with Coal Tar or Petroleum Residue Oil

  • Yang, Kap-Seung;Park, Young-Ok;Kim, Yong-Min;Park, Sang-Hee;Yang, Cheol-Min;Kim, Yong-Joong;Soh, Soon-Young
    • Fibers and Polymers
    • /
    • v.1 no.2
    • /
    • pp.97-102
    • /
    • 2000
  • Pitch precursors were synthesized from coal tar(CT) and pyrolysis fuel oil(PFO, petroleum residue oil) at relatively low temperature of $250^{\circ}$, in the presence of horontrifluorideidiethyletherate complex(BFDE) as a catalyst and nitrobenzene(NB) as a co-catalyst. The softening point, nitrogen content and carbon yield increased with an increase of concentration of NB. The pitch precursors with good spinnability were prepared by removing the volatile components through $N_2$ blowing. The precursor pitches were spun through a circular nozzle, stabilized at $310^{\circ}$ and finally carbonized at $1000^{\circ}$. The optically anisotropic structure formed at the absence of NB was changed into isotropic structure, showing a decrease in size of the flow domain. The hollow carbon fiber could be prepared in the process of stabilization. The results proposed that the morphology of carbon materials could be controlled by changing the concentration of catalyst and/or co-catalyst and/or stabilization condition that affect on the mobility of molecules during carbonization.

  • PDF

Optimization of Separation Process of Bioflavonoids and Dietary Fibers from Tangerine Peels using Hollow Fiber Membrane (중공사 막을 이용한 감귤 과피 bioflavonoids 분리 및 식이 섬유 회수 공정 최적화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.151-160
    • /
    • 1998
  • Tangerine peel is mostly discarded as waste in citrus processing. However, tangerine peel contains besides dietary fibers bioflavonoids such as naringin and hesperidin which act as antimicrobials and blood pressure depressants, respectively. A continuous membrane separation process was optimized for the production of bioflavonoids relative to feed flow rate, transmembrane pressure, temperature, and pH. The tangerine peel was blended with 7.5 times water volume and the extract was prefiltered through a prefiltration system. The prefiltered extract was ultrafiltered in a hollow fiber membrane system. The flux and feed flow rate didn't show any apparent correlation, but we could observe a mass-transfer controlled region of over 8 psi. When temperature increased from $9^{\circ}C\;to\;25^{\circ}C$, the flux increased about $10\;liters/m^2/min\;(LMH)$ but between $25^{\circ}C\;and\;33^{\circ}C$, the flux increased only 2 LMH. At every transmembrane pressure, the flux of pH 4.8 was the most highest and the flux at pH 3.0 was lower than that of pH 6.0, 7.0, or 9.0. Therefore, the optimum operating conditions were 49.3 L/hr. 10 psi, $25^{\circ}C$, and pH 4.8. Under the optimum conditions, the flux gradually decreased and finally reached a steady-state after 1 hr 50 min. The amount of dietary fibers in 1.0 g retentate in each separation step was analyzed and bioflavonoids concentration in each permeate was measured. The contents of total dietary fiber in the 170 mesh retentate and soluble dietary fiber in the prefiltered retentate were the highest. Naringin and hesperidin concentration in the permeate were $0.45{\sim}0.65\;mg/g\;and\;5.15{\sim}6.86\;mg/g$ respectively, being $15{\sim}22$ times and $79{\sim}93$ times higher than those in the tangerine peel. Therefore, it can be said that PM 10 hollow fiber membrane separation system may be a very effective method for the recovery of bioflavonoids from tangerine peel.

  • PDF

Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device (혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성)

  • 김기범;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.

Dissolution of Oxygen in Water by Nonporous Hollow Fiber Membrane Contactor (비다공성 분리막을 이용한 수용액 내 용존 산소 조절)

  • Lee, Yong-Taek;Jeong, Heon-Kyu;Ahn, Hyo-Seong;Song, In-Ho;Jeon, Hyun-Soo;Jeong, Dong-Jae
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.352-358
    • /
    • 2007
  • A nonporous hollow fiber membrane contactor was used to control the concentration of oxygen dissolved in an aqueous solution, which was predicted along the hollow fiber membrane using a computer simulation. The governing ordinary differential equations were derived for the occurrent flows of the feed aqueous solution and the feed gas mixture in a membrane contactor and they were numerically solved using the 5th Runge-Kutta-Verner method with a personal computer, where the program was coded utilizing a software of the Compaq Visual Fortran 6.6. It is found that the concentration of oxygen dissolved in water increases from 30 to 64 ppm as the length of the hollow fiber increases from 0.4 to 1.2 m when the membrane of fibers are equal to be 16,000; the flow rate of the feed gas is kept to be 0.536 mol/sec; its pressure is maintained to be 486 kPa; the flow rate of the water is 16.69 mol/sec. As the flow rate of the water increases from 9.26 to 26.85 mol/sec, the concentration of oxygen decreases from 40 to 20 ppm with the constant fiber length of 0.4 m. Finally, it is observed that the concentration of oxygen increases from 33 to 69 ppm as the pressure of the feed gas increases from 298 to 847 kPa.

Production of High Purity Oxygen by Combination of Membrane and PSA Methods (분리막과 PSA혼합법에 의한 고순도 산소의 제조)

  • Hwang, Sun-Tak
    • Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • There are growing needs to produce relatively high purity(99.0% or higher) oxygen at low cost. For small scale production, both pressure swing adsorption(PSA) and membrane process are competitive and less expensive or more convenient than well known cryogenic fractionation technology. A continuous membrane column(CMC) combined with a PSA oxygen generator can be employed to produce high purity oxygen continuously. The oxygen enriched gas generated by a PSA unit, with a concentration of 93~94%, is fed to the CMC that consism of three modules of poly(imide) hollow fibers. Several experiments were conducted by varying parameters, such as feed flow rate, transmembrane pressure drop, stage cut, and feed location in order to obtain a high oxygen concentration above 99.0%. A two-series unit mode was also employed with CMC operation to optimize the given membrane area.

  • PDF

Preparation of Porous Nanostructures Controlled by Electrospray

  • Nguyen, Dung The;Nah, In Wook;Kim, Kyo-Seon
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.627-631
    • /
    • 2015
  • Various solid structures were prepared by electrospray technique. In this process, liquid flows out from a capillary nozzle under a high electrical potential and is subjected to an electric field, which causes elongation of the meniscus to form a jet. In our study, by controlling the amount of polyvinyl pyrrolydone in precursor solution, the jet either disrupted into droplets for the formation of spherical particles or was stretched in the electric field for the formation of fibers. During the electrospray process, the ethanol solvent was evaporated and induced the solidification of precursors, forming solid particles. The evaporation of ethanol solvent also enhanced the mass transport of solutes from the inner core to the solid shell, which facilitated fabrication of porous and hollow structure. The network structures were also prepared by heating the collector.

Damage and Failure Detection of CFRP Using Optical Fiber Vibration Sensor (광섬유 진동센서를 이용한 탄소섬유강화 복합재료의 손상 및 파손검출)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.254-257
    • /
    • 2001
  • An intensity-based optical fiber vibration sensor is applied to detect and evaluate damages and fiber failure of composites. The optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. Vibration characteristics of the optical fiber vibration sensor are investigated. Surface mounted optical fiber vibration sensor is used in tensile and indentation test. Experimental results show that the optical fiber sensor can detect damages and fiber failure of composites correctly.

  • PDF

Experimental Investigation of the Acoustic Signal Detection Performance for an Interfermetric Fiber Optic Hydrophone (실험을 통한 간섭계형 광섬유 청음기의 음향신호 감지성능 연구)

  • 이종길;윤형규;설재수;남성현
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.931-936
    • /
    • 1997
  • Optical fiber sensor is a subject which has been attracted considerable attention in recent years. Detection of sound pressure with optical fibers positioned in the arms of a Mach-Zehnder interferometer is presented in this paper. A fiber length of the order of 150m is wounded is made by hollow cylinder type. To increase the sound signal 3${\times}3$ directional coupler is used. Fiber optic hydrophone is the underwater tank with 2kHz sound source. Finally, it is shown that the fiber optic hydeophone can stably detec 2kHz sound.

  • PDF

Expanding the Limits of Membrane-Based Gas Separation Materials

  • Koros, William J.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.09a
    • /
    • pp.21-22
    • /
    • 1995
  • Gas separation science and technology is among the most rapidly growing areas involving membrane-based processes. Nitrogen enrichment of air, hydrogen recovery from a broad array of stream types, and removal of acid gases from natural gases are typical of the applications in this field. Great progress has been made in the discovery of guidelines optimization of polymer structures with simultaneously high permeabilities and selectivities for these important gas pairs. The development of thin-skinned asymmetric hollow fibers have also provided structures with extremely high permeation fluxes. Especially in the case of O$_{2}$/N$_{2}$ separations, the rate of improvements in new polymeric materials for gas separations appears to be slowing to a halt. Evidence will be presented, however, that the practical tradeoff between membrane permeability and selectivity has not been reached.

  • PDF