• Title/Summary/Keyword: hollow core unit

Search Result 7, Processing Time 0.066 seconds

Load Distribution Factors for Hollow Core Slabs with In-situ Reinforced Concrete Joints

  • Song, Jong-Young;Kim S, Elliott;Lee, Ho;Kwak, Hyo-Gyoung
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • This paper provides the engineer with a simple design method dealing with situations arise where in-situ reinforced concrete joints are cast between hollow core units. Using finite element method, hollow core slabs with wide in-situ RC joints under point load and line loads are analysed. In addition, some important behavioural characteristics of the floor slab subjected to line and point loads are investigated. In-situ reinforced concrete joint causes reduction of load distribution for remote units because distance to the remote units from the point of load is increased, while the portion of load distribution carried by loaded unit increases. Also, it was turned out load distribution factors for point load and line loads are almost same. Finally, we suggest a simple analytical method, which can determine load distribution factors using normalized deflections by regression analysis for design purposes.

Evaluation of Structural Performance of Precast Prestressed Hollow-Core Slabs with Shear Reinforcement (전단철근이 배치된 프리캐스트 프리스트레스트 중공슬래브의 구조성능 평가)

  • Sang-Yoon Kim;Seon-Hoon Kim;Deuck-Hang Lee;Sun-Jin Han;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • This study aims to investigate the structural performance of hollow-core slab (HCS) memebers with 400 mm thickness. To this end, a total of four HCS specimens were fabricated based on the individual mold method to provide shear reinforcement, unlike the extrusion method. The key variables were chosen as the presence of topping concrete, core-filling concrete, and shear reinforcements. The crack patterns and load-displacement responses of the test specimens were analyzed in detail. Test results showed that inclined shear cracking occurred all the specimens, and that the specimen with shear reinforcement on the web of HCS unit had higher strength and ductility than the specimen without shear reinforcement. In particular, shear reinforcements placed on the web of HCS unit effectively resisted not only to vertical shear force but also to horizontal shear force between the interface of HCS unit and topping concrete. In addition, it was discovered that the method in which shear reinforcements are placed on the web of HCS unit is more effective in improving structural performance than core-filling method.

Web-shear capacity of prestressed hollow-core slab unit with consideration on the minimum shear reinforcement requirement

  • Lee, Deuck Hang;Park, Min-Kook;Oh, Jae-Yuel;Kim, Kang Su;Im, Ju-Hyeuk;Seo, Soo-Yeon
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.211-231
    • /
    • 2014
  • Prestressed hollow-core slabs (HCS) are widely used for modern lightweight precast floor structures because they are cost-efficient by reducing materials, and have excellent flexural strength and stiffness by using prestressing tendons, compared to reinforced concrete (RC) floor system. According to the recently revised ACI318-08, the web-shear capacity of HCS members exceeding 315 mm in depth without the minimum shear reinforcement should be reduced by half. It is, however, difficult to provide shear reinforcement in HCS members produced by the extrusion method due to their unique concrete casting methods, and thus, their shear design is significantly affected by the minimum shear reinforcement provision in ACI318-08. In this study, a large number of shear test data on HCS members has been collected and analyzed to examine their web-shear capacity with consideration on the minimum shear reinforcement requirement in ACI318-08. The analysis results indicates that the minimum shear reinforcement requirement for deep HCS members are too severe, and that the web-shear strength equation in ACI318-08 does not provide good estimation of shear strengths for HCS members. Thus, in this paper, a rational web-shear strength equation for HCS members was derived in a simple manner, which provides a consistent margin of safety on shear strength for the HCS members up to 500 mm deep. More shear test data would be required to apply the proposed shear strength equation for the HCS members over 500 mm in depth though.

Development of New GAIM Process for Faster Cooling and Material Reduction (빠른 냉각과 재료절감을 위한 새로운 가스성형 프로세스 개발)

  • 한성렬;박태원;곽진관;김철주;하만영;정영득
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.852-855
    • /
    • 2003
  • Gas-Assisted Injection Molding(GAIM) process, that can be used to provide a hollow shape in a molding, is a variant of the conventional injection molding process. GAIM has many advantages such as reduction of material, sink mark. warpage. and lower injection pressure. Thus, GAIM has been widely applied in the industry to make moldings with a hollow channel such as handles, TV frames and so on. On the other hand, GAIM has some disadvantages such as slow cooling time and flow marks. In the disadvantages, hot gas core causes slow cooling of a molding and the overflow. which is to prevent flow mark. is waste of materials. To solve these problems, we developed a new GAIM system that we called RGIM(Reverse Gas Injection Molding). The RGIM has two special units; one is the overflow buffer, which is used for reduction of a material, and the other tile air unit, which is used for faster cooling of a molding. We conducted an experiment and simulation to verify the efficiency of the RGIM system. Through experiments and simulation, we confirmed the effectively operating of the RGIM system and extracted the optimum process conditions.

  • PDF

Design and homogenization of metal sandwich tubes with prismatic cores

  • Zhang, Kai;Deng, Zichen;Ouyang, Huajiang;Zhou, Jiaxi
    • Structural Engineering and Mechanics
    • /
    • v.45 no.4
    • /
    • pp.439-454
    • /
    • 2013
  • Hollow cylindrical tubes with a prismatic sandwich lining designed to replace the solid cross-sections are studied in this paper. The sections are divided by a number of revolving periodic unit cells and three topologies of unit cells (Square, Triangle and Kagome) are proposed. Some types of multiple-topology designed materials are also studied. The feasibility and accuracy of a homogenization method for obtaining the equivalent parameters are investigated. As the curved elements of a unit cell are represented by straight elements in the method and the ratios of the lengths of the curved elements to the lengths of the straight elements vary with the changing number of unit cells, some errors may be introduced. The frequencies of the first five modes and responses of the complete and equivalent models under an internal static pressure and an internal step pressure are compared for investigating the scope of applications of the method. The lower bounds and upper bounds of the number of Square, Triangular and Kagome cells in the sections are obtained. It is shown that treating the multiple-topology designed materials as a separate-layer structure is more accurate than treating the structure as a whole.

An Evaluation on the Properties of the Hardened Lightweight Cement Using the Polyethylene Tube (폴리에틸렌 튜브를 혼입한 경량 시멘트 경화체의 기초물성 평가)

  • Kim, Sae-Young;Jeon, Bong-Min;Kim, Hyo-Youl;Oh, Sang-Gyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.57-60
    • /
    • 2006
  • This study proposes the physical properties of the hardened lightweight cement using the polyethylene tube and to make the fundamental data regarding a new lightweight concrete development. The aerated concrete is displaying various effects such as lightweight, insulation characteristic and it is coming to be widely applied the slab layer of apartment as an insulating material but currently the aerated concrete has many problems. Therefore, demonstrating similar property of former aerated concrete and improving the defects, developing new hardened cement is needed. In this study, we predict adopting possibility of hollow core polyethylene tube, as a material to make cement hardening containing a lot of void. So we changed the mixing ratio, a diameter and length of the polyethylene tube and improved the compressive strength and unit capacity weight of the lightweight cement hardening body. From the test results, we judge that the aerated concrete is a developmental possibility.

  • PDF

Brazier effect of single- and double-walled elastic tubes under pure bending

  • Sato, Motohiro;Ishiwata, Yuta
    • Structural Engineering and Mechanics
    • /
    • v.53 no.1
    • /
    • pp.17-26
    • /
    • 2015
  • The cross sections of hollow cylindrical tubes ovalise under a pure bending condition, and this reduces their flexural stiffness as their curvatures increase. It is important to accurately evaluate this phenomenon, known as the 'Brazier effect', to understand the bending behaviour of the systems considered. However, if the tubes are supported by an elastic medium or foundation, the ovalisation displacements of their cross sections may decrease. From this point of view, the purpose of this research is to analytically investigate the bending characteristics of single- and double-walled elastic tubes contacted by an elastic material by considering the Brazier effect. The Brazier moment, which is the maximum moment-carrying capacity of the ovalised cross section, can be calculated by introducing the strain energy per unit length of the tube in terms of the degree of ovalisation for the tube and the curvature. The total strain energy of the double-walled system is the sum of the strain energies of the outer and inner tubes and that of the compliant core. Results are comparatively presented to show the variation in the degree of ovalisation and the Brazier moment for single- and double-walled tubes.