• Title/Summary/Keyword: hip bone

Search Result 219, Processing Time 0.038 seconds

Comparison of Biomechanical Stability of Custom-made Hip Implants using Finite Element Analysis (스템 길이에 따른 환자맞춤 인공고관절의 역학적 안정성 비교)

  • Jun, Yongtae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.4
    • /
    • pp.426-432
    • /
    • 2016
  • Designing a morphologically well-fitted hip implant to a patient anatomy is desirable to improve surgical outcomes since a commercial ready-made hip implant may not well conform to the patient joint. In this study, biomechanical stability of patient-specific hip implants with two different stem lengths was compared and discussed using a 3D finite element analysis (FEA). The FEA results in this study showed that an increase in stem length brings about more the peaked von-Mises stress (PVMS) in the prosthesis and less in the femur. However the decrease in von-Mises stress in the femur causes stress shielding phenomenon that usually leads to considerable bone resorption. Although, in biomechanical stability point of view, this work recommends the use of smaller stems, the length of stem must be determined by considering both the von-Mises stress and the stress-shielding phenomenon.

Hip Protector Design Process for the Korean Elderly

  • Jeon, Eun-Jin;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.520-530
    • /
    • 2016
  • This research aims to propose an ergonomic design process for hip protector based on previous studies, existing products, multidisciplinary experts opinion, and wearing test. The elderly are more likely to suffer a hip fracture when they fall due to their physical changes in skeletal form, muscle quantity, bone density, and joint movement. A hip protector is an effective product to prevent hip fractures in the elderly but it also has a problem in that it is uncomfortable. Therefore there is a high chance that it won't be able to prevent hip fractures properly. Since the comfort of a hip protector is one of the most critical elements in preventing a hip fracture, we need to keep improving the hip protector for mobility and usability. Based on the previous studies and limitations of current hip protector products, we need to come up with an optimal design for the Korean elderly. First, knowledge has to be built relating to the ergonomic design of the hip protector considering body shape and size analysis using 3D-scan data, and biomechanical analysis on hip fracture. Second, we need to develop a design process including hip protector pattern design, and wearing evaluation with virtual system. Third, we suggest to reevaluate and verify the design procedure from impact evaluation using testing simulator, virtual evaluation of impact, to wearing comfort and usability evaluation. This design process presented in this study would be expected to contribute to the development of ergonomic hip protector which is suitable for the Korean elderly.

Transient osteoporosis of the hip with a femoral neck fracture during follow-up: a case report

  • Yusuke Tabata;Shuhei Matsui;Masabumi Miyamoto;Koichiro Omori;Yoichiro Tabata;Tokifumi Majima
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.212-217
    • /
    • 2023
  • We report a case of transient osteoporosis of the hip with a femoral neck fracture found during follow-up. A 53-year-old man presented with left hip pain without trauma. The pain did not improve after 2 weeks and he was brought to our hospital by ambulance. Magnetic resonance imaging (MRI) of the left hip joint showed diffuse edema in the bone marrow, which was identified by low signal intensity on T1-weighted images, high signal intensity on T2-weighted images, and increased signal intensity on short tau inversion recovery. This edema extended from the femoral head and neck to the intertrochanteric area. He was diagnosed with transient osteoporosis of the left hip. Rest gradually improved his pain; however, 3 weeks later, his left hip pain worsened without trauma. X-ray, computed tomography, and MRI results of the hip joint demonstrated a left femoral neck fracture, and osteosynthesis was performed. Differential diagnoses included avascular necrosis of the femoral head, infection, complex regional pain syndrome, rheumatoid arthritis, leukemia, and other cancers. Transient osteoporosis of the hip generally has a good prognosis with spontaneous remission within a few months to 1 year. However, a sufficient length of follow-up from condition onset to full recovery is necessary to avoid all probable complications such as fractures.

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.4
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

Wearing Characteristic Evaluation of Hip Protector for Hip Fracture Prevention (고관절 골절 예방을 위한 힙프로텍터 착용특성 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.1001-1007
    • /
    • 2014
  • We surveyed the wearing characteristics of hip protectors. The problems of existing hip protectors were identified and the directions for improvement were presented. The evaluation of wearing characteristics was conducted on the 100 elderly women (60 to 85 years) with 5 types of hip protector. The questionnaire was composed of history and characteristics on falling, hip protector acceptance, preference, use characteristics and improvement requirements. The result of wearing characteristic evaluation indicated that 52% of the subject experienced falling in winter. Incidents resulting from falling occurred: outdoors (74.5%), bathroom (10.9%), and kitchen (5.5%). Body parts to be protected were in several areas: 35.6% for lumbar, 26.9% for hip joint, and 15% for hip bone. Participants prefer a belt B type design at a rate of 56.9% because it provided a sense of stability by clinging to the body and upholding the waist. Belt B type was the most appropriate in terms of fit, allowance, mobility, and design except pad thickness. To reduce the risk of hip fracture, hip protector needs to be designed in consideration of user's type of fall and body shape. The pattern and size of a hip protector has to be improved in regards to the amount of discomfort. An objective evaluation is needed for the ergonomic design of a hip protector based on and analysis of 3D body image of the elderly and the shock-absorbing quality of pad.

A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM (무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구)

  • Kim, S.K.;Chae, S.W.;Choi, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF

Age-Related Bone Mineral Density, Accumulated Bone Loss Rate at Multiple Skeletal Sites in Korean Men (한국 남성의 연령에 따른 부위별 골밀도 변화 및 골 소실률)

  • Kim, Young-Ran;Lee, Tae-Yong;Lee, Ji-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3781-3788
    • /
    • 2014
  • This study examined the age-related bone mineral density (BMD), accumulated bone loss rate (ABLR) at different skeletal sites in Korean men using the data from the Korea National Health and Nutrition Examination Survey (KNHANES)(the 1st (2010), 2nd (2010) and the year at the 5th survey). The cubic regression model was found to be the best for describing the age-related changes in BMD. The lumbar spine, total hip, femoral neck, trochanter, Ward's triangle in the bone mineral density difference were analyzed by ANOVA. The peak BMD was at 20-24 years at the lumbar spine, total hip, femoral neck, trochanter, Ward's triangle, and the 75-79 years of age group had the highest Accumulated Bone Loss Rate. Therefore, intensive management will be necessary for men over 75 years, and a diagnosis of osteoporosis in Korean men should be made according to The International Society for Clinical Densitometry; ISCD.

Association between Low Hand Grip Strength and Decreased Femoral Neck Bone Mineral Density in Korean Fishery Workers (어업종사자에서 낮은 악력과 대퇴부 경부 골밀도 감소의 연관성)

  • Mi-Ji Kim;Gyeong-Ye Lee;Joo Hyun Sung;Seok Jin Hong;Ki-Soo Park
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.4
    • /
    • pp.275-284
    • /
    • 2023
  • Objectives: This study aimed to assess hand grip strength and femoral neck bone mineral density levels among Korean fishery workers and investigate their association. Methods: Hand grip strength and femoral neck bone mineral density were measured in a survey and health examination conducted in 2021 among fishery workers in a southern region of South Korea. Covariates including gender, age, education level, income level, smoking behavior, drinking behavior, family history of hip fractures, use of calcium and vitamin D supplements, hypertension, diabetes, regular exercise, and body mass index were investigated. Multiple regression analysis was employed to assess the association between hand grip strength and femoral neck bone mineral density. Results: Among 147 fishery workers, 8.16% exhibited low hand grip strength levels indicative of possible sarcopenia, and a significant association was found between low hand grip strength and decreased femoral neck bone mineral density (β = -89.14, 95% CI = -160.50, -17.78). Additionally, factors such as women gender, advanced age, family history of hip fractures, and a body mass index below 25 kg/m2 were associated with decreased femoral neck bone mineral density. In the subgroup analysis by gender, a correlation between low hand grip strength and decreased femoral neck bone mineral density was observed only in men. Conclusions: Further research is needed to explore various determinants and intervention strategies to prevent musculoskeletal disorders among fishery workers, ultimately enhancing their quality of life and well-being.

A FEM Analysis for Acetabular Component with Negative Poisson's Ratio in Total Hip Arthroplasty

  • 최재봉
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.17-23
    • /
    • 1995
  • Based on the present FEM study for negative Poisson's-ratio UHMWPE, the following conclusions seem expected. 1) Negative Poisson's-ratio UHMWPE transfers less stresses to the subchondral or peripheral iliac bone, compared to the conventional UHMWPE with Poission's-ratio. 2) Negative Poisson's-ratio cup reduces stresses in UHMWPE cup itself as well as metal backing, and subchondral bone. 3) The reduction in periacetabular mechanical stresses would significantly reduce the rate of fatigue failure and consequently reduce the incidence of aseptic loosening of the cup due to wear or bone resorption.

  • PDF