• Title/Summary/Keyword: high-temperature area

Search Result 2,579, Processing Time 0.034 seconds

Comparison of Pollen Morphology Responded by High Temperature in Adzuki Bean (Vigna angularis) and Mung Bean (Vigna radiata)

  • Hye Rang Park;Eun Ji Suh;Ok Jae Won;Jae-Sung Park;Jin Hee Seo;Won Young Han;Ki Do Park
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.150-150
    • /
    • 2022
  • Plant reproduction associated with crop yields is highly vulnerable to global climate change components such as high and cold temperatures. The objectives of this study were to determine the effects of season-high exposure to temperature treatments in pollen morphology on Adzuki bean (V. angularis) and Mung bean (V. radiate). V. angularis and V. radiata were treated at high temperatures in the high temperature gradient greenhouse designed to cause temperature deviation. The pollen shapes treated at high temperature were compared by an electron scanning microscope. As a result, it was confirmed that the number of abnormal pollens morphology at high temperature was the least in V. radiata, and V. angularis was vulnerable to high temperatures. Also, it was found that the number of abnormal pollen morphology atT4 (Con +5~6℃) varied according to the cultivars of V. angularis. Therefore, the differences in Vigna species or cultivars with thermo-tolerance in pollen morphology to high temperature are projected to occur in the changeable future climate.

  • PDF

Measurement of Kager's Triangle Area and Retrocalcaneal Surface Temperature by shoes heel height (신발 굽 높이에 따른 Kager씨 삼각의 면적과 후종족부의 표면온도 측정)

  • Jeon, Byeongkyou;Yeo, Jindong;Shin, Jungsub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.521-529
    • /
    • 2012
  • The aim of this study was to analyze radiological change of Kager's triangle area and retrocalcaneal surface temperature by shoes heel height. Area of Kager's triangle was measured by simple radiography study And PACS of INFINITI. Retrocalcaneal surface temperature were measured by DITI. Area of Kager's triangle and retrocalcaneal surface temperature were calculated for comparison and analysis, with flat shoes and high heel shoes. Area of Kager's triangle($0.88cm^2$) and retrocalcaneal surface temperature ($1.4^{\circ}C$)tends to decrease with high heel shoes. The highest and shortest of the Kager's triangle area and a surface temperature difference between flat shoes and high heel shoes, each $0.9cm^2$, $1.2cm^2$, $1.6^{\circ}C$, $0.5^{\circ}C$ and showed slight differences. The highest weight and the lowest weight of a surface area and the temperature difference between flat shoes and high heels, each $1.8cm^2$, $0.8cm^2$, $1.1^{\circ}C$, $0.2^{\circ}C$ and higher weight Kager's area and the surface temperature is decreased. The longest time and shortest time of a surface area and the temperature difference between high heels, each $0.8cm^2$, $1.4^{\circ}C$. In conclusion, Areas of Kager's triangle and retrocalcaneal surface temperature decrease with high heel shoes. If we wear high heel shoes for a long time, retrocalcaneal pain and blood flow disorder will occurs.

A Study on the Characteristic Micro-Climate in the City using Computerized Fluid Analysis and Actual Measurement (전산유체해석과 실측을 이용한 도심내 미기후 특성에 대한 연구)

  • You, Jang-Youl;Park, Min-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.35-43
    • /
    • 2023
  • Microclimate analysis was conducted through actual measurement according to land use status in urban, and CFD analysis was conducted to analyze and predict the microclimate characteristics of urban, and compared and analyzed with the actual measurement results. It was measured in high-rise areas and parks, and the temperature of the park area was 0.4 to 0.6℃ lower, and the relative humidity was 1.0 to 3.0% higher. The correlation coefficient was obtained by comparing the results of the computational fluid analysis with the results of the computational fluid analysis at the actual location located within the CFD analysis area for validation. The seasonal correlation coefficients are all higher than 0.8, so it is judged that they can be applied to microclimate analysis in urban area. The computational fluid analysis was divided into three areas (low-rise, low and high-rise, and high-rise) centered on the A2 point. On average, the low-rise area was 0.1 to 0.4% higher than the high-rise area. In the low and high-rise area and high-rise area, the pith of buildings are wide, so the airflow is smooth, so it is judged that the temperature is relatively low.

Factor Analysis of the Relation Between Land Cover Ratio of Green Spaces and Temperature (공원녹지의 토지피복비율과 기온간의 요인분석)

  • Yoon, Yong-Han;Park, Bong-Ju;Kim, Won-Tae;Park, Sun-Young
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.485-491
    • /
    • 2008
  • The present study examined the relation between land cover condition and temperature in various types of urban green spaces. The diagram of temperature distribution showed that high-temperature zones are formed around paved areas, and low temperature zone around planted areas and grassy areas. Even in planted areas where low-temperature zones were formed, temperature was different according to hierarchical structure. That is, temperature was relatively low in areas covered with arbor + sub-arbor. With regard to land cover ratio, the increase of planted areas and grassy areas had an effect on the fall of temperature and the effect was higher in order of planted areas and grassy areas. On the contrary, paved areas and bare areas had an effect on the rise of temperature. According to the results of factor analysis, in case of the highest temperature, planted area and grassy area were put together into a factor lowering temperature, paved area and temperature into a factor raising temperature, and bare area alone into a factor of low significance. In case of the lowest temperature, grassy area and bare area were put together into a factor, and the validity of the factor analysis was proved by the analysis of urban heat islands. An increase in the number of trees by height was effective in lowering temperature, and the effect was high in order to arbor and sub-arbor, and the source of coldness in planted area was tall trees.

Characteristics of Impinging Diesel Spray on the Heated Flat Wall in High Temperature and High Pressure Environments (고온.고압 환경에서 가열평판에 충돌하는 디젤분무의 특성)

  • Im, Gyeong-Hun;Lee, Bong-Su;Kim, Jong-Hyeon;Gu, Ja-Ye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.627-633
    • /
    • 2001
  • Characteristics of a diesel spray impingement with the variation of ambient temperature, wall temperature and ambient pressure were investigated through shadowgraphy method by using high speed camera. The radial penetration of spray was increased with ambient temperature and wall temperature. It is resulted from the decrease of ambient gas density caused by the increase of temperature. The height of spray was also increased with ambient temperature and wall temperature, because the height of stagnate region is noticeably increased, although height of wall jet vortex is decreased. At the same ambient pressure, the area ratio of impinging spray of room temperature environment to high temperature environment was increased, as the temperature difference between room temperature and high temperature increases. And the increment of area ratio was higher at low ambient pressure than high ambient pressure.

Analyzing Impact of the Effect of Greenbelts on the Land Surface Temperature in Seoul Metropolitan Area (수도권 그린벨트가 지표면 온도에 미치는 영향 분석)

  • Kim, Hee-Jae
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.17-31
    • /
    • 2020
  • This study aims to analyze the relations among greenbelt, urban land surface temperature empirically in order to assess the environmental effects of the greenbelt in the Seoul metropolitan area, objectively. For this purpose, this study conducts an empirical analysis of impacts of greenbelt on urban land surface temperature using a multiple-regression model. The main data employed in the analysis include real-time air pollution data, Landsat 8-OLI Landsat imagery data, KLIS data and Jip-gye-gu data. The major findings are summarized as follows. NDVI has a negative (-) correlation with the land surface temperature, and the urban temperature is high in areas with poor vegetation. The land surface temperature is low in residential or commercial areas, while the temperature is high in industrial areas. The temperature is low in green fields, open spaces, and river areas. it is found that the urban land surface temperature is low in the greenbelt zone. In the greenbelt zone, there is an effect that reduces the land surface temperature by 1% on average, as compared to that at the center of the Seoul metropolitan area. Especially, the center of the Seoul metropolitan area, in a range from 0.6% to 1.9% of the average temperature, the temperature gets lower up to approximately 3km from the greenbelt boundary.

A Study on the Evaluation Parameter of Sliding/Impact Wear in a High Temperature and Pressure Water Condition (고온고압 미끄럼/충격조건에서 마멸평가 변수 연구)

  • Lee Young-Ho;Song Ju-Sun;Kim Hyung-Kyu;Jung Youn-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.37-40
    • /
    • 2004
  • The impact/sliding wear tests have been performed in high temperature high pressure water in order to evaluate the effect of spring shape on the wear behavior of a spring supported tube for nuclear fuel fretting study. The results indicate that the tube wear volume and the size of the wear scar are closely related to each spring shape. From the analysis of the wear scar, it is possible to extract the real worn area (Aw) from the size of the wear scar (At). In addition, we found that the wear volume has a linear relation with the real worm area rather than the size of wear scar and this was only determined by each spring shape in the high temperature and pressure water condition. From the above results, it is possible to evaluate the wear resistant spring using the correlation between the variation of the real worn area and the wear behavior at each spring.

  • PDF

Heat Characteristic Analysis of Stacking Type HTS Current Lead (적층형 고온초전도 전류도입선의 열 특성 해석)

  • 두호익;임성우;홍세은;윤기웅;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.628-631
    • /
    • 2001
  • Current lead is one of the first proposed devices for the application of High Temperature-Superconductor(HTSC). The current lead provides high current for electrical machine using superconductor from room temperature. Its characteristics that is zero resistance and low heat transfer rate under critical temperature lead to research for the replacement of existing current lead with HTSC. In this paper, we investigated the temperature distributions of stacking type and rod type current lead with each cross-section area and length using Nastran program and compared each temperature distribution. It is obtained from this paper that stacking type current lead has flat temperature gradient and than rod type one and more stable operation as current lead is closely related with its cross-section area and length.

  • PDF

Relationship between Air Quality of Functional Areas and Hygiene Safety Management Performance in High School Foodservices in Gyeonggi Province (경기도 소재 고등학교 급식소의 위생·안전관리와 작업구역별 공기 품질 간의 관련성)

  • Kim, Jeonglee;Chang, Hyeja
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.4
    • /
    • pp.350-362
    • /
    • 2017
  • The study examined evaluated the sanitation management state of the high school foodservice operations, as measured by temperature, humidity and airborne bacteria concentration in functional areas and further identified their relationships. Data were collected from 26 high school foodservices in Gyeonggi Province. Statistical analyses were conducted with the SPSS program using descriptive analysis and spearman's correlation. The sanitation management performances in high school foodservice scored 86.85 out of 100 points and showed higher scores in the dimensions of preparation and storing management (17.85/20 points), operation management (17.78/20 points), and cooking utensil management (17.62/20 points), while the dimensions of cross contamination management as well as personal hygiene management needed action plans for prompt improvement. The airborne bacteria concentration was highest in the dining area (179.2 CFU/plate), and requiring action plans for improvement. The relative humidity in functional areas ranged from 66.5% in the receiving area to 74.4% (dish-washing area) and the temperature of the preparation area showed an average of $25.1^{\circ}C$ with the highest of $35.4^{\circ}C$ in the dish-washing area. In terms of the relationships among airborne bacteria, temperature, and humidity, the concentration of airborne bacteria was negatively correlated with and temperature in the dish-washing area (r= -0.693, P<0.05), and no other significances were shown in the other areas.

Correlation analysis of solar radiation and meteorological parameters on high ozone concentration (태양복사 및 기상요소의 고농도 오존형성에 대한 상관성 분석)

  • An, Jae Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.93-98
    • /
    • 2012
  • The concerns on high ozone concentration phenomenon is significantly growing in Seoul metropolitan area including the industry complex area, like Shiwha Banwol area. The aims of this research is the analysis of relationship between high concentrations of $O_3$ and solar radiation parameters in atmosphere. The understanding of the effects of solar radiation intensity, humidity, high air temperature on ozone concentration in a day is very useful to provide a direction for reducing of the high ozone concentration to a local government or a metropolitan government. The correlation analysis between maximum ozone concentration and various meteorological parameters in 2009 - 2011 carried out using IBM's SPSS program. The results showed that the mean correlations coefficient (R) between daily Ozone maximum and solar radiation resulted R = 0.64 during 2011. May - September in 10 air pollution stations. In case of correlations between daily ozone maximum and relative humidity showed negative correlation R = -0.61. The correlation analysis with mean air temperature during 1-3 PM resulted R = 0.29. This low correlation coefficient could be corrected by using of categorized data of ozone concentration. The daily maximum ozone concentration is more dependent on peak solar radiation and high air temperature during 1-3 PM than its simple daily maximum values. The results of this research would be used to develop the high ozone alert system around Seoul metropolitan area. This correlation analysis could be partially integrated to prediction of ozone peak concentration in connection with other methods like classification and regression tree(CART).