• 제목/요약/키워드: high-strength reinforcing bar

검색결과 112건 처리시간 0.02초

원전구조물 고강도철근 모듈화를 위한 적용방법 연구 (Study of application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이병수;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2013
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. This study is to introduce application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures.

  • PDF

Structural Performance of Steel Pipe Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading

  • Kim, Hyong-Kee
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2008
  • It is the purpose of this study to evaluate the structural performance of steel pipe splice for SD500 high-strength reinforcing bar, through a cyclic loading test. The experimental variables adopted in this study include the development length of rebar, the type of sleeve, and size of reinforcing bar, among others. The results of this study showed that the developed steel pipe splice system for SD500 high-strength reinforcing bar, retained the structural performance required in domestic, ACI and AIJ code. It is considered that the study result presented in this paper can be helpful in developing a reasonable design method for a steel pipe splice system for SD500 high-strength reinforcing bar.

원전구조물 고강도철근 모듈화를 위한 용접방법 성능평가 (Performance Evaluation of Welding Method for Modular of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이한우;김형섭;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.278-280
    • /
    • 2013
  • To minimize construction quantity of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop application design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are.

  • PDF

An Experimental Study on the Evaluation of Shear Performance of PVA Fiber Reinforced RC Deep Beam with High Strength Headed Rebar

  • Kim, Seunghun;Lee, Kyuseon;Lee, Yongtaeg
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.109-115
    • /
    • 2017
  • This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shear experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-span ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large difference depending on existence of shear reinforcing bar. Therefore, theoretical shear strength followed by CEB code underestimates experimental shear strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strength of bar.

고강도, 고유동 Belite 콘크리트의 부착성능 (Bond Strength of Reinforcing Steel to High Strength, High Flow Belite Concrete)

  • 김상준;조필규;이세웅;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.653-660
    • /
    • 1998
  • Bond strength of reinforcing bar to high-performance concrete using belite cement is explored using beam end test specimen. The key parameters for the bond test are slump of concrete, top bar effect, and strength of concrete in addition to concrete covers. Specimen failed in the typical brittle bond failure splitting the concrete cover as the wedging action. The test results show that the specimens with belire cement concrete show higher bond strength than those with portland cement concrete. Bond strength of the top bar is less than bond strength of bottom bar, but the top bar factor satisfies the modification factor for top reinforcement. The results also show that the bond strength is function of the square root of concrete compressive strength and cover thickness. The recently developed high-strength and high-slump concrete with belite cement performs well in terms of bond strength to reinforcing steel.

  • PDF

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

선조립공법을 활용한 원전구조물 철근모듈화 Mock-up 실험연구 (Mock-up Test for Nuclear Power Plant Rebar Modulation Applying Febrication)

  • 임상준;이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.13-14
    • /
    • 2015
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established.

  • PDF

SD500 고강도 철근용 강관 스플라이스 슬리브 철근이음 개발 및 구조성능 평가 (Development of Steel Pipe Splice Sleeve for High Strength Reinforcing Bar(SD500) and Estimation of its Structural Performance under Monotonic Loading)

  • 이상호;김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.169-180
    • /
    • 2007
  • 본 연구에서는 SD500 고강도 철근에 적합한 강관 스플라이스 슬리브를 개발한 후에 실물크기의 20개 실험체를 제작하여 가력실험을 실시하였다. 그리고 강도를 비롯한 구조성능을 철근의 정착길이, 슬리브의 타입, 철근의 규격과 같은 실험변수에 따른 영향을 분석하고, 국내기준을 비롯한 주요기준에 따라서 비교, 평가하였다. 실험 결과는 SD500 고강도 철근용으로 개발된 강관 스플라이스 슬리브 철근이음은 주요기준에서 요구하는 구조성능을 가지고 있는 것으로 확인되었고 SD500 고강도 철근용 슬리브 철근이음에 대한 구조설계 기준 확립을 위한 기술적 자료를 제시하였다.

Belite 시멘트를 이용한 고성능 콘크리트의 철근 부착성능 실험연구 (An experimental study on Bond strength of Reinforcing steel to High-performance Concrete using Belite Cement)

  • 조필규;김상준;강지훈;김영식;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.408-415
    • /
    • 1997
  • Bond strength of reinforcing bar to high-performance concrete using Belite cement is explored using beam end test specimen. The key parameters for the bond test are slump of concrete, top bar effect, and strength of concrete in addition to concrete covers. Specimen failed in the typical brittle bond failure splitting the concrete cover as the wedging action. The test results show that for the group with portland cement I using superplasticizer additional slump does not decrease the bond strength of the top bar is less than bond strength of bottom bar, but the top bar factor satisfy the modification factor for top reinforcement. The result also show that bond strength is function of square root of concrete compressive strength and cover thickness. More detailed evaluation will be conducted from the test specimen with high strength concrete using the belite cement.

  • PDF

고성능 Belite 시멘트 콘크리트의 철근 부착성능 (Bond Strength of Reinforcing Steel to High-Performance Concrete Using Belite Cement)

  • 김상준;조필규;허준;최완철
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.169-178
    • /
    • 1998
  • 고성능 belite 시멘트 콘크리트에 대한 부착특성에 대하여 코\ulcorner리트의 강도, 슬럼프, 배근위치, 피복두께 등의영향요인을 보단부시험체와 이음길이 보시험체를 통해 연구하였다. 동일한 압축강도의 1종 보통 포틀랜드 시멘트 콘크리트에 비해 부착강도는 약 10%증가하였고 압축강도 600kg/$\textrm{cm}^2$의고강도 belite 콘크리트에서 부착강도가 대체로 {{{{ SQRT { f'c} }} }}에 비례하였다. 유동성에 있어서 높은 슬럼프에 비해 ACI 318-95 규준에서 제시하는 상부근 계수 1.3이하의범위에 있었으며 이것은 고유동 belite 콘크리트가 블리이딩이나 골재분리가 적은 것으로 보여졌다. 또한 고강도 belite시멘트 콘크리트를 사용한 이음길이 보시험체에서 부착강도는 기존 예측식의 값보다다소 높게 나타났으며, 실리커흄, 플라이애쉬를 사용한 고강도 콘크리트 부착강도의 기존연구결과인 낮은 값과 차이를 보였다. 이상의 결과로 고유동, 고강도 belite 시멘트 콘크리트는 철근과의 부착성능이 다른 재료에 비해 양호한 것으로 나타났다.