• 제목/요약/키워드: high-strength concrete

검색결과 4,128건 처리시간 0.037초

고강도 콘크리트를 사용한 보-기둥 접합부의 비 선형 거동에 관한 기초적 연구 (A Fundmental Study of the Inlastic Behavior of High Strength Concrete Beam-Column Joints.)

  • 민정규;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.51-56
    • /
    • 1990
  • Six small-scale reinforced concrete beam-column joint specimens subjected to monotonic and cyclic loading were tested to investigate the effects of strength of concrete. Variables are 1)compressive strength of concrete(f' c=300, 700kg/㎠), 2)shear span to depth ratio (a/d=4.7, 2.0). The major results of this test were: 1)flexural strength of high strength concrete beam-column joint was not affected too much by the compressive strength of concrete, 2) flexural cracks emerge to inside of beam deeply for high strength concrete member.

  • PDF

고강도콘크리트를 사용한 보-기둥 접합부의 전단강도 (Shear Strength of Beam-Column eoints Using High-Strength Concrete)

  • 장극관;서대원
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.53-62
    • /
    • 2000
  • Under severe lateral loads, ductile moments-resisting reinforced concrete frames will be subjected to large loads and displacements. Thus, large deformation and shear stree are occurred at the beam-column joints which are the most critical region in ductile moments-resisting system. The purpose of this study was to investigate the shear strength of beam-column connection using high strength concrete. Four subassemblies were designed 2/3 scale of read structures and tested. The obtained results are as follows. 1) The transverse beams increase the shear resistance and ductility of joint, 2) The slab was contributed to increase of the flexural capacity of the beam, but was not contributed to increase the joint ductility under cyclic loads. 3) The shear stress factors. given by the ACI code would be modified in evaluating the shear strength of beam-column joints of frame which were constructed with high-strength concrete.

혼합재를 사용한 고강도 콘크리트의 제조와 물성에 관한 연구 (A Study on Production and Physical Properties of High-Strength Concrete with Blending Additives)

  • 정용;심용수;김원기;정재동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.15-20
    • /
    • 1991
  • High-strength concrete were produced with super-plasticizer, silica fume, fly ash and blast furnace slag powder. Topics investigated inclued mix proportion, and effects of unit weight of binder, W/C ratio, additive type on the physical properties of high-strength concrete. As the result, at 20% of silica fume, unit weight of binder 700kg/$\textrm{m}^3$ and W/C=0.24, 28days compressive strength of concrete was over 1,000kgf/$\textrm{cm}^2$. And in cases of blending with silica fume 10% and fly ash or slag 10%, it was able to produce economical high-strength concrete with 28 days strength similar to silica fume 20% only, and higher strength after 90days.

  • PDF

제지 애쉬를 사용한 고강도 혼화재 개발에 관한 연구 (Study on the Development of High Strength Admixture using Paper Sludge Ash)

  • 이재환;서형남;김창률;민경소
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.87-92
    • /
    • 1998
  • The purpose of this study is to use paper sludge ash as a material in manufacturing high strength admixture. The reactivity of paper sludge ash as iteself is low for the crystallized non-reactive $SiO_2$, but when the $SiO_2$ was removed, the phase component is mainly composed of glass phase which could react with cement hydrates. In this study, we manufactured high strength admixture using separated paper sludge ash, and examined the strength of mortar, spun concrete with and without this high strength admixture in steam curing. The strength of spun concrete with high strength admixture including paper sludge ash was more higher than that of spun concrete without admixture. As a result, it was found that paper sludge ash could be used to a pozzolanic material in manufacturing high strength admixture.

  • PDF

실리카퓸 및 메타카올린 치환률에 따른 고강도 콘크리트와 탄소섬유보강 폴리머 보강근의 부착거동 (Bond Behavior of Carbon Fiber Polymer Reinforced Polymer Rebar in High Strength Concrete with Replacement Ratio of Silica Fume and Metakaolin)

  • 박찬기;원종필;김종옥
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.51-60
    • /
    • 2008
  • This study is to relate the bond characteristics of CFRP rebar in high strength concrete incorporated with silica fume(SF) and metakaolin(MK). An direct bond test were performed to evaluate the effect of SF and MK on bond properties of high-strength concrete and CFRP rebar. The high strength concrete mix included four SF and MK mixes with 0%, 5%, 10% and 15%. Results of bond performance experiment in relation to pullout vs slip behavior of FRP rebar and high strength showed better performance of SF than MK. Also, the results showed the improved bond strength as replacement ratio of SF and MK increased. The relative bond strength in which $1.3{\sim}3.2$ of estimated values were obtained.

고온가열을 받은 고강도 콘크리트의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of High Strength of High Strength Concrete Subject to High Temperature Heating)

  • 이태규;신승봉;김영선;이승훈;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.9-12
    • /
    • 2007
  • Recently, research and development related to high strength concrete for the high rise and large scale reinforced concrete building has been actively promoted in worldwide by national and private research project. But, it is reported that violent explosive explosion would be happened when it was exposed in fire. In the existed study, a explosion in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement paste and aggregate, and causes crack by thermal stress. In case of the Europe, Japan and America, they have studied the explosion for a long time. However it would hardly study the explosion in domestic, So it is needed base on mechanical properties of fire deterioration in high strength concrete. Therefore, this study is intend as an mechanical properties of specimen to high heating by heating and load test machine and $700^{\circ}C$. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

고강도 철근콘크리트 보의 전단거동에 관한 연구 (A Study on Shear Behavior of High Strength Reinforced Concrete Beams)

  • 곽계환;박종건
    • 한국농공학회지
    • /
    • 제40권5호
    • /
    • pp.68-79
    • /
    • 1998
  • In the years, the concern about high-strength concrete which is new material has been heightened as a result of active research and development. Recently, as the building structure has been being bigger, higher, longer and more specialized, the demand of material with high-strength concrete for building has been increasing. The demand of high -strength concrete is expected to increase with expansion of usage about the complex concrete structures such as bridge structure as well as nuclear plants, underground structures, hydraulic structures and arctic area sturctures. In this research, silica-fume was used as an admixture in order to get a high-strength concrete. Water/binder ration was limited no more than 18 percent and the amount of unit cement was increased. In this study, a number of trial in concrete mix was carried out to get optimal mix design, and the target slump with $10{\pm}2cm$ was set for in-situ construction. High-strength concrete with cylinder strength of 1,200kgf/$cm^2$ in the 28-days was produced and tested. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns, fracture modes. The load versus strain and load versus deflection relations were obtained form the static test. The test results were compared with the shear strengths predicted by the equations of ACI code 318-89 and orther researchers. Based on the test results, shear strength equation of reinforced concrete beam using high strength concrete was proposed. Form an evaluation of the results of this experimental investigation, it was concluded that shear strength after diagonal tention cracking diminished with the increase in compressive strength for beams.

  • PDF

EVA 개질 고강도 콘크리트의 강도 및 수밀 특성 (Strength and Watertightness Properties of EVA Modified High Strength Concrete)

  • 김영익;성찬용
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.45-54
    • /
    • 2007
  • This study was performed to evaluate strength and watertightness properties of EVA modified high strength concrete in order to improve durability of concrete used in agricultural water utilization facilities that are in constant contact with water. Materials used were cement, coarse and fine aggregates, silica fume, EVA and AE water reducing agent. Tests for the slump, compressive and flexural strengths, absorption ratio and permeability coefficient according to curing condition (water and water+dry curing) and content ratio of EVA were performed. The slump results of EVA modified high strength concrete similarly showed in the content ratio of EVA powder less than 4% and decreased in the content ratio of EVA powder more than 6% compared to that of concrete without EVA powder. The compressive strength of EVA modified high strength concrete decreased with increasing the content ratio of EVA powder. The flexural strength of EVA modified high strength concrete increased with increasing the content ratio of EVA powder in the content ratio of EVA powder ratio less than 4% and had similar or slightly decreased in the content ratio of EVA powder more than 6% compared to that of concrete without EVA powder. The absorption ratio and permeability coefficient of EVA modified high strength concrete decreased with increasing the content ratio of EVA powder in the content ratio of EVA powder less than 4% and slightly increased in the content ratio of EVA powder more than 6%.

강섬유보강 고강도 경량콘크리트의 부착에 관한 실험적 연구 (An Experimental Study on the Bond of Steel Fiber Reinforced High-Strength Lightweight Concrete)

  • 민준수;김상우;이시학;김용부
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.613-616
    • /
    • 1999
  • The bond between reinforcing bar and concrete is a significant factor to confirm that they behave uniformly in the reinforced concrete. Thus, the studies on this field have been conducted by many researchers. But for the high strength lightweight concrete few studies have been done. In this study, the steel fiber reinforced high strength lightweight concrete developed to complement the brittleness of the high strength lightweight concrete was studied experimentally to find the local bond stress. Total 20 specimens were tested and the measured test values were compared with those calculated according to ACI 318-95 code and CEB-FIP code, respectively. The results indicate that the maximum bond stress has been influenced by increment of volume fracture of steel fiber, compressive strength and cover, Especially steel fiber caused not only increment of bond strength but also ductile behaviro.

  • PDF

고강도콘크리트 벽체부재에 접합분리 시험체를 활용한 강도관리에 관한 연구 (Compressive Strength Control of High Strength Concrete Structure Using Samples with Isolated Junction Test)

  • 기전도;김학영;김광기;백민수;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.47-50
    • /
    • 2009
  • The existing techniques used to estimate and manage the compressive strength of concrete do not include the environmental factors that influence the development of compressive strength and the compressive strength itself. Thus, it is necessary to develop a reasonable yet simple way to measure the compressive strength of concrete structures at construction sites by considering concrete's mechanical properties and curing environment. This study was conducted to propose an acrylic form and a junction isolation mold with crack-inducing boards that uses non-destructive methods to create and collect concrete test samples that are cured in the same condition as the actual concrete structures. junction isolation molds were used in high-strength and super high-strength concrete to evaluate the reliability of compressive strength evaluation on the test sample. The following were the findings of this study:

  • PDF