• 제목/요약/키워드: high-strength bolt

검색결과 164건 처리시간 0.026초

Experimental research on vertical mechanical performance of embedded through-penetrating steel-concrete composite joint in high-temperature gas-cooled reactor pebble-bed module

  • Zhang, Peiyao;Guo, Quanquan;Pang, Sen;Sun, Yunlun;Chen, Yan
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.357-373
    • /
    • 2022
  • The high-temperature gas-cooled reactor pebble-bed module project is the first commercial Generation-IV NPP(Nuclear Power Plant) in China. A new joint is used for the vertical support of RPV(Reactor Pressure Vessel). The steel corbel is integrally embedded into the reactor-cabin wall through eight asymmetrically arranged pre-stressed high-strength bolts, achieving the different path transmission of shear force and moment. The vertical monotonic loading test of two specimens is conducted. The results show that the failure mode of the joint is bolt fracture. There is no prominent yield stage in the whole loading process. The stress of bolts is linearly distributed along the height of corbel at initial loading. As the load increases, the height of neutral axis of bolts gradually decreases. The upper and lower edges of the wall opening contact the corbel plate to restrict the rotation of the corbel. During the loading, the pre-stress of some bolts decreases. The increase of the pre-stress strength ratio of bolts has no noticeable effect on the structure stiffness, but it reduces the ultimate bearing capacity of the joint. A simplified calculation model for the elastic stage of the joint is established, and the estimation results are in good agreement with the experimental results.

볼트 구멍 크기에 따른 TS 고력볼트 접합부 거동 평가 (Evaluation on the Behavior of Slip Critical Joints with TS High Strength Bolts Subjected to a Size of Bolt Holes)

  • 이현주;김강석;나환선;이강민;김현철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.136-143
    • /
    • 2011
  • 고력볼트의 현장 조립시 볼트 구멍 간의 불일치로 인하여 볼트 구멍을 확장하는 경우가 빈번하게 발생하고 있으며, 이를 위해서 외국 기준에서는 볼트 구멍 크기, 형태, 하중 방향에 따라 미끄럼하중에 대한 규정을 따로 두고 있다. 그러나 우리나라의 경우 과대구멍에 대한 시방규정이나 이에 대한 접합부 특성에 관한 연구는 미흡한 실정이다. 따라서, 접합부재 표면처리와 볼트구멍 크기의 변화가 접합부 내력에 어떠한 영향을 미치는 지를 실험을 통해 정량적으로 평가할 필요가 있다. 본 연구에서는 볼트 구멍 크기 및 형태에 따른 접합부의 미끄럼하중의 변화와 체결 후, 장기축력이완의 경향을 분석하기 위하여 160시간 및 800시간 동안 고력볼트의 축력의 변화를 측정하였다. 본 실험대상 고력볼트로 KS B 2819에 규정된 TS(Torque Shear)형 고력볼트를 사용하였다. 표준 볼트구멍 대비 그 외 볼트구멍의 미끄럼하중의 변화는 10% 미만으로 나타났으며, 장기축력이완은 직경 2.5배의 슬롯구멍에서, 2.66%로 가장 높게 나타났다.

Research on anti-seismic property of new end plate bolt connections - Wave web girder-column joint

  • Jiang, Haotian;Li, Qingning;Yan, Lei;Han, Chun;Lu, Wei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.45-61
    • /
    • 2016
  • The domestic and foreign scholars conducted many studies on mechanical properties of wave web steel beam and high-strength spiral stirrups confined concrete columns. Based on the previous research work, studies were conducted on the anti-seismic property of the end plate bolt connected wave web steel beam and high-strength spiral stirrups confined concrete column nodes applied with pre-tightening force. Four full-size node test models in two groups were designed for low-cycle repeated loading quasi-static test. Through observation of the stress, distortion, failure process and failure mode of node models, analysis was made on its load-carrying capacity, deformation performance and energy dissipation capacity, and the reliability of the new node was verified. The results showed that: under action of the beam-end stiffener, the plastic hinges on the end of wave web steel beam are displaced outward and played its role of energy dissipation capacity. The study results provided reliable theoretical basis for the engineering application of the new types of nodes.

Three-dimensional finite element simulation and application of high-strength bolts

  • Long, Liji;Yan, Yongsong;Gao, Xinlin;Kang, Haigui
    • Steel and Composite Structures
    • /
    • 제20권3호
    • /
    • pp.501-512
    • /
    • 2016
  • High-strength structural bolts have been utilized for beam-to-column connections in steel-framed structural buildings. Failure of these components may be caused by the bolt shank fracture or threads stripping-off, documented in the literature. Furthermore, these structural bolts are galvanized for corrosion resistance or quenched-and-tempered in the manufacturing process. This paper adopted the finite element simulation to demonstrate discrete mechanical performance for these bolts under tensile loading conditions, the coated and uncoated numerical model has been built up for two numerical integration methods: explicit and implicit. Experimental testing and numerical methods can fully approach the failure mechanism of these bolts and their ultimate load capacities. Comparison has also been conducted for two numerical integration methods, demonstrating that the explicit integration procedure is also suitable for solving quasi-static problems. Furthermore, by using precise bolt models in T-Stub, more accurately simulate the mechanical behavior of T-Stub, which will lay the foundation of the mechanical properties of steel bolted joints.

토크전단형 고력볼트의 토크계수 변동에 따른 체결축력 확보방안에 관한 연구 (A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts)

  • 이현주;나환선;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.

과대구멍과 슬롯구멍을 갖는 고력볼트 마찰이음부의 거동에 관한 실험적 연구 (Experimental Study on Behavior of High Strength Bolted Friction Joint with Oversized and Slotted Holes)

  • 김용환;노원경;이성희;김진호;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.683-690
    • /
    • 2008
  • 철골세우기를 할 때, 불트의 가체결은 유용하게 이용될 수 있다. 그러나 만약 부재의 제작오차나 시공현장에서의 환경 등으로 인해 부재간 볼트 구멍이 일치하지 않는다면, 시공현장에는 이를 맞추기 위해 많은 노력과 수고를 피할 수 없을 것이며, 이는 시공기간이 길어지는 원인이 될 수 있다. 이러한 문제점을 해결할 수 있는 방법으로 접합부재를 과대구멍 또는 슬롯구멍을 만드는 방법이 있고, 이는 이미 유럽과 미국에서 연구되어 설계방법까지 제시하고 있다. 그러나 국내 설계방법에는 과대구멍 및 슬롯구멍에 대해 언급되고 있지 않다. 한편 국내의 설계방법 및 건설환경은 유럽과 미국과는 다소 차이가 있다. 따라서 국내 실정에 적합한 과대구멍과 슬롯구멍에 대한 설계방법이 필요하다. 따라서 본 연구에서는 실험을 통해 고력볼트 마찰접합부의 모재가 과대구멍 및 슬롯구멍에 대한 마찰계수를 결정하고 거동을 평가하였다.

고강도(高强度) 스터드 볼트의 역학적 특성에 관한 연구 (Mechanical Properties of High Strength Shear Connector)

  • 엄철환
    • KIEAE Journal
    • /
    • 제12권5호
    • /
    • pp.93-98
    • /
    • 2012
  • The headed studs those are used extensively for steel-composite construction is specified as SS400 at the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kg/cm^2$. However, it is expected that the high strengthening and precast of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.