• Title/Summary/Keyword: high-rise apartment

Search Result 361, Processing Time 0.022 seconds

Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model (멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석)

  • Cha, Ji-Hyoung;Park, Cheol-Hun;Kim, Yeong-Ha;Baek, Chang-In;Han, Hwa-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

Evaluation of Serviceability due to Vibration of Slab (건축구조물의 슬래브 진동에 의한 사용성 평가 연구)

  • Woo, Woon-Taek;Park, Tae-Won;Chung, Lan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.225-230
    • /
    • 2000
  • Recent building structures are superior in its ability but they are light and flexible, and so have problems of vibration. In general, the serviceability of RC slabs was known to be good against vibration because of its hardness. However, recent high-rise apartment slabs are mostly light and long, the serviceability of RC slabs due to vibration could be a problem. In this paper, a basic investigation about vibration problems of RC slabs was performed. Basic information and its influence on vibrations of RC slabs were revealed. Also, its serviceability against vibration was examined. Many tests were conducted on existing building located in Chung-Nam area. As a results, damping ratio, natural frequency, acceleration amplitude and displacement amplitude which were used to examine serviceability of the RC slabs were obtained. These results on the test building proved that its serviceability conditions were satisfied to meet the code against vibration.

  • PDF

A Preliminary Study to Develop the Construction Method for Working Exterior Simultaneously with Vertical Structural Work (공동주택용 외단열 적층시공 공법 개발을 위한 기초연구)

  • Cui, Jun-Long;Kim, Taehoon;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.73-74
    • /
    • 2014
  • A construction method allowing exterior insulation working to be carried out simultaneously with vertical structural work through modification of the temporary vertical system form could be a breakthrough to invigorate exterior insulation construction in high-rise apartments. Therefore, the purpose of this study, as a preliminary study for developing such a method, was to derive significant engineering characteristics (E.C) using QFD which can reflect the users' need for E.C. Based on this result, a construction method will be developed in further research.

  • PDF

Analysis the Problems of Application and Design Proposals for Use of Terrace-House on Hilly Sites (구릉지 활용을 위한 테라스하우스 적용의 한계와 계획방향)

  • Yoon, Yong-Suk;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.235-242
    • /
    • 2005
  • The purpose of this study is to find how to use the terrace-house which can protect development thoughtless for the environment of hilly sites and make good hilly residential area. But there are some problems not to be able to apply terrace-house on hilly sites under such korean circumstances. So, to find these problems, it is analyzed different things between terrace-housing and high-rise apartment housing. This analysis finds some reasons why terrace-houses can't be applied in korea. Of these reasons to interrupt application of terrace-house, this study is to solve problem of density and to suggest the design proposals considered by habitability.

  • PDF

Development of wireless wind chill temperature measurement system (무선 체감온도 측정 시스템 개발)

  • Kim, Hyung-Pyo;Kim, Jin-Gyu;Sohn, Kyung-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.245-250
    • /
    • 2009
  • The paper presents the wireless wind chill temperature measurement system that is composed of IEEE 802.15.4 standard wireless communication devices, hot film anemometer and serial communication temperature sensor. It's sometimes very difficult for a person, who lives in a high-rise apartment, to see the outside wind chill temperature due to harsh outside weather. The wind chill temperature is calibrated from an air velocity and air temperature. IEEE 802.15.4 standard wireless communication is ZigBee compatible, and consumes low power in communication. Under the air temperature of 5 $^{\circ}C$ and air velocity ranging from 0 to 50 km/h, the experimental result of wind chill temperature shows good accuracy within 5%.

Analysis of Occupational Accident Types in the Apartment Construction Sites using Multiple Correspondence Analysis (다중 상응 분석을 통한 아파트 건설현장 업무상 재해 유형 분석)

  • Ryu, Han-Guk;Son, Seunghyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, we analyzed the safety accidents that occurred in the apartment construction site and the correlations between the victims according to the type of work accidents through multiple correspondence analysis. There is a lack of disaster-related studies on apartment construction sites, the third most frequent building type in Korea, and most of them have used survey techniques. Therefore, the exploratory data analysis was conducted in industrial accident cause data, and derived the correlation analysis between each disaster victim through multiple correspondence analysis. The results of the study are summarized in two as follows. First, as the number of heights increased due to the high rise and complexity of apartments, the fall rate and mortality rate were high. In addition, deaths are mostly caused by very few experienced workers or those with more than 10 years of experience, resulting from safety training, lack of experience, and insensitivity to safety. Second, multi-correspondence analysis showed that most safety accidents can be prevented by wearing safety equipment, and following proper work process and its safety action. The key factors derived from this study can be used for safety education, supervision, and management in apartment construction sites.

Analysis of Air Current Measurements at External Induction-Style Kitchen and Bathroom Vents (외기유인형 주방·욕실 배기구의 기류측정 분석)

  • Lee, Yong-Ho;Kim, Seong-Yong;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.76-84
    • /
    • 2012
  • This study conducted experiments to measure air currents in an experimental building according to external conditions, types of induction ducts, and types of internal sockets by applying an external induction duct comprised of inducing openings and lines and induction units to the kitchen and bathroom vents at the rooftop of a super high-rise apartment building in order to help to improve the venting performance. The study also proposed the optimization of the external induction-style kitchen and bathroom vents capable of wind power generation. (1) As for air current distribution according to vent velocity changes, it increased the venting performance of the kitchen and bathroom by 1.0m/s at vent velocity of 2.0m/s or higher and allowed for wind power generation. (2)As for air current distribution according to external velocity changes, it increased the venting performance of the kitchen and bathroom by 1.2m/s at external velocity of 2.0m/s or higher and allowed for wind power generation. (3)As for air current distribution according to wind direction changes($0{\sim}180^{\circ}$), it was favorable for higher vent velocity when the angle between the external induction duct direction and prevailing wind direction was within ${\pm}30^{\circ}$. (4)As for air current distribution according to induction duct type, the[M1] type combining the inducing openings and lines with the induction units recorded the highest improvement effects in the kitchen and bathroom venting performance by increasing vent velocity by 46%. (5)As for air current distribution according to the changing types of internal sockets where the main ducts of the kitchen and bathroom are connected to the external induction ducts, the venturi tube type[Sv] increased vent velocity by 66% based on the smoothest external inflow.

Ventilation Corridor Characteristics Analysis and Management Strategy to Improve Urban Thermal Environment - A Case Study of the Busan, South Korea - (도시 열환경 개선을 위한 바람길 특성 분석 및 관리 전략 - 부산광역시를 사례로 -)

  • Moon, Ho-Yeong;Kim, Dong-Pil;Gweon, Young-Dal;Park, Hyun-Bin
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.6
    • /
    • pp.659-668
    • /
    • 2021
  • The purpose of this study is to propose a ventilation corridor management plan to improve the thermal environment for Busan Metropolitan City. To this end, the characteristics of hot and cool spots in Busan were identified by conducting spatial statistical analysis, and thermal image data from Landsat-7 satellites and major ventilation corridors were analyzed through WRF meteorological simulation. The results showed the areas requiring thermal environment improvement among hot spot areas were Busanjin-gu, Dongnae-gu, industrial areas in Yeonje-gu and Sasang-gu, and Busan Port piers in large-scale facilities. The main ventilation corridor was identified as Geumjeongsan Mountain-Baekyangsan Mountain-Gudeoksan Mountain Valley. Based on the results, the ventilation corridor management strategy is suggested as follows. Industrial facilities and the Busan Port area are factors that increase the air temperature and worsen the thermal environment of the surrounding area. Therefore, urban and architectural plans are required to reduce the facility's temperature and consider the ventilation corridor. Areas requiring ventilation corridor management were Mandeok-dong and Sajik-dong, and they should be managed to prevent further damage to the forests. Since large-scale, high-rise apartment complexes in areas adjacent to forests interfere with the flow of cold and fresh air generated by forests, the construction of high-rise apartment complexes near Geumjeongsan Mountain with the new redevelopment of Type 3 general residential area should be avoided. It is expected that the results of this study can be used as basic data for urban planning and environmental planning in response to climate change in Busan Metropolitan City.

Assessment of 3-Dimensional Sunshine Environment Using Geographical Information System Data around Pukyong National University (부경대학교 주변 지역의 지리정보시스템 자료를 이용한 3차원 일조 환경 평가)

  • Kim, Eun-Ryoung;Park, Soo-Jin;Kim, Jae-Jin;Nam, Kyung-Yeub
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.116-131
    • /
    • 2014
  • In this study, sunshine environment in an urban area is analyzed using a numerical model which considers sunshine-duration blocking by topography and buildings. The numerical model used in this study has an improvement in the algorithm detecting sunshine duration in the model domain. The main improvement in the algorithm is to detect sunshine duration using all the surfaces of any grid cell(the previous model uses the center of any grid cell). The improvement in the algorithm gives more accurate evaluation of sunshine duration at corner surfaces of buildings. Using the improvement model and geographic information system(GIS) data, sunshine environment is analysed at an building-congested area in Busan for a week in four seasons. The results show that sunshine duration can be much changed by apartment complexes, high-rise buildings, topography in the model domain.

A Study on the Unit Block Types and Physical Characteristics of Individual Residential Area in Seoul (도시단독주택지(都市單獨住宅地) 단위(單位)블록의 유형화(類型化)와 이의 물리적(物理的) 특성(特性)에 관한 연구(硏究))

  • Jun, Byung-Kwun
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.125-136
    • /
    • 2007
  • To improve the environment of individual residential area, the uniform development of multiple dwellings through site should be avoided. As an alternative to a large scale development of the currently popular high-density and high-rise apartment buildings, which disintegrates and destroys existing communities, a new residential type that is applicable to the individual residential area should be developed. From the new residential type, even for short history of Korea of modem urban residence, a new concept of residence can be formed, changing from the concept of a temporary staying place to the concept of a stable residing place. Also, a gradual improvement that transcends time can be expected, and the present and past appearances can co-exist. This study was conducted to suggest a new residential type with unit blocks that can improve the physical structure of existing individual residential area without destroying the structure. That is, among the factors that comprise the individual residential area, this study will focus on the unit block with a medium role between a site and a mega-block, and will suggest a new concept of residential unit in order not to destroy its physical structure. The physical characteristics of the unit block will also be analyzed.