• Title/Summary/Keyword: high-pressurized jet

Search Result 13, Processing Time 0.023 seconds

A Case Study of Jet fire Estimation Model on the High Pressurized Pipeline of Natural Gas (고압가스배관의 제트화재 예측모델에 관한 사례연구)

  • Lee, Sang-Gon;Kim, Dong-Sung;Hwang, Cheol-Seung;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.371-375
    • /
    • 2007
  • Due to the benefit of QRA(Quantitative Risk Analysis) method, we can evaluate the risk, and it helps us to make our safe. We also depend to some of correlation equations to assess the jet fire at high pressurized transmission line. However, we can evaluate the risk within limitations. After comparing the current model to investigation report of natural gas transmission line accident at EL-Paso in U.S., this study concludes that more research and study are required because currently developed model cannot expect factors of the fire risk such as flame configuration.

  • PDF

Experimental Investigation on the Flow Characteristics of High Pressurized Jet with Nozzle Aspect Ratio (노즐 형상비에 따른 고압분사의 유동 특성에 관한 실험적 연구)

  • Lee, Sang-Jin;Namkung, Jung-Hwan;Rho, Byung-Joon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2031-2036
    • /
    • 2003
  • High-pressurized jet is widely using in industrial works. however, few papers studied on the performances or characteristics on that kind of nozzles. And in this study, some flow characteristics with the variation of nozzle aspect ratios such as mean velocity distributions, momentum variations along the center line have been experimentally investigated. As the results, some semi-empirical correlations of profiles of pressure and mean velocity distributions, momentum conservations with the nozzle aspect ratios are formulated. It is expected that these empirical formula can be applied for the random estimations of nozzle performances.

  • PDF

A Study on an Atomization Model of a High-Pressurized Liquid Jet with a Stability Theory (안정성 이론을 이용한 고압 분사 액체 제트의 미립화 모델에 관한 연구)

  • Kim, Hong-Seok;Seong, Nak-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.811-818
    • /
    • 2001
  • The wave characteristics for a non-reacting high-speed liquid jet were investigated using a linear stability theory. In this study, 2-D incompressible viscid momentum equation for a liquid jet was considered, and the effects of injection parameters, such as Weber number, Reynolds number, and density ratio, on the wave characteristics were investigated. With the wavelength obtained from the stability analysis, the atomization model was suggested. The droplet sizes after breakup were determined by the wavelengths of fast growing waves, and the mass of the shed droplets was determined by the breakup time derived by ORouke et al. It was found that in comparison with measurements of diesel fuel spray, the results of calculation had a similar trend of the decrease of overall SMD with the increase of Reynolds number.

Experimental Study on the Spray Characteristics for Sludge Removal Nozzle with High Pressure (슬러지 제거용 고압분사 노즐특성에 관한 실험적 연구)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.155-160
    • /
    • 2004
  • Water jet trajectories and velocity deficits from a high pressurize nozzles were experimentally observed. In this article, several parameters affecting plugging and erosion onto the steam generator tube were quantitatively analyzed. Visualization, velocity distribution, and spray growth rate with different nozzle configurations have been mainly focused using a 2-D PDPA (Phase Doppler Particle Analyzer) system. The results indicated that trajectories along the centerline regardless of their momentum has its potential core region. However, the phenomena from the peripheral part need to be meticulosly considered. Accordingly, it is evident that quantitative velocity deficits at the outer region are outstanding due to the aerodynamical drag and entrainment.

Flow characteristics of high pressurized jet with aspect ratio (형상비에 따른 고압 분사 노즐의 유동 특성 연구)

  • Roh, Byung-Joon;Jeung, Woo-Tae;Lee, Sang-Jin;Kim, Sung-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.717-722
    • /
    • 2003
  • The aspect ratio is the main parameter which governs the outer flow pattern and nozzle performance. And in this study, some flow characteristics with the variation of nozzle aspect ratios such as mean pressure distributions along the center line of the outer flow, flow coefficients and the diffusion angles have been experimentally investigated. Through the experimental analysis, the higher aspect ratio was known to decrease the jet kinetic energy because of the friction losses at the outer of nozzle. As the result, it is found that the nozzle performance depends mainly on the aspect ratio of nozzle.

  • PDF

A coupled vibration model of double-rod in cross flow for grid-to-rod fretting wear analysis

  • H. Huang;T. Liu;P. Li;Y.R. Yang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1407-1424
    • /
    • 2024
  • In Pressurized Water Reactors, most of the failed fuel rods are often observed at the periphery of the fuel assembly, especially near the core baffle. The rod vibration-induced fretting wear is a significant failure mechanism strongly correlated with the coolant and support conditions. This paper presents a coupled vibration model of double-rod to predict the grid-to-rod fretting (GTRF) wear. A motion-dependent fluid force model is used to simulate the coolant cross flow, the gap constraints with asymmetric stiffness between spring and dimple on the vibration form, and the fretting wear are discussed. The results show the effect of the coupled vibration on the deterioration of wear, providing a sound theoretical explanation of some failure phenomena observed in the previous experiment. Exploratively, we analyze the impact of the baffle jet on the GTRF wear, which indicates that the high-velocity cross-flow will significantly affect the vibration forms while sharply changing the wear behavior.

Structural Change of Supersonic Jet Due to Liquid Injection in Supersonic Backward Facing Step Flow (초음속 후향 계단 유동에서 액체 분사로 인한 초음속 제트의 구조 변화)

  • Ahn, Sang-Hoon;Han, Doo-Hee;Choi, Han-Young;Seo, Seong-Hyeon;Sung, Hong-Gye
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.9-16
    • /
    • 2019
  • The experiment on the liquid jet in crossflow in supersonic BFS (backward-facing step) flow was conducted to investigate the mixing characteristics. The working fluids are nitrogen and water. The shadow graph technique was used to visualize the flow field. Images captured by the high-speed camera were applied to analyze the flow phenomena. The liquid jet was injected at the re-circulation zone created by the supersonic jet flow. Experimental conditions are defined based on the pressure of the nitrogen gas chamber and pressurized liquid tank. In respective cases, the penetration depth of liquid jet and location of the Mach disc were observed to be proportional to the momentum ratio of gas and liquid jets.

A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment (정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구)

  • KIM, HEE JIN;JANG, KYEONG MIN;KIM, SOO HYEON;KIM, GI BEOM;JUNG, EUN SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.

Development of a Garlic Peeling System Using High-Pressure Water Jets (IV) - Structure and performance of a full-scale system in operation - (습식 마늘박피 시스템 개발 (IV) - 상업용 시스템의 구조와 성능 -)

  • Bae Y. H.;Yang K. W.;Baik S. K.;Kim J.;Chang Y. C.;Lee S. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.25-31
    • /
    • 2005
  • There are more than three hundred garlic peeling facilities in Korea and most of them use pressurized air for skin peeling operation. One of the major problems of using air for the peeling operation is the occurrence of excessive bruises on the flesh of peeled garlic which causes easy microbial contamination and shortening of the shelf lift. To reduce the occurrence of bruises during the peeling operation, a new type of garlic peeling system was developed which use pressurized water. In this system, high pressure water jets were used to separate garlic bulbs and to peel the skin of garlic cloves. Six commercial systems of this type had been developed and installed at several locations in Korea. The design and performance of the latest system according to three pressure levels were described in this paper. Peeling efficiency of the system was as high as $64.7\%$ in one cycle of peeling operation by three chambers installed in series. Incorporation of a sorting system based on machine vision and re-circulation of unpeeled and partially-peeled garlic enhanced peeling efficiency by additional $30\%$, resulting in total peeling efficiency of the final products of approximately $95\%$. Peeling capacity of the system was over 400 kg per hour.

Irrigation-suction System for Management of Deep Sternal Wound Infection after Open Heart Surgery -Four cases- (개심술 후 발생한 심부 흉골 창상감염의 세척-흡입법을 이용한 치험 -4예 보고-)

  • 김상익;오상준
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.431-435
    • /
    • 2003
  • Deep sternal wound infection (with or without acute mediastinitis) is a serious complication of open heart surgery, with high rates of associated morbidity and mortality, and prolonged hospitallization. The result of treatment largely depends on timely diagnosis and appropriate surgical management. Postoperative deep sternal wound infections in 4 cases were successfully treated with extensive debridement, pressurized jet irrigation with antibiotic solution, sternal refixation by Robicsek method, and dilute antibiotic irrigation via irrigation-suction system. We report 4 cases with review of articles.